The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Correlation-based channel selection and regularized feature optimization for MI-based BCI
Abstract
Multi-channel EEG data are usually necessary for spatial pattern identification in motor imagery (MI)-based brain computer interfaces (BCIs). To some extent, signals from some channels containing redundant information and noise may degrade BCI performance. We assume that the channels related to MI should contain common information when participants are executing the MI tasks. Based on this hypothesis, a correlation-based channel selection (CCS) method is proposed to select the channels that contained more correlated information in this study. The aim is to improve the classification performance of MI-based BCIs. Furthermore, a novel regularized common spatial pattern (RCSP) method is used to extract effective features. Finally, a support vector machine (SVM) classifier with the Radial Basis Function (RBF) kernel is trained to accurately identify the MI tasks. An experimental study is implemented on three public EEG datasets (BCI competition IV dataset 1, BCI competition III dataset IVa and BCI competition III dataset IIIa) to validate the effectiveness of the proposed methods. The results show that the CCS algorithm obtained superior classification accuracy (78% versus 56.4% for dataset1, 86.6% versus 76.5% for dataset 2 and 91.3% versus 85.1% for dataset 3) compared to the algorithm using all channels (AC), when CSP is used to extract the features. Furthermore, RCSP could further improve the classification accuracy (81.6% for dataset1, 87.4% for dataset2 and 91.9% for dataset 3), when CCS is used to select the channels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LIBSVM: A library for support vector machines
Chang, C.-C., & Lin, C.-J. (2011) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/1961189.1961199 · Cited by 40,918
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Regularized Discriminant Analysis
Friedman, J. H. (1989) · Journal of the American Statistical Association · doi:10.1080/01621459.1989.10478752 · Cited by 2,421
Review of the BCI Competition IV
Tangermann, M., Müller, K.-R., Aertsen, A., Birbaumer, N., Braun, C., Brunner, C., Leeb, R., Mehring, C., Miller, K. J., Müller-Putz, G. R., et al. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00055 · Cited by 1,288
Filter Bank Common Spatial Pattern Algorithm on BCI Competition IV Datasets 2a and 2b
Ang, K. K., Chin, Z. Y., Wang, C., Guan, C., & Zhang, H. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00039 · Cited by 1,264
Cox, D. D., & Savoy, R. L. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00049-1 · Cited by 1,053
The BCI competition III: validating alternative approaches to actual BCI problems
Blankertz, B., Muller, K.-R., Krusienski, D. J., Schalk, G., Wolpaw, J. R., Schlogl, A., Pfurtscheller, G., Millan, J. R., Schroder, M., & Birbaumer, N. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875642 · Cited by 927
Spatio-spectral filters for improving the classification of single trial EEG
Lemm, S., Blankertz, B., Curio, G., & Muller, K.-R. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851521 · Cited by 643
Support Vector Channel Selection in BCI
Lal, T. N., Schroder, M., Hinterberger, T., Weston, J., Bogdan, M., Birbaumer, N., & Scholkopf, B. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827827 · Cited by 506
Regularized Common Spatial Pattern With Aggregation for EEG Classification in Small-Sample Setting
Lu, H., Eng, H.-L., Guan, C., Plataniotis, K. N., & Venetsanopoulos, A. N. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2082540 · Cited by 309
EEG-Based Strategies to Detect Motor Imagery for Control and Rehabilitation
Ang, K. K., & Guan, C. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2646763 · Cited by 289
Composite Common Spatial Pattern for Subject-to-Subject Transfer
Kang, H., Nam, Y., & Choi, S. (2009) · IEEE Signal Processing Letters · doi:10.1109/lsp.2009.2022557 · Cited by 265
Multivariate synchronization index for frequency recognition of SSVEP-based brain–computer interface
Zhang, Y., Xu, P., Cheng, K., & Yao, D. (2014) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2013.07.018 · Cited by 233
Xu, M., Xiao, X., Wang, Y., Qi, H., Jung, T.-P., & Ming, D. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2799661 · Cited by 227
A novel hybrid BCI speller based on the incorporation of SSVEP into the P300 paradigm
Yin, E., Zhou, Z., Jiang, J., Chen, F., Liu, Y., & Hu, D. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026012 · Cited by 225
Self-citationKübler, A., Holz, E. M., Riccio, A., Zickler, C., Kaufmann, T., Kleih, S. C., Staiger-Sälzer, P., Desideri, L., Hoogerwerf, E.-J., & Mattia, D. (2014) · PLoS ONE · doi:10.1371/journal.pone.0112392 · Cited by 220
Ang, K. K., Chin, Z. Y., Zhang, H., & Guan, C. (2012) · Pattern Recognition · doi:10.1016/j.patcog.2011.04.018 · Cited by 205
Krepki, R., Blankertz, B., Curio, G., & Müller, K.-R. (2007) · Multimedia Tools and Applications · doi:10.1007/s11042-006-0094-3 · Cited by 205
Zhang, Y., Wang, Y., Jin, J., & Wang, X. (2017) · International Journal of Neural Systems · doi:10.1142/s0129065716500325 · Cited by 201
Self-citationProbabilistic Common Spatial Patterns for Multichannel EEG Analysis
Wu, W., Chen, Z., Gao, X., Li, Y., Brown, E. N., & Gao, S. (2015) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2014.2330598 · Cited by 194
