Comparative assessment of statistical brain MR image segmentation algorithms and their impact on partial volume correction in PET
Abstract
Magnetic resonance imaging (MRI)-guided partial volume effect correction (PVC) in brain positron emission tomography (PET) is now a well-established approach to compensate the large bias in the estimate of regional radioactivity concentration, especially for small structures. The accuracy of the algorithms developed so far is, however, largely dependent on the performance of segmentation methods partitioning MRI brain data into its main classes, namely gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF). A comparative evaluation of three brain MRI segmentation algorithms using simulated and clinical brain MR data was performed, and subsequently their impact on PVC in 18F-FDG and 18F-DOPA brain PET imaging was assessed. Two algorithms, the first is bundled in the Statistical Parametric Mapping (SPM2) package while the other is the Expectation Maximization Segmentation (EMS) algorithm, incorporate a priori probability images derived from MR images of a large number of subjects. The third, here referred to as the HBSA algorithm, is a histogram-based segmentation algorithm incorporating an Expectation Maximization approach to model a four-Gaussian mixture for both global and local histograms. Simulated under different combinations of noise and intensity non-uniformity, MR brain phantoms with known true volumes for the different brain classes were generated. The algorithms' performance was checked by calculating the kappa index assessing similarities with the "ground truth" as well as multiclass type I and type II errors including misclassification rates. The impact of image segmentation algorithms on PVC was then quantified using clinical data. The segmented tissues of patients' brain MRI were given as input to the region of interest (RoI)-based geometric transfer matrix (GTM) PVC algorithm, and quantitative comparisons were made. The results of digital MRI phantom studies suggest that the use of HBSA produces the best performance for WM classification. For GM classification, it is suggested to use the EMS. Segmentation performed on clinical MRI data show quite substantial differences, especially when lesions are present. For the particular case of PVC, SPM2 and EMS algorithms show very similar results and may be used interchangeably. The use of HBSA is not recommended for PVC. The partial volume corrected activities in some regions of the brain show quite large relative differences when performing paired analysis on 2 algorithms, implying a careful choice of the segmentation algorithm for GTM-based PVC.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The accuracy of PVC algorithms is highly dependent on the degree of accuracy achieved by the MRI-PET realignment and MRI segmentation procedures.
“Thirdly, we admit that the accuracy of PVC algorithms is highly dependent on the degree of accuracy achieved by the MRI-PET realignment and MRI segmentation procedures, as assessed in many previous studies (for reviews, see [61,74,88]).”
From Voxel-based mapping of brain gray matter volume and glucose metabolism profiles in normal aging (2009) · cites this paper as [88]
Cites
Voxel-Based Morphometry—The Methods
Ashburner, J., & Friston, K. J. (2000) · NeuroImage · doi:10.1006/nimg.2000.0582 · Cited by 8,676 · see citing works
Ashburner, J., & Friston, K. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.02.018 · Cited by 7,507 · see citing works
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547 · see citing works
Comparing methods of measurement: why plotting difference against standard method is misleading
Bland, J. M., & Altman, D. G. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91748-9 · Cited by 2,343 · see citing works
Design and construction of a realistic digital brain phantom
Collins, D. L., Zijdenbos, A. P., Kollokian, V., Sled, J. G., Kabani, N. J., Holmes, C. J., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.712135 · Cited by 1,825 · see citing works
Quantitation in Positron Emission Computed Tomography
Hoffman, E. J., Huang, S., & Phelps, M. E. (1979) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197906000-00001 · Cited by 1,145 · see citing works
A survey on evaluation methods for image segmentation
Zhang, Y. J. (1996) · Pattern Recognition · doi:10.1016/0031-3203(95)00169-7 · Cited by 1,060 · see citing works
Automated model-based tissue classification of MR images of the brain
Van Leemput, K., Maes, F., Vandermeulen, D., & Suetens, P. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811270 · Cited by 1,024 · see citing works
Automated Image Registration: II. Intersubject Validation of Linear and Nonlinear Models
Woods, R. P., Grafton, S. T., Watson, J. D. G., Sicotte, N. L., & Mazziotta, J. C. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199801000-00028 · Cited by 993 · see citing works
Magnetic Resonance Image Tissue Classification Using a Partial Volume Model
Shattuck, D. W., Sandor-Leahy, S. R., Schaper, K. A., Rottenberg, D. A., & Leahy, R. M. (2001) · NeuroImage · doi:10.1006/nimg.2000.0730 · Cited by 951 · see citing works
Multimodal Image Coregistration and Partitioning—A Unified Framework
Ashburner, J., & Friston, K. J. (1997) · NeuroImage · doi:10.1006/nimg.1997.0290 · Cited by 932 · see citing works
Correction for partial volume effects in PET: principle and validation.
