Variability in non-invasive brain stimulation studies: Reasons and results
Open accessThe DOI matches its Crossref record; 84 of the 84 references it cites were found in a registry or an index.
Abstract
Non-invasive brain stimulation techniques (NIBS), such as Theta Burst Stimulation (TBS), Paired Associative Stimulation (PAS) and transcranial Direct Current Stimulation (tDCS), are widely used to probe plasticity in the human motor cortex (M1). Although TBS, PAS and tDCS differ in terms of physiological mechanisms responsible for experimentally-induced cortical plasticity, they all share the ability to elicit long-term potentiation (LTP) and depression (LTD) in M1. However, NIBS techniques are all affected by relevant variability in intra- and inter-subject responses. A growing number of factors contributing to NIBS variability have been recently identified and reported. In this review, we have readdressed the issue of variability in human NIBS studies. We have first briefly discussed the physiological mechanisms responsible for TBS, PAS and tDCS-induced cortical plasticity. Then, we have provided statistical measures of intra- and inter-subject variability, as calculated in previous studies. Finally, we have reported in detail known sources of variability by categorizing them into physiological, technical and statistical factors. Improving knowledge about sources of variability could lead to relevant advances in designing new tailored NIBS protocols in physiological and pathological conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hebb, D. O. (2005) · doi:10.4324/9781410612403 · Cited by 9,825
indicated, N. A. (1950) · Journal of Consulting Psychology · doi:10.1037/h0049612 · Cited by 6,923
Nitsche, M. A., & Paulus, W. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.t01-1-00633.x · Cited by 5,656 · cited 1×
“Accordingly, tDCS may work through whole-brain polarisation and is believed to induce depolarization or hyperpolarization of the resting membrane potential leading to LTP/LTD-like mechanisms [14].”
BackgroundTheta Burst Stimulation of the Human Motor Cortex
Huang, Y.-Z., Edwards, M. J., Rounis, E., Bhatia, K. P., & Rothwell, J. C. (2005) · Neuron · doi:10.1016/j.neuron.2004.12.033 · Cited by 4,158
Spike Timing–Dependent Plasticity: A Hebbian Learning Rule
Caporale, N., & Dan, Y. (2008) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.31.060407.125639 · Cited by 1,997
Evidence-based guidelines on the therapeutic use of transcranial direct current stimulation (tDCS)
Lefaucheur, J.-P., Antal, A., Ayache, S. S., Benninger, D. H., Brunelin, J., Cogiamanian, F., Cotelli, M., De Ridder, D., Ferrucci, R., Langguth, B., et al. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2016.10.087 · Cited by 1,826 · cited 1×
“International guidelines are already available for many of these factors (see for example [27]).”
BackgroundNitsche, M. A., Fricke, K., Henschke, U., Schlitterlau, A., Liebetanz, D., Lang, N., Henning, S., Tergau, F., & Paulus, W. (2003) · The Journal of Physiology · doi:10.1113/jphysiol.2003.049916 · Cited by 1,514 · cited 1×
“In particular, tDCS-induced after-effects seem to be mostly related to intracellular calcium dynamics and N-methyl-D-aspartate (NMDA) receptor activity [1,15,16].”
BackgroundInduction of plasticity in the human motor cortex by paired associative stimulation
Stefan, K. (2000) · Brain · doi:10.1093/brain/123.3.572 · Cited by 1,481 · cited 2×
“PAS at 25ms ISI increases MEP amplitudes, whereas PAS at 10ms ISI is thought to decrease MEP amplitudes for 30–60min [4].”
BackgroundSpike Timing-Dependent Plasticity of Neural Circuits
Dan, Y., & Poo, M.-M. (2004) · Neuron · doi:10.1016/j.neuron.2004.09.007 · Cited by 1,040
Bindman, L. J., Lippold, O. C. J., & Redfearn, J. W. T. (1964) · The Journal of Physiology · doi:10.1113/jphysiol.1964.sp007425 · Cited by 978
Cited by
Induction of plasticity and metaplasticity using noninvasive brain stimulation
Bhattacharya, A., Darmani, G., Udupa, K., Nankoo, J.-F., Ding, M. Y. R., & Chen, R. (2025) · Trends in Neurosciences · doi:10.1016/j.tins.2025.07.009 · Cited by 14
Metadata
- Authors
- Guerra, A., López-Alonso, V., Cheeran, B., & Suppa, A.
- Venue
- Neuroscience Letters
- Publisher
- Elsevier BV
- Published
- 2020-02
- Volume
- 719
- Pages
- 133330
- ISSN
- 0304-3940 (ISSN-L)
- OpenAlex
- W2780530080
- Cited by
- 208
- References
- 84
- FWCI
- 4.59
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Variability in non-invasive brain stimulation studies: Reasons and results. https://app.cochat.ai/papers/10.1016/j.neulet.2017.12.058
- The paper
- Guerra, A., López-Alonso, V., Cheeran, B., & Suppa, A. (2020). Variability in non-invasive brain stimulation studies: Reasons and results. Neuroscience Letters. https://doi.org/10.1016/j.neulet.2017.12.058
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.