Physiological noise reduction for arterial spin labeling functional MRI
Abstract
Three methods for the reduction of physiological noise in arterial spin labeling (ASL) functional magnetic resonance imaging (fMRI) are presented and compared. The methods are based upon a general linear model of the ASL measurement process and on a previously described retrospective image-based method (RETROICOR) for physiological noise reduction in blood oxygenation level dependent fMRI. In the first method, the contribution of physiological noise to the interleaved control and tag images that comprise the ASL time series are assumed to be equal, while in the second method this assumption is not made. For the third method, it is assumed that physiological noise primarily impacts the perfusion time series obtained from the filtered subtraction of the control and tag images. The methods were evaluated using studies of functional activity in the visual cortex and the hippocampal region. The first and second methods significantly improved statistical performance in both brain regions, whereas the third method did not provide a significant gain. The second method provided significantly better performance than the first method in the hippocampal region, whereas the differences between methods were less pronounced in visual cortex. The improved performance of the second method in the hippocampal region appears to reflect the relatively greater effect of cardiac fluctuations in this brain region. The proposed methods should be particularly useful for ASL studies of cognitive processes where the intrinsic signal to noise ratio is typically lower than for studies of primary sensory regions.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
As fMRI scanners increase their respective field strengths, physiological noise has become a significant confound reducing the applicability and generalization of functional neuroimaging findings.
“As fMRI scanners increase their respective field strengths, physiological noise has become a significant confound reducing the applicability and generalization of functional neuroimaging findings.93”
From The neural mechanisms of mindfulness-based pain relief: a functional magnetic resonance imaging-based review and primer (2019) · cites this paper as [93]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Wise, R. G., Ide, K., Poulin, M. J., & Tracey, I. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.11.025 · Cited by 664 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
A component based noise correction method (CompCor) for BOLD and perfusion based fMRI
Behzadi, Y., Restom, K., Liau, J., & Liu, T. T. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.04.042 · Cited by 4,502 · see citing works
Self-citationZeidan, F., Emerson, N. M., Farris, S. R., Ray, J. N., Jung, Y., McHaffie, J. G., & Coghill, R. C. (2015) · The Journal of Neuroscience · doi:10.1523/jneurosci.2542-15.2015 · Cited by 369 · see citing works
Fleisher, A. S., Sherzai, A., Taylor, C., Langbaum, J. B. S., Chen, K., & Buxton, R. B. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.06.021 · Cited by 217 · see citing works
Perthen, J. E., Lansing, A. E., Liau, J., Liu, T. T., & Buxton, R. B. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.10.049 · Cited by 162 · see citing works
Self-citationThe insular cortex dynamically maps changes in cardiorespiratory interoception
Hassanpour, M. S., Simmons, W. K., Feinstein, J. S., Luo, Q., Lapidus, R. C., Bodurka, J., Paulus, M. P., & Khalsa, S. S. (2018) · Neuropsychopharmacology · doi:10.1038/npp.2017.154 · Cited by 130 · see citing works
Zeidan, F., Baumgartner, J. N., & Coghill, R. C. (2019) · PAIN Reports · doi:10.1097/pr9.0000000000000759 · Cited by 115 · see citing works
Teed, A. R., Feinstein, J. S., Puhl, M., Lapidus, R. C., Upshaw, V., Kuplicki, R. T., Bodurka, J., Ajijola, O. A., Kaye, W. H., Thompson, W. K., et al. (2022) · JAMA Psychiatry · doi:10.1001/jamapsychiatry.2021.4225 · Cited by 79 · see citing works
Hassanpour, M. S., Yan, L., Wang, D. J. J., Lapidus, R. C., Arevian, A. C., Simmons, W. K., Feusner, J. D., & Khalsa, S. S. (2016) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2016.0017 · Cited by 70 · see citing works
Attention strongly increases oxygen metabolic response to stimulus in primary visual cortex
Moradi, F., Buračas, G. T., & Buxton, R. B. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.07.078 · Cited by 42 · see citing works
Pseudocontinuous arterial spin labeling with optimized tagging efficiency
Shin, D. D., Liu, T. T., Wong, E. C., Shankaranarayanan, A., & Jung, Y. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24113 · Cited by 37 · see citing works
Self-citationPerthen, J. E., Bydder, M., Restom, K., & Liu, T. T. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2007.10.008 · Cited by 32 · see citing works
Self-citation
- Authors
- Restom, K., Behzadi, Y., & Liu, T. T.
- Affiliations
- University of California San Diego (US)
- Corresponding author
- Liu, Thomas T.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2006-07
- Volume
- 31
- Issue
- 3
- Pages
- 1104-1115
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2117805716
- Cited by
- 101
- References
- 1
- Citations by year
- 2026: 1 · 2024: 4 · 2023: 1 · 2022: 4 · 2021: 3 · 2020: 3 · 2019: 2 · 2018: 5 · 2017: 8 · 2016: 4 · 2015: 8 · 2014: 2 · 2013: 7 · 2012: 12
- FWCI
- 7.60
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- NeuroImage (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Dana Foundation
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Life Sciences › Neuroscience › Cognitive Neuroscience › Functional Brain Connectivity Studies
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
- Keywords
- arterial spin labeling, general linear model, perfusion imaging, visual cortex, hippocampus, signal-to-noise ratio, functional MRI
- MeSH terms
- Adult, Brain, Electron Spin Resonance Spectroscopy, Female, Heart Rate, Hippocampus, Humans, Image Enhancement, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Male, Pattern Recognition, Visual, Regional Blood Flow, Respiration, Visual Cortex, Artifacts, Parahippocampal Gyrus
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review