Functional and structural synergy for resolution recovery and partial volume correction in brain PET
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
PURPOSE Positron Emission Tomography (PET) has the unique capability of measuring brain function but its clinical potential is affected by low resolution and lack of morphological detail. Here we propose and evaluate a wavelet synergistic approach that combines functional and structural information from a number of sources (CT, MRI and anatomical probabilistic atlases) for the accurate quantitative recovery of radioactivity concentration in PET images. When the method is combined with anatomical probabilistic atlases, the outcome is a functional volume corrected for partial volume effects. METHODS The proposed method is based on the multiresolution property of the wavelet transform. First, the target PET image and the corresponding anatomical image (CT/MRI/atlas-based segmented MRI) are decomposed into several resolution elements. Secondly, high-resolution components of the PET image are replaced, in part, with those of the anatomical image after appropriate scaling. The amount of structural input is weighted by the relative high frequency signal content of the two modalities. The method was validated on a digital Zubal phantom and clinical data to evaluate its quantitative potential. RESULTS Simulation studies showed the expected relationship between functional recovery and the amount of correct structural detail provided, with perfect recovery achieved when true images were used as anatomical reference. The use of T1-MRI images brought significant improvements in PET image resolution. However improvements were maximized when atlas-based segmented images as anatomical references were used; these results were replicated in clinical data sets. CONCLUSION The synergistic use of functional and structural data, and the incorporation of anatomical probabilistic information in particular, generates morphologically corrected PET images of exquisite quality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bayesian-Based Iterative Method of Image Restoration*
Richardson, W. H. (1972) · Journal of the Optical Society of America · doi:10.1364/josa.62.000055 · Cited by 4,160 · cited 3×
“For comparison between SFS-RR and deconvolution approaches, two iterative likelihood deconvolution methods (Lucy– Richardson (Lucy,1974; Richardson,1972; Tohka and Reilhac, 2008) and Van-Cittert (Teo et al., 2007; Tohka and Reilhac, 2008)) were applied to the phantom data with a 4×4×4 mm3 PSF.”
An iterative technique for the rectification of observed distributions
Lucy, L. B. (1974) · The Astronomical Journal · doi:10.1086/111605 · Cited by 3,866 · cited 6×
“Recovery with Lucy–Richardson deconvolution algorithm added edges to the existing structure in the functional image providing similar variance of the recovered counts in Fig.”
InfluentialFully 3-D PET reconstruction with system matrix derived from point source measurements
Panin, V. Y., Kehren, F., Michel, C., & Casey, M. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.876171 · Cited by 536 · cited 1×
“RR techniques have also been pursued that integrate structural images and position variant PSF into the iterative reconstruction process (Ardekani et al., 1996; Baete et al., 2004; Panin et al., 2006).”
Zaidi, H., Ruest, T., Schoenahl, F., & Montandon, M.-L. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.05.031 · Cited by 108 · cited 1×
“The second is the quality of the segmentation which depends on the MRI sequence and the computational algorithm (Quarantelli et al., 2004; Rousset et al., 2008; Zaidi et al., 2006).”
Cited by
Erlandsson, K., Buvat, I., Pretorius, P. H., Thomas, B. A., & Hutton, B. F. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/21/r119 · Cited by 733
Imaging dopamine receptors in humans with [11C]-(+)-PHNO: Dissection of D3 signal and anatomy
Tziortzi, A. C., Searle, G. E., Tzimopoulou, S., Salinas, C., Beaver, J. D., Jenkinson, M., Laruelle, M., Rabiner, E. A., & Gunn, R. N. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.06.044 · Cited by 452
An early and late peak in microglial activation in Alzheimer’s disease trajectory
Fan, Z., Brooks, D. J., Okello, A., & Edison, P. (2017) · Brain · doi:10.1093/brain/aww349 · Cited by 424
Resolution modeling in PET imaging: Theory, practice, benefits, and pitfalls
Rahmim, A., Qi, J., & Sossi, V. (2013) · Medical Physics · doi:10.1118/1.4800806 · Cited by 357
Thomas, B. A., Erlandsson, K., Modat, M., Thurfjell, L., Vandenberghe, R., Ourselin, S., & Hutton, B. F. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-011-1745-9 · Cited by 316
Metadata
- Authors
- Shidahara, M., Tsoumpas, C., Hammers, A., Boussion, N., Visvikis, D., Suhara, T., Kanno, I., & Turkheimer, F. E.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2009-01
- Volume
- 44
- Issue
- 2
- Pages
- 340-348
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2074007522
- Cited by
- 94
- References
- 4
- FWCI
- 4.30
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Functional and structural synergy for resolution recovery and partial volume correction in brain PET. https://app.cochat.ai/papers/10.1016/j.neuroimage.2008.09.012
- The paper
- Shidahara, M., Tsoumpas, C., Hammers, A., Boussion, N., Visvikis, D., Suhara, T., Kanno, I., & Turkheimer, F. E. (2009). Functional and structural synergy for resolution recovery and partial volume correction in brain PET. NeuroImage. https://doi.org/10.1016/j.neuroimage.2008.09.012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.