ROUSSET, O. G., Ma, Y., & Evans, A. C. (1998) · PubMed · Cited by 919 · see citing works
Müller‐Gärtner, H. W., Links, J. M., Prince, J. L., Bryan, R. N., McVeigh, E. R., Leal, J. P., Davatzikos, C. A., & Frost, J. J. (1992) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1992.81 · Cited by 756 · see citing works
Improved Watershed Transform for Medical Image Segmentation Using Prior Information
Grau, V., Mewes, A. U. J., Alcañíz, M., Kikinis, R., & Warfield, S. K. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.824224 · Cited by 730 · see citing works
MRI simulation-based evaluation of image-processing and classification methods
Kwan, R., Evans, A. C., & Pike, G. B. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.816072 · Cited by 714 · see citing works
MRI segmentation: Methods and applications
Clarke, L. P., Velthuizen, R. P., Camacho, M. A., Heine, J., Vaidyanathan, M., Hall, L., Thatcher, R. W., & Silbiger, M. L. (1995) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(94)00124-l · Cited by 697 · see citing works
Automated model-based bias field correction of MR images of the brain
Leemput, K. V., Maes, F., Vandermeulen, D., & Suetens, P. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811268 · Cited by 581 · see citing works
Analysis of Emission Tomographic Scan Data: Limitations Imposed by Resolution and Background
KESSLER, R. M., Ellis, J. R., & Eden, M. (1984) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198406000-00028 · Cited by 429 · see citing works
Cuadra, M. B., Cammoun, L., Butz, T., Cuisenaire, O., & Thiran, J. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.857652 · Cited by 365 · see citing works
Quantitative Analysis in Nuclear Medicine Imaging
Zaidi, H. (2006) · Springer eBooks · doi:10.1007/b107410 · Cited by 266 · see citing works
Self-citationComparative evaluation of MR-based partial-volume correction schemes for PET.
MELTZER, C. C., Kinahan, P. E., Greer, P. J., Nichols, T. E., Comtat, C., Cantwell, M. N., Lin, M., & Price, J. C. (1999) · PubMed · Cited by 254 · see citing works
Zaidi, H., Montandon, M., & Slosman, D. O. (2003) · Medical Physics · doi:10.1118/1.1569270 · Cited by 233 · see citing works
Self-citationQuarantelli, M., Berkouk, K., Prinster, A., Landeau, B., Svarer, C., Balkay, L., Alfano, B., Brunetti, A., Baron, J., & Salvatore, M. (2004) · PubMed · Cited by 224 · see citing works
Atlas-Based Segmentation of Pathological MR Brain Images Using a Model of Lesion Growth
BachCuadra, M., Pollo, C., Bardera, A., Cuisenaire, O., Villemure, J., & Thiran, J. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.834618 · Cited by 209 · see citing works
Positron Emission Tomography Partial Volume Correction: Estimation and Algorithms
Aston, J. A. D., Cunningham, V. J., Asselin, M., Hammers, A., Evans, A. C., & Gunn, R. N. (2002) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200208000-00014 · Cited by 178 · see citing works
A Robust Method for Extraction and Automatic Segmentation of Brain Images
Kovacevic, N., Lobaugh, N. J., Bronskill, M. J., Levine, B., Feinstein, A., & Black, S. E. (2002) · NeuroImage · doi:10.1006/nimg.2002.1221 · Cited by 155 · see citing works
Frouin, V., Comtat, C., Reilhac, A., & Grégoire, M. (2002) · PubMed · Cited by 148 · see citing works
Brain tissue classification of magnetic resonance images using partial volume modeling
Ruan, S., Jaggi, C., Xue, J., Fadili, J. M., & Bloyet, D. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.897810 · Cited by 147 · see citing works
MELTZER, C. C., Zubieta, J. K., Links, J. M., Brakeman, P., Stumpf, M. J., & Frost, J. J. (1996) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199607000-00016 · Cited by 143 · see citing works
Quantitative comparison of four brain extraction algorithms
Boesen, K., Rehm, K., Schaper, K. A., Stoltzner, S. E., Woods, R. P., Eileen Luders, A., & Rottenberg, D. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.03.010 · Cited by 127 · see citing works
Geometric strategies for neuroanatomic analysis from MRI
