CoChat

Comparison of phantom and registration scaling corrections using the ADNI cohort

Open access
Clarkson, Matthew J., Ourselin, Sébastien, Nielsen, Casper, Leung, Kelvin K., Barnes, Josephine, Whitwell, Jennifer L., Gunter, Jeffrey L., Hill, Derek L.G., Weiner, Michael W., Jack, Clifford R., Fox, Nick C. · 2009 · NeuroImage
Cited by 54

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Rates of brain atrophy derived from serial magnetic resonance (MR) studies may be used to assess therapies for Alzheimer's disease (AD). These measures may be confounded by changes in scanner voxel sizes. For this reason, the Alzheimer's Disease Neuroimaging Initiative (ADNI) included the imaging of a geometric phantom with every scan. This study compares voxel scaling correction using a phantom with correction using a 9 degrees of freedom (9DOF) registration algorithm. We took 129 pairs of baseline and 1-year repeat scans, and calculated the volume scaling correction, previously measured using the phantom. We used the registration algorithm to quantify any residual scaling errors, and found the algorithm to be unbiased, with no significant (p = 0.97) difference between control (n = 79) and AD subjects (n = 50), but with a mean (SD) absolute volume change of 0.20 (0.20) % due to linear scalings. 9DOF registration was shown to be comparable to geometric phantom correction in terms of the effect on atrophy measurement and unbiased with respect to disease status. These results suggest that the additional expense and logistic effort of scanning a phantom with every patient scan can be avoided by registration-based scaling correction. Furthermore, based upon the atrophy rates in the AD subjects in this study, sample size requirements would be approximately 10–12% lower with (either) correction for voxel scaling than if no correction was used.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.neuroimage.2009.05.045

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 54

Metadata

Authors
Clarkson, M. J., Ourselin, S., Nielsen, C., Leung, K. K., Barnes, J., Whitwell, J. L., Gunter, J. L., Hill, D. L. G., Weiner, M. W., Jack, C. R., & Fox, N. C.
Venue
NeuroImage
Publisher
Elsevier BV
Published
2009-10
Volume
47
Issue
4
Pages
1506-1513
ISSN
1053-8119 (ISSN-L)
OpenAlex
W1968358515
Cited by
54
References
8
FWCI
5.35
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of phantom and registration scaling corrections using the ADNI cohort. https://app.cochat.ai/papers/10.1016/j.neuroimage.2009.05.045
The paper
Clarkson, M. J., Ourselin, S., Nielsen, C., Leung, K. K., Barnes, J., Whitwell, J. L., Gunter, J. L., Hill, D. L. G., Weiner, M. W., Jack, C. R., & Fox, N. C. (2009). Comparison of phantom and registration scaling corrections using the ADNI cohort. NeuroImage. https://doi.org/10.1016/j.neuroimage.2009.05.045

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.