Beamforming in Noninvasive Brain–Computer Interfaces
Grosse-Wentrup, M., Liefhold, C., Gramann, K., & Buss, M. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2009768 · Cited by 182
A novel BCI based on ERP components sensitive to configural processing of human faces
Zhang, Y., Zhao, Q., Jin, J., Wang, X., & Cichocki, A. S. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/2/026018 · Cited by 162
Self-citationYang, J., Singh, H., Hines, E. L., Schlaghecken, F., Iliescu, D. D., Leeson, M. S., & Stocks, N. G. (2012) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2012.02.001 · Cited by 159
Improved SFFS method for channel selection in motor imagery based BCI
Qiu, Z., Jin, J., Lam, H., Zhang, Y., Wang, X., & Cichocki, A. S. (2016) · Neurocomputing · doi:10.1016/j.neucom.2016.05.035 · Cited by 157
Self-citationTowards correlation-based time window selection method for motor imagery BCIs
Feng, J., Yin, E., Jin, J., Saab, R., Daly, I. P., Wang, X., Hu, D., & Cichocki, A. S. (2018) · Neural Networks · doi:10.1016/j.neunet.2018.02.011 · Cited by 148
Self-citationA High-Speed SSVEP-Based BCI Using Dry EEG Electrodes
Xiao, X. M., Wang, Y., Pei, W., Guo, X., Liu, Z., Wang, F., Ming, G., Zhao, H., Gui, Q., & Chen, H. (2018) · Scientific Reports · doi:10.1038/s41598-018-32283-8 · Cited by 140
A P300 Brain–Computer Interface Based on a Modification of the Mismatch Negativity Paradigm
Jin, J., Sellers, E. W., Zhou, S., Zhang, Y., Wang, X., & Cichocki, A. S. (2015) · International Journal of Neural Systems · doi:10.1142/s0129065715500112 · Cited by 138
Self-citationGamma band activity associated with BCI performance: simultaneous MEG/EEG study
Ahn, M., Ahn, S., Hong, J. H., Cho, H., Kim, K., Kim, B. S., Chang, J. W., & Jun, S. C. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00848 · Cited by 112
Voxel Selection in fMRI Data Analysis Based on Sparse Representation
Li, Y., Namburi, P., Yu, Z., Guan, C., Feng, J., & Gu, Z. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2025866 · Cited by 99
Two-Stage Frequency Recognition Method Based on Correlated Component Analysis for SSVEP-Based BCI
Zhang, Y., Yin, E., Li, F., Zhang, Y., Tanaka, T., Zhao, Q., Cui, Y., Xu, P., Yao, D., & Guo, D. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2848222 · Cited by 91
He, L., Hu, Y., Li, Y., & Li, D. (2013) · Neurocomputing · doi:10.1016/j.neucom.2013.05.005 · Cited by 90
Pan, J., Li, Y., Zhang, R., Gu, Z., & Li, F. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2253801 · Cited by 90
Kübler, A., Holz, E. M., Sellers, E. W., & Vaughan, T. M. (2015) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2014.03.036 · Cited by 77
Surfing the internet with a BCI mouse
Yu, T., Li, Y., Long, J., & Gu, Z. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/3/036012 · Cited by 75
Wavelet Common Spatial Pattern in asynchronous offline brain computer interfaces
Mousavi, E. A., Maller, J. J., Fitzgerald, P. B., & Lithgow, B. J. (2010) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2010.08.003 · Cited by 75
An improved P300 pattern in BCI to catch user’s attention
Jin, J., Zhang, H., Daly, I. P., Wang, X., & Cichocki, A. S. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6213 · Cited by 75
Self-citationUsing a hybrid neuron in physiologically inspired models of the basal ganglia
Thibeault, C. M., & Srinivasa, N. (2013) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2013.00088 · Cited by 61
Velasco-Álvarez, F., Ron-Angevín, R., da Silva‐Sauer, L., & Sancha-Ros, S. (2013) · Neurocomputing · doi:10.1016/j.neucom.2012.11.038 · Cited by 53
Zhang, D., Song, H., Xu, R., Zhou, W., Ling, Z., & Hong, B. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.12.069 · Cited by 48
Subject-specific channel selection for classification of motor imagery electroencephalographic data
Yang, Y., Kyrgyzov, O., Wiart, J., & Isabelle Bloch, A. (2013) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2013.6637856 · Cited by 36
Optimizing spatial spectral patterns jointly with channel configuration for brain–computer interface
Meng, J., Huang, G., Zhang, D., & Zhu, X. (2012) · Neurocomputing · doi:10.1016/j.neucom.2012.11.004 · Cited by 36
Xu, M., Jia, Y., Qi, H., Hu, Y. S., He, F., Zhao, X., Zhou, P., Zhang, L., Wan, B., Gao, W., et al. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.03.073 · Cited by 25
Cited by
Rashid, M., Sulaiman, N., P. P. Abdul Majeed, A., Musa, R. M., Ab. Nasir, A. F., Bari, B. S., & Khatun, S. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00025 · Cited by 506
Internal Feature Selection Method of CSP Based on L1-Norm and Dempster–Shafer Theory
Jin, J., Xiao, R., Daly, I., Miao, Y., Wang, X., & Cichocki, A. (2021) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2020.3015505 · Cited by 267
Self-citationBrain-Computer Interface: Advancement and Challenges
Mridha, M. F., Das, S. C., Kabir, M. M., Lima, A. A., Islam, M. R., & Watanobe, Y. (2021) · Sensors · doi:10.3390/s21175746 · Cited by 263
Li, Y., Liu, Y., Guo, Y.-Z., Liao, X.-F., Hu, B., & Yu, T. (2022) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2021.3071860 · Cited by 196
Metadata
- Authors
- Jin, J., Miao, Y., Daly, I., Zuo, C., Hu, D., & Cichocki, A.
- Venue
- Neural Networks
- Publisher
- Elsevier BV
- Published
- 2019-10
- Volume
- 118
- Pages
- 262-270
- ISSN
- 0893-6080 (ISSN-L)
- OpenAlex
- W2960585436
- Cited by
- 338
- References
- 42
- FWCI
- 25.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.