Duncan, J. S., Papademetris, X., Yang, J., Jackowski, M. P., Zeng, X., & Staib, L. H. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.027 · Cited by 119 · see citing works
Evaluation of anatomy based reconstruction for partial volume correction in brain FDG-PET
Baete, K., Nuyts, J. L., Laere, K. V., Paesschen, W. V., Ceyssens, S. K., Ceuninck, L. D., Gheysens, O. S., Kelles, A., den Eynden, J. V., Suetens, P., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.04.041 · Cited by 118 · see citing works
Physiological imaging of the brain with PET
GJEDDE, A. H. (2001) · Cited by 108 · see citing works
Lemieux, L., Hammers, A., Mackinnon, T., & Liu, R. S. N. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10436 · Cited by 79 · see citing works
Suri, J. S., Singh, S. K., & Reden, L. (2002) · Pattern Analysis and Applications · doi:10.1007/s100440200005 · Cited by 72 · see citing works
Validation of Partial Tissue Segmentation of Single-Channel Magnetic Resonance Images of the Brain
Grabowski, T. J., Frank, R. J., Szumski, N. R., Brown, C. K., & Damasio, H. (2000) · NeuroImage · doi:10.1006/nimg.2000.0649 · Cited by 67 · see citing works
Strul, D., & Bendriem, B. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199905000-00009 · Cited by 51 · see citing works
Archibald, R. K., Chen, K., Gelb, A., & Renaut, R. A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00260-x · Cited by 49 · see citing works
Registration, segmentation, and visualization of multimodal brain images
Viergever, M. A., Maintz, J. B. A., Niessen, W. J., Noordmans, H. J., Pluim, J. P. W., Stokking, R., & Vincken, K. L. (2001) · Computerized Medical Imaging and Graphics · doi:10.1016/s0895-6111(00)00065-3 · Cited by 46 · see citing works
Image Segmentation Techniques in Nuclear Medicine Imaging
Boudraa, A., & Zaidi, H. (2006) · Kluwer Academic Publishers eBooks · doi:10.1007/0-387-25444-7_10 · Cited by 38 · see citing works
Self-citationQuantitative Analysis in Nuclear Medicine Imaging
Ranade, V. (2006) · American Journal of Therapeutics · doi:10.1097/00045391-200607000-00018 · Cited by 28 · see citing works
The New Challenges of Brain PET Imaging Technology
Zaidi, H., & Montandon, M. (2006) · Current Medical Imaging Formerly Current Medical Imaging Reviews · doi:10.2174/157340506775541596 · Cited by 27 · see citing works
Self-citationZaidi, H., Sossi, V., & Hendee, W. R. (2004) · Medical Physics · doi:10.1118/1.1642653 · Cited by 25 · see citing works
Self-citationSegmentation of brain structures in presence of a space-occupying lesion
Pollo, C., Cuadra, M. B., Cuisenaire, O., Villemure, J., & Thiran, J. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.10.004 · Cited by 20 · see citing works
Voxel based analysis of tissue volume from MRI data
Thacker, N. A., Williamson, D. C., & Pokrić, M. (2004) · British Journal of Radiology · doi:10.1259/bjr/11445826 · Cited by 18 · see citing works
Flagged first, then by citations
3 of the 48 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
Automated medical image segmentation techniques
Sharma, N., & Aggarwal, L. (2010) · Journal of Medical Physics · doi:10.4103/0971-6203.58777 · Cited by 754 · see citing works
Erlandsson, K., Buvat, I., Pretorius, P. H., Thomas, B. A., & Hutton, B. F. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/21/r119 · Cited by 731 · see citing works
Episodic memory loss is related to hippocampal-mediated -amyloid deposition in elderly subjects
Mormino, E. C., Kluth, J. T., Madison, C. M., Rabinovici, G. D., Baker, S. L., Miller, B. L., Koeppe, R. A., Mathis, C. A., Weiner, M. W., Jagust, W. J., et al. (2009) · Brain · doi:10.1093/brain/awn320 · Cited by 684 · see citing works
Deep learning for tomographic image reconstruction
Wang, G., Ye, J. C., & Man, B. D. (2020) · Nature Machine Intelligence · doi:10.1038/s42256-020-00273-z · Cited by 560 · see citing works
An Open Source Multivariate Framework for n-Tissue Segmentation with Evaluation on Public Data
Avants, B., Tustison, N. J., Wu, J., Cook, P. A., & Gee, J. C. (2011) · Neuroinformatics · doi:10.1007/s12021-011-9109-y · Cited by 559 · see citing works
