The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
How to detect and reduce movement artifacts in near-infrared imaging using moving standard deviation and spline interpolation
Open accessAbstract
Near-infrared imaging (NIRI) is a neuroimaging technique which enables us to non-invasively measure hemodynamic changes in the human brain. Since the technique is very sensitive, the movement of a subject can cause movement artifacts (MAs), which affect the signal quality and results to a high degree. No general method is yet available to reduce these MAs effectively. The aim was to develop a new MA reduction method. A method based on moving standard deviation and spline interpolation was developed. It enables the semi-automatic detection and reduction of MAs in the data. It was validated using simulated and real NIRI signals. The results show that a significant reduction of MAs and an increase in signal quality are achieved. The effectiveness and usability of the method is demonstrated by the improved detection of evoked hemodynamic responses. The present method can not only be used in the postprocessing of NIRI signals but also for other kinds of data containing artifacts, for example ECG or EEG signals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Comment on the modified Beer–Lambert law for scattering media
Sassaroli, A., & Fantini, S. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/14/n07 · Cited by 352
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Cited by
Herold, F., Wiegel, P., Scholkmann, F., & Müller, N. (2018) · Journal of Clinical Medicine · doi:10.3390/jcm7120466 · Cited by 482
Self-citationCooper, R. J., Selb, J., Gagnon, L., Phillip, D., Schytz, H. W., Iversen, H. K., Ashina, M., & Boas, D. A. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00147 · Cited by 421
Reindl, V., Gerloff, C., Scharke, W., & Konrad, K. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.05.060 · Cited by 411
Autoregressive model based algorithm for correcting motion and serially correlated errors in fNIRS
Barker, J. W., Aarabi, A., & Huppert, T. J. (2013) · Biomedical Optics Express · doi:10.1364/boe.4.001366 · Cited by 337
A Review on the Use of Wearable Functional Near‐Infrared Spectroscopy in Naturalistic Environments
Pinti, P., Aichelburg, C., Gilbert, S., Hamilton, A., Hirsch, J., Burgess, P., & Tachtsidis, I. (2018) · Japanese Psychological Research · doi:10.1111/jpr.12206 · Cited by 325
Metadata
- Authors
- Scholkmann, F., Spichtig, S., Muehlemann, T., & Wolf, M.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2010-03-22
- Volume
- 31
- Issue
- 5
- Pages
- 649-662
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W1996776986
- Cited by
- 683
- References
- 2
- FWCI
- 9.40
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: How to detect and reduce movement artifacts in near-infrared imaging using moving standard deviation and spline interpolation. https://app.cochat.ai/papers/10.1088/0967-3334/31/5/004
- The paper
- Scholkmann, F., Spichtig, S., Muehlemann, T., & Wolf, M. (2010). How to detect and reduce movement artifacts in near-infrared imaging using moving standard deviation and spline interpolation. Physiological Measurement. https://doi.org/10.1088/0967-3334/31/5/004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.