Rapid semi-automatic segmentation of the spinal cord from magnetic resonance images: Application in multiple sclerosis
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
A new semi-automatic method for segmenting the spinal cord from MR images is presented. The method is based on an active surface (AS) model of the cord surface, with intrinsic smoothness constraints. The model is initialized by the user marking the approximate cord center-line on a few representative slices, and the compact surface parametrization results in a rapid segmentation, taking on the order of one minute. Using 3-D acquired T1-weighted images of the cervical spine from human controls and patients with multiple sclerosis, the intra- and inter-observer reproducibilities were evaluated, and compared favorably with an existing cord segmentation method. While the AS method overestimated the cord area by approximately 14% compared to manual outlining, correlations between cord cross-sectional area and clinical disability scores confirmed the relevance of the new method in measuring cord atrophy in multiple sclerosis. Segmentation of the cord from 2-D multi-slice T2-weighted images is also demonstrated over the cervical and thoracic region. Since the cord center-line is an intrinsic parameter extracted as part of the segmentation process, the image can be resampled such that the center-line forms one coordinate axis of a new image, allowing simple visualization of the cord structure and pathology; this could find wider application in standard radiological practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kass, M., Witkin, A., & Terzopoulos, D. (1988) · International Journal of Computer Vision · doi:10.1007/bf00133570 · Cited by 17,070
Rating neurologic impairment in multiple sclerosis: An expanded disability status scale (EDSS)
Kurtzke, J. F. (1983) · Neurology · doi:10.1212/wnl.33.11.1444 · Cited by 15,011
(1973) · CERN Document Server (European Organization for Nuclear Research) · Cited by 12,895
Differential geometry of curves and surfaces
(2011) · Choice Reviews Online · doi:10.5860/choice.48-3330 · Cited by 3,706
Defining the clinical course of multiple sclerosis: Results of an international survey
Lublin, F. D., Reingold, S. C., & National Multiple Sclerosis Society (USA) Advisory Committee on Clinical Trials of New Agents in Multiple Sclerosis* (1996) · Neurology · doi:10.1212/wnl.46.4.907 · Cited by 3,686
Measurement of signal intensities in the presence of noise in MR images
Henkelman, R. M. (1985) · Medical Physics · doi:10.1118/1.595711 · Cited by 1,017
Pattern Classification and Scene Analysis.
Grenander, U., Duda, R. O., & Hart, P. E. (1974) · Journal of the American Statistical Association · doi:10.2307/2286028 · Cited by 1,006
Differential Geometry of Curves and Surfaces
Banchoff, T., & Lovett, S. (2016) · Chapman & Hall/CRC eBooks · doi:10.1201/b18913 · Cited by 836
Hauser, S. L., Dawson, D. M., Lehrich, J. R., Beal, M. F., Kevy, S. V., Propper, R. D., Mills, J. A., & Weiner, H. L. (1983) · New England Journal of Medicine · doi:10.1056/nejm198301273080401 · Cited by 827
Losseff, N. A., Webb, S. L., O'Riordan, J. I., Page, R., Wang, L., Barker, G. J., Tofts, P. S., McDonald, W. I., Miller, D. H., & Thompson, A. J. (1996) · Brain · doi:10.1093/brain/119.3.701 · Cited by 643
Cited by
SCT: Spinal Cord Toolbox, an open-source software for processing spinal cord MRI data
De Leener, B., Lévy, S., Dupont, S. M., Fonov, V. S., Stikov, N., Louis Collins, D., Callot, V., & Cohen-Adad, J. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.10.009 · Cited by 621
Gros, C., De Leener, B., Badji, A., Maranzano, J., Eden, D., Dupont, S. M., Talbott, J., Zhuoquiong, R., Liu, Y., Granberg, T., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.09.081 · Cited by 289
Self-citationFreund, P., Weiskopf, N., Ashburner, J., Wolf, K., Sutter, R., Altmann, D. R., Friston, K., Thompson, A., & Curt, A. (2013) · The Lancet Neurology · doi:10.1016/s1474-4422(13)70146-7 · Cited by 271
Spinal cord MRI in multiple sclerosis—diagnostic, prognostic and clinical value
Kearney, H., Miller, D. H., & Ciccarelli, O. (2015) · Nature Reviews Neurology · doi:10.1038/nrneurol.2015.80 · Cited by 235
The current state-of-the-art of spinal cord imaging: Applications
Wheeler-Kingshott, C. A., Stroman, P. W., Schwab, J. M., Bacon, M., Bosma, R., Brooks, J., Cadotte, D. W., Carlstedt, T., Ciccarelli, O., Cohen-Adad, J., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.07.014 · Cited by 201
“…of a novel development that could rapidly be adopted, recently, a new semi-automatic method based on an active surface (AS) model of the cord surface allowing segmentation of long portions of the cord (Horsfield et al., 2010) has shown to provide reproducible measures of cord CSA from C2 to C5.”
InfluentialSelf-citationSpinal cord gray matter atrophy correlates with multiple sclerosis disability
Schlaeger, R., Papinutto, N., Panara, V., Bevan, C., Lobach, I. V., Bucci, M., Caverzasi, E., Gelfand, J. M., Green, A. J., Jordan, K. M., et al. (2014) · Annals of Neurology · doi:10.1002/ana.24241 · Cited by 196
“The UCCA measurement was semiautomated.(27) The GM area was manually segmented 33 by each reader, and the mean GM area was calculated per reader.”
MethodNeurite orientation dispersion and density imaging of the healthy cervical spinal cord in vivo
Grussu, F., Schneider, T., Zhang, H., Alexander, D. C., & Wheeler–Kingshott, C. A. M. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.01.045 · Cited by 118
“A semiautomatic active surface method (Horsfield et al., 2010) implemented in Jim (http://www.xinapse.com/home.php) was employed to obtain the cord outline (“cord finder” tool) and to create a binary mask (fitting cord mask) of the whole cord.”
BackgroundMethodRegev, K., Healy, B. C., Khalid, F., Paul, A., Chu, R., Tauhid, S., Tummala, S., Diaz-Cruz, C., Raheja, R., Mazzola, M. A., et al. (2017) · JAMA Neurology · doi:10.1001/jamaneurol.2016.5197 · Cited by 68
Self-citationCollorone, S., Cawley, N., Grussu, F., Prados, F., Tona, F., Calvi, A., Kanber, B., Schneider, T., Kipp, L., Zhang, H., et al. (2020) · Multiple Sclerosis Journal · doi:10.1177/1352458519885107 · Cited by 64
Metadata
- Authors
- Horsfield, M. A., Sala, S., Neema, M., Absinta, M., Bakshi, A., Sormani, M. P., Rocca, M. A., Bakshi, R., & Filippi, M.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2010-04
- Volume
- 50
- Issue
- 2
- Pages
- 446-455
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2045782417
- Cited by
- 257
- References
- 25
- FWCI
- 16.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.