Highlights of 30 th Annual Conference of Association of Medical Physicists of India (AMPICON-2009)
Sd, S. (2010) · Journal of Medical Physics · doi:10.4103/0971-6203.58775 · Cited by 511 · see citing works
Voxel-based mapping of brain gray matter volume and glucose metabolism profiles in normal aging
Kalpouzos, G., Chételat, G., Baron, J.-C., Landeau, B., Mevel, K., Godeau, C., Barré, L., Constans, J.-M., Viader, F., Eustache, F., et al. (2009) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2007.05.019 · Cited by 392 · see citing works
Regional variability of imaging biomarkers in autosomal dominant Alzheimer's disease
Benzinger, T. L. S., Blazey, T., Jack, C. R., Koeppe, R. A., Su, Y., Xiong, C., Raichle, M. E., Snyder, A. Z., Ances, B. M., Bateman, R. J., et al. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1317918110 · Cited by 391 · see citing works
Zaidi, H., & Naqa, I. E. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1423-3 · Cited by 365 · see citing works
Self-citationCatana, C., van der Kouwe, A. J. W., Benner, T., Michel, C. J., Hamm, M., Fenchel, M., Fischl, B. R., Rosen, B. R., Schmand, M. J., & Sorensen, A. G. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.069112 · Cited by 355 · see citing works
MRBrainS Challenge: Online Evaluation Framework for Brain Image Segmentation in 3T MRI Scans
Mendrik, A. M., Vincken, K. L., Kuijf, H. J., Breeuwer, M., Bouvy, W. H., de Bresser, J., Alansary, A., de Bruijne, M., Carass, A., El-Baz, A., et al. (2015) · Computational Intelligence and Neuroscience · doi:10.1155/2015/813696 · Cited by 261 · see citing works
Partial volume correction in quantitative amyloid imaging
Su, Y., Blazey, T. M., Snyder, A. Z., Raichle, M. E., Marcus, D. S., Ances, B. M., Bateman, R. J., Cairns, N. J., Aldea, P., Cash, L., et al. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.11.058 · Cited by 247 · see citing works
Chen, X., Sachdev, P. S., Wen, W. X., & Anstey, K. J. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.03.063 · Cited by 236 · see citing works
Evaluation of automated brain MR image segmentation and volumetry methods
Klauschen, F., Goldman, A. L., Barra, V., Meyer‐Lindenberg, A., & Lundervold, A. (2008) · Human Brain Mapping · doi:10.1002/hbm.20599 · Cited by 217 · see citing works
An outlook on future design of hybrid PET/MRI systems
Zaidi, H., & Guerra, A. D. (2011) · Medical Physics · doi:10.1118/1.3633909 · Cited by 190 · see citing works
Self-citationPartial Volume Correction Strategies in PET
ROUSSET, O. G., Rahmim, A., Alavi, A. A., & Zaidi, H. (2007) · PET Clinics · doi:10.1016/j.cpet.2007.10.005 · Cited by 188 · see citing works
Self-citationTohka, J., & Reilhac, A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.10.038 · Cited by 150 · see citing works
Dewey, J. J., Hana, G., Russell, T., Price, J., McCaffrey, D., Harezlak, J., Sem, E., Anyanwu, J. C., Guttmann, C. R. G., NAVIA, B. A., et al. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.033 · Cited by 126 · see citing works
Can sulci protect the brain from traumatic injury?
Ho, J. S., & Kleiven, S. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.06.051 · Cited by 118 · see citing works
Acosta‐Cabronero, J., Williams, G. B., Pereira, J., Pengas, G., & Nestor, P. J. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.10.051 · Cited by 107 · see citing works
PET quantification: strategies for partial volume correction
Bettinardi, V., Castiglioni, I., De Bernardi, E., & Gilardi, M. C. (2014) · Clinical and Translational Imaging · doi:10.1007/s40336-014-0066-y · Cited by 105 · see citing works
ROUSSET, O. G., Collins, D. L., Rahmim, A., & Wong, D. F. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.048330 · Cited by 104 · see citing works
Basu, S. K., Zaidi, H., Houseni, M., Bural, G. G., Udupa, J., Acton, P. D., Torigian, D. A., & Alavi, A. A. (2007) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2007.01.005 · Cited by 103 · see citing works
Self-citationFunctional and structural synergy for resolution recovery and partial volume correction in brain PET
