The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Adaptive filtering to reduce global interference in non-invasive NIRS measures of brain activation: How well and when does it work?
Open accessAbstract
In previous work we introduced a novel method for reducing global interference, based on adaptive filtering, to improve the contrast to noise ratio (CNR) of evoked hemodynamic responses measured non-invasively with near infrared spectroscopy (NIRS). Here, we address the issue of how to generally apply the proposed adaptive filtering method. A total of 156 evoked visual response measurements, collected from 15 individuals, were analyzed. The similarity (correlation) between measurements with far and near source-detector separations collected during the rest period before visual stimulation was used as indicator of global interference dominance. A detailed analysis of CNR improvement in oxy-hemoglobin (O2Hb) and deoxy-hemoglobin (HHb), as a function of the rest period correlation coefficient, is presented. Results show that for O2Hb measurements, 66% exhibited substantial global interference. For this dataset, dominated by global interference, 71% of the measurements revealed CNR improvements after adaptive filtering, with a mean CNR improvement of 60%. No CNR improvement was observed for HHb. This study corroborates our previous finding that adaptive filtering provides an effective method to increase CNR when there is strong global interference, and also provides a practical way for determining when and where to apply this technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mixed-Effects Models in S and S-PLUS
(2001) · Technometrics · doi:10.1198/tech.2001.s574 · Cited by 9,278
Mixed-Effects Models in S and S-PLUS
(2000) · Statistics and Computing · doi:10.1007/b98882 · Cited by 930
Schroeter, M. L., Zysset, S., Kupka, T., Kruggel, F., & von Cramon, D. Y. (2002) · Human Brain Mapping · doi:10.1002/hbm.10052 · Cited by 259
Cited by
Scholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.004 · Cited by 2,002
fNIRS-based brain-computer interfaces: a review
Naseer, N., & Hong, K.-S. (2015) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2015.00003 · Cited by 988
Cui, X., Bray, S., & Reiss, A. L. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.11.050 · Cited by 807
Scholkmann, F., Spichtig, S., Muehlemann, T., & Wolf, M. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/5/004 · Cited by 683
Wavelet-based motion artifact removal for functional near-infrared spectroscopy
Molavi, B., & Dumont, G. A. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/2/259 · Cited by 623
Metadata
- Authors
- Zhang, Q., Strangman, G. E., & Ganis, G.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2009-04
- Volume
- 45
- Issue
- 3
- Pages
- 788-794
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2007884967
- Cited by
- 176
- References
- 3
- FWCI
- 7.52
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Adaptive filtering to reduce global interference in non-invasive NIRS measures of brain activation: How well and when does it work? https://app.cochat.ai/papers/10.1016/j.neuroimage.2008.12.048
- The paper
- Zhang, Q., Strangman, G. E., & Ganis, G. (2009). Adaptive filtering to reduce global interference in non-invasive NIRS measures of brain activation: How well and when does it work? NeuroImage. https://doi.org/10.1016/j.neuroimage.2008.12.048
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.