Shidahara, M., Tsoumpas, C., Hammers, A., Boussion, N., Visvikis, D., Suhara, T., Kanno, I., & Turkheimer, F. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.09.012 · Cited by 91 · see citing works
PET/MRI: a frontier in era of complementary hybrid imaging
Musafargani, S., Ghosh, K. K., Mishra, S., Mahalakshmi, P., Padmanabhan, P., & Gulyás, B. Z. (2018) · European Journal of Hybrid Imaging · doi:10.1186/s41824-018-0030-6 · Cited by 78 · see citing works
Mannheim, J. G., Schmid, A. M., Schwenck, J., Katiyar, P., Herfert, K., Pichler, B. J., & Disselhorst, J. A. (2018) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2018.02.011 · Cited by 70 · see citing works
The Clinical Role of Fusion Imaging Using PET, CT, and MR Imaging
Zaidi, H., Montandon, M., & Alavi, A. A. (2009) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2009.09.010 · Cited by 57 · see citing works
Self-citationCelle, S., Delon‐Martin, C., Roche, F., Barthélemy, J., Pépin, J., & Michel Dojat, D. (2015) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2015.03.001 · Cited by 56 · see citing works
An MR image-guided, voxel-based partial volume correction method for PET images
Wang, H., & Fei, B. (2011) · Medical Physics · doi:10.1118/1.3665704 · Cited by 48 · see citing works
MR Imaging–Guided Partial Volume Correction of PET Data in PET/MR Imaging
Erlandsson, K., Dickson, J. C., Arridge, S., Atkinson, D., Sebastien Ourselin, A., & Hutton, B. F. (2015) · PET Clinics · doi:10.1016/j.cpet.2015.09.002 · Cited by 45 · see citing works
Joint solution for PET image segmentation, denoising, and partial volume correction
Xu, Z., Gao, M., Papadakis, G. Z., Luna, B. M., Jain, S. K., Mollura, D. J., & Bağcı, U. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.03.007 · Cited by 44 · see citing works
Gutiérrez, D., Montandon, M., Assal, F., Allaoua, M., Ratib, O. M., Lövblad, K., & Zaidi, H. (2012) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2012.09.001 · Cited by 43 · see citing works
Self-citationBonte, S., Vandemaele, P., Verleden, S. E., Audenaert, K., Deblaere, K., Goethals, I., & Holen, R. V. (2016) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-016-3569-0 · Cited by 42 · see citing works
MRI-Driven PET Image Optimization for Neurological Applications
Zhu, Y., & Zhu, X. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00782 · Cited by 42 · see citing works
Castiglioni, I., Gallivanone, F., Soda, P., Avanzo, M., Stancanello, J., Aiello, M., Interlenghi, M., & Salvatore, M. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-04414-4 · Cited by 41 · see citing works
PVE Correction in PET-CT Whole-Body Oncological Studies From PVE-Affected Images
Gallivanone, F., Stefano, A., Grosso, E., Canevari, C., Gianolli, L., Messa, C., Gilardi, M. C., & Castiglioni, I. (2011) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2011.2108316 · Cited by 41 · see citing works
The Promise of Hybrid PET\/MRI: Technical advances and clinical applications
Zaidi, H., & Becker, M. (2016) · IEEE Signal Processing Magazine · doi:10.1109/msp.2015.2482225 · Cited by 33 · see citing works
Self-citationXu, R., Luo, L., & Ohy, J. (2012) · InTech eBooks · doi:10.5772/27596 · Cited by 31 · see citing works
Meechai, T., Tepmongkol, S., & Pluempitiwiriyawej, C. (2014) · British Journal of Radiology · doi:10.1259/bjr.20140119 · Cited by 31 · see citing works
Amyloid-β and Glucose Metabolism in Alzheimer's Disease
Furst, A. J., & Lal, R. (2011) · Journal of Alzheimer s Disease · doi:10.3233/jad-2011-0066 · Cited by 31 · see citing works
Moore, S. C., Southekal, S. S., Park, M., McQuaid, S. J., Kijewski, M. F., & Müller, S. P. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2169981 · Cited by 31 · see citing works
Correction for Partial Volume Effects in Emission Tomography
ROUSSET, O. G., & Zaidi, H. (2006) · Springer eBooks · doi:10.1007/0-387-25444-7_8 · Cited by 29 · see citing works
Self-citationSanaat, A., Shooli, H., Boehringer, A. S., Sadeghi, M., Shiri, I., Salimi, Y., Ginovart, N., Garibotto, V., Arabi, H., & Zaidi, H. (2023) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-023-06152-0 · Cited by 27 · see citing works
Self-citationLöffler, J., Hamp, C., Scheidhauer, E., Carlo, D. D., Solbach, C., Abaei, A., Li, H., Glatting, G., Beer, A. J., Rasche, V., et al. (2021) · Cancers · doi:10.3390/cancers13164007 · Cited by 26 · see citing works
Lee, J., Ha, S., Kim, R. E. Y., Lee, M., Kim, D., & Lim, H. K. (2022) · Diagnostics · doi:10.3390/diagnostics12030623 · Cited by 26 · see citing works
Yun, H. J., Kwak, K., Lee, J., & Initiative, A. D. N. (2015) · PLoS ONE · doi:10.1371/journal.pone.0129250 · Cited by 26 · see citing works
Ho, J. S., von Holst, H., & Kleiven, S. (2009) · International Journal of Crashworthiness · doi:10.1080/13588260902895708 · Cited by 26 · see citing works
Azimi, M.-S., Rahmim, A., Arabi, H., Sanaat, A., Zeraatkar, N., Bouchareb, Y., Liu, C., Alavi, A. A., King, M. A., Boellaard, R., et al. (2025) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-025-07612-5 · Cited by 25 · see citing works
Self-citationShidahara, M., Tsoumpas, C., McGinnity, C. J., Kato, T., Tamura, H., Hammers, A., Watabe, H., & Turkheimer, F. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/10/3107 · Cited by 23 · see citing works
The Clinical Role of Fusion Imaging Using PET, CT, and MR Imaging
Zaidi, H., Montandon, M., & Alavi, A. A. (2008) · PET Clinics · doi:10.1016/j.cpet.2009.03.002 · Cited by 22 · see citing works
Self-citationQuantitative organ time activity curve extraction from rodent PET images without anatomical prior
Maroy, R., Boisgard, R., Comtat, C., Jégo, B., Fontyn, Y., Jan, S., Dubois, A., Trébossen, R., & Tavitian, B. (2010) · Medical Physics · doi:10.1118/1.3327454 · Cited by 19 · see citing works
Measuring structural complexity in brain images
Young, K., & Schuff, N. W. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.10.043 · Cited by 18 · see citing works
Noise suppressed partial volume correction for cardiac SPECT/CT
Chan, C., Liu, H., Grobshtein, Y., Stacy, M. R., Sinusas, A. J., & Liu, C. (2016) · Medical Physics · doi:10.1118/1.4961391 · Cited by 17 · see citing works
A Monte Carlo study of deconvolution algorithms for partial volume correction in quantitative PET
Tohka, J., & Reilhac, A. (2006) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2006.353719 · Cited by 16 · see citing works
Review of Segmentation Methods for Brain Tissue with Magnetic Resonance Images
Agrawal, R., & Шарма, М. (2014) · International Journal of Computer Network and Information Security · doi:10.5815/ijcnis.2014.04.07 · Cited by 15 · see citing works
Southekal, S. S., McQuaid, S. J., Kijewski, M. F., & Moore, S. C. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/3/685 · Cited by 15 · see citing works
Post-reconstruction-based partial volume correction methods: A comprehensive review
Jomaa, H., Mabrouk, R., & Khlifa, N. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.05.029 · Cited by 14 · see citing works
Molecular neuroimaging with PET/MRI
Garibotto, V., Förster, S., Haller, S., Vargas, M. I., & Drzezga, A. E. (2013) · Clinical and Translational Imaging · doi:10.1007/s40336-013-0007-1 · Cited by 13 · see citing works
Matoug, S., Abdel-Dayem, A. R., Passi, K., Gross, W., & Alqarni, M. (2012) · Journal of Physics Conference Series · doi:10.1088/1742-6596/341/1/012019 · Cited by 10 · see citing works
Generation of Patient Specific Finite Element Head Models
Ho, J. S. (2008) · KTH Publication Database DiVA (KTH Royal Institute of Technology) · Cited by 10 · see citing works
Structure-Function–Based Quantitative Brain Image Analysis
Zaidi, H., Montandon, M., & Assal, F. (2010) · PET Clinics · doi:10.1016/j.cpet.2010.02.003 · Cited by 9 · see citing works
Self-citationKrempser, A. R., Ichinose, R. M., de Sá, A. M. F. L. M., de Oliveira, S. M. V., & Carneiro, M. P. (2013) · Annals of Nuclear Medicine · doi:10.1007/s12149-013-0773-x · Cited by 9 · see citing works
Puigdellívol‐Sánchez, A., Reina, M. Á., San‐Molina, J., Escobar, J. M., Castedo, J., & Prats‐Galino, A. (2014) · Journal of Neuroimaging · doi:10.1111/jon.12150 · Cited by 8 · see citing works
Skull-stripping with machine learning deformable organisms
Prasad, G., Joshi, A. A., Feng, A., Toga, A. W., Thompson, P. M., & Terzopoulos, D. (2014) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.07.023 · Cited by 8 · see citing works
Comment on: “FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging, version 1.0”
Saboury, B., Torigian, D. A., & Alavi, A. A. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1458-5 · Cited by 8 · see citing works
Reply to: FDG PET and PET/CT: EANM procedure guideline for tumour PET imaging
imaging”, O. B. O. T. A. O. T. G. “. P. A. P. E. P. G. F. T. P., Boellaard, R., O’Doherty, M. J., Chiti, A., & Krause, B. J. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1459-4 · Cited by 8 · see citing works
Clinical and Research Applications of Quantitative PET Imaging
Basu, S. K., Zaidi, H., & Alavi, A. A. (2007) · PET Clinics · doi:10.1016/j.cpet.2007.10.002 · Cited by 7 · see citing works
Self-citationAutomatic Brain Segmentation for PET/MR Dual-Modal Images Through a Cross-Fusion Mechanism
Tang, H., Huang, Z., Li, W., Wu, Y., Yuan, J., Yang, Y., Zhang, Y., Qin, J., Zheng, H., Liang, D., et al. (2024) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3516012 · Cited by 6 · see citing works
Novel Quantitative Techniques in Hybrid (PET-MR) Imaging of Brain Tumors
Senthamizhchelvan, S., & Zaidi, H. (2012) · PET Clinics · doi:10.1016/j.cpet.2012.09.007 · Cited by 6 · see citing works
Self-citationAtlas-Based Whole-Body PET-CT Segmentation Using a Passive Contour Distance
Gigengack, F., Ruthotto, L., Jiang, X., Jan Modersitzki, C., Burger, M., Hermann, S., & Schäfers, K. P. (2013) · Lecture notes in computer science · doi:10.1007/978-3-642-36620-8_9 · Cited by 6 · see citing works
Anatomical structure segmentation in MRI brain images
Lakshmi, G. G., & Suruliandi, A. (2011) · International Conference on Emerging Trends in Electrical and Computer Technology · doi:10.1109/icetect.2011.5760225 · Cited by 6 · see citing works
Parghane, R. V., & Basu, S. K. (2022) · PET Clinics · doi:10.1016/j.cpet.2022.03.006 · Cited by 6 · see citing works
Catana, C., Cherry, S. R., & Sorensen, A. G. (2008) · touchREVIEWS in Neurology · doi:10.17925/usn.2008.04.02.76 · Cited by 5 · see citing works
Fast and accurate pseudo multispectral technique for whole-brain MRI tissue classification
Fatnassi, C., & Zaidi, H. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab239e · Cited by 4 · see citing works
Self-citationPartial Volume Correction in PET Imaging
Erlandsson, K. (2016) · Springer eBooks · doi:10.1007/978-3-319-40070-9_15 · Cited by 4 · see citing works
Park, S. Y., Lee, I., Lim, I., Kim, B. I., Choi, C. W., Ko, I. O., Byun, B. H., & Ha, J. H. (2025) · Nuclear Medicine and Molecular Imaging · doi:10.1007/s13139-025-00911-7 · Cited by 3 · see citing works
Role of Novel Quantitative Imaging Techniques in Hematological Malignancies
Parghane, R. V., & Basu, S. K. (2024) · PET Clinics · doi:10.1016/j.cpet.2024.05.008 · Cited by 3 · see citing works
Modern Quantitative Techniques for PET/CT/MR Hybrid Imaging
Saboury, B., Moghbel, M. C., Basu, S. K., & Alavi, A. A. (2012) · InTech eBooks · doi:10.5772/33882 · Cited by 3 · see citing works
MRI-Guided Partial Volume Correction in Brain PET Imaging: Comparison of Five Algorithms
Boivin, G., Genoud, V., & Zaidi, H. (2014) · Archive ouverte UNIGE (University of Geneva) · Cited by 3 · see citing works
Self-citationSu, K., Chen, J. S., Lee, J.-S., Hu, C.-M., Chang, C., Chou, Y.-H., Liu, R.-S., & Chen, J. (2011) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2011.01.004 · Cited by 3 · see citing works
Rong, Y., Vernaleken, I., Winz, O., Goedicke, A., Mottaghy, F. M., & Kops, E. R. (2014) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2014.08.001 · Cited by 3 · see citing works
Knešaurek, K. (2015) · World Journal of Nuclear Medicine · doi:10.4103/1450-1147.163246 · Cited by 3 · see citing works
Semi-automatic active contour-based segmentation to remove eyes, meninges, and skull from MRI
Barbosa, J. M. D., Nunes, T. L. G. M., Nunes, T. L. G. M., Rodrigues, A. C., & Morya, E. (2020) · Research on Biomedical Engineering · doi:10.1007/s42600-020-00066-8 · Cited by 2 · see citing works
Fourier-wavelet restoration in PET/CT brain studies
Knešaurek, K. (2012) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2012.06.032 · Cited by 2 · see citing works
Jomaa, H., Mabrouk, R., & Khlifa, N. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.101954 · Cited by 2 · see citing works
Matoug, S. (2015) · Lu Zone Ul (Laurentian University) · Cited by 2 · see citing works
Active Mask Framework for Segmentation of Fluorescence Microscope Images
Srinivasa, G. (2012) · Cited by 2 · see citing works
MRI Tissue Segmentation Using a Variational Multilayer Approach
Chung, G., Dinov, I. D., Toga, A. W., & Vese, L. A. (2010) · Springer eBooks · doi:10.1007/978-1-4419-5874-7_2 · Cited by 1 · see citing works
Various segmentation techniques for medical images and the role of IoT
Miya, J., Raj, S., Ansari, M. A., Kumar, S., & Sachdeva, N. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-21870-5.00034-0 · Cited by 1 · see citing works
Yavuz, G., Kovan, B., Toklu, T., Çermik, T. F., & Öztürk, C. (2025) · BioMedical Engineering OnLine · doi:10.1186/s12938-025-01330-7 · Cited by 1 · see citing works
Imagerie multimodale TEP et IRM dans la prise en charge des démences
Jeune, F. L., & Ferré, J. (2015) · Médecine Nucléaire · doi:10.1016/j.mednuc.2015.03.192 · Cited by 1 · see citing works
Performance Evaluation of Tumor Detection Techniques
Sinduja, A., & Suruliandi, A. (2015) · International Journal on Computational Science & Applications · doi:10.5121/ijcsa.2015.5303 · Cited by 1 · see citing works
Voting-based active contour segmentation of fMRI images of the brain
Srinivasa, G., Oak, V. S., Garg, S. J., Fickus, M. C., & Kovačević, J. (2008) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.2008.4711951 · Cited by 1 · see citing works
EVALUATION OF MR-BRAIN-VOLUMETRY METHODS
Klauschen, F., Goldman, A. L., Meyer‐Lindenberg, A., Lunder Vold, A., & Barra, V. (2007) · HAL · Cited by 1 · see citing works
Analyse der recovery-korrigierten Standardized Uptake Values bei der Positronenemissionstomographie
Bielas, H. (2007) · Universitätsbibliothek der FU Berlin Hochschulschriftenstelle u. Dokumentenserver · doi:10.17169/refubium-17653
Matoug, S., & Abdel-Dayem, A. R. (2012) · Journal of Physics Conference Series · doi:10.1088/1742-6596/341/1/012020
Basu, S. K., Zaidi, H., & Alavi, A. A. (2007) · PET Clinics · doi:10.1016/j.cpet.2007.10.001
Self-citationSimultaneous PET and MR Imaging of the Human Brain
Catana, C., Sorensen, A. G., & Rosen, B. R. (2011) · Springer eBooks · doi:10.1007/978-1-4419-0345-7_42
종설 : 뇌기능 양전자방출단층촬영영상 분석 기법의 방법론적 고찰
박해정 (2007) · Nuclear Medicine and Molecular Imaging
Quantitation and Data Analysis in Hybrid PET/MRI Systems
Castiglioni, I., Gallivanone, F., & Gilardi, M. C. (2016) · Springer eBooks · doi:10.1007/978-3-319-31614-7_3
- Authors
- Zaidi, H., Ruest, T., Schoenahl, F., & Montandon, M.-L.
- Affiliations
- University Hospital of Geneva (CH)
- Corresponding author
- Zaidi, Habib
- ORCID
- Zaidi, Habib
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2006-10
- Volume
- 32
- Issue
- 4
- Pages
- 1591-1607
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2166728875
- Cited by
- 108
- References
- 48
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 3 · 2023: 2 · 2022: 3 · 2021: 1 · 2020: 3 · 2019: 3 · 2018: 4 · 2017: 1 · 2016: 6 · 2015: 8 · 2014: 8 · 2013: 6 · 2012: 12
- FWCI
- 9.85
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- NeuroImage (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (SNSF 3152A0-102143)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Keywords
- brain MRI segmentation, partial volume correction, PET, cerebrospinal fluid, expectation-maximization segmentation, histogram-based segmentation, 18F-FDG PET, 18F-DOPA PET, MRI phantom, statistical parametric mapping
- MeSH terms
- Algorithms, Brain, Brain Mapping, Data Interpretation, Statistical, Dihydroxyphenylalanine, Humans, Magnetic Resonance Imaging, Phantoms, Imaging, Radiopharmaceuticals, Fluorodeoxyglucose F18, Positron-Emission Tomography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review