Regional reproducibility of pulsed arterial spin labeling perfusion imaging at 3T
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Arterial spin labeling (ASL) is a promising non-invasive magnetic resonance imaging (MRI) technique for measuring regional cerebral blood flow (rCBF) or perfusion in vivo. To evaluate the feasibility of ASL as a biomarker for clinical trials, it is important to examine test-retest reproducibility. We investigated both inter- and intra-session reproducibility of perfusion MRI using a pulsed ASL (PASL) sequence PICORE Q2TIPS with an echo-planar imaging (EPI) readout. Structural MRI regions of interest (ROIs) were extracted individually by automated parcellation and segmentation methods using FreeSurfer. These cortical and subcortical ROIs were used to assess regional perfusion stability. Our results indicated regional variability in grey matter rCBF. Although rCBF measurements were characterized by intersubject variation, our results also indicated relatively less within-subject variability estimated as within-subject standard deviation (SDW) (intersession SDW: 2.0 to 8.8; intrasession SDW: 2.8 to 9.6) and acceptable reliabilities as measured using intraclass correlation coefficient (ICC) (intersession ICC: 0.68 to 0.94; intrasession ICC: 0.66 to 0.95) for regional MRI perfusion measurements using the PICORE Q2TIPS technique. Overall, our findings suggest that PASL is a technique with good within and between session reproducibility. Further reproducibility studies in target populations relevant for specific clinical trials of neurovascular related agents will be important and the present results provide a framework for such assessments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Fox, M. D., Snyder, A. Z., Zacks, J. M., & Raichle, M. E. (2006) · Nature Neuroscience · doi:10.1038/nn1616 · Cited by 660
Arterial spin labeling perfusion fMRI with very low task frequency
Wang, J., Aguirre, G. K., Kimberg, D. Y., Roc, A. C., Li, L., & Detre, J. A. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10437 · Cited by 316 · cited 1×
“…images to produce a perfusion weighted time series, and then quantitative rCBF map for each PASL scan, was generated using one compartment model (Wang et al., 2003b): Where ΔM is the mean difference in the signal intensity between label and control images, λ is the blood/tissue water partition…”
Physiological noise reduction for arterial spin labeling functional MRI
Restom, K., Behzadi, Y., & Liu, T. T. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.026 · Cited by 101 · cited 1×
“Like other dynamic MRI scans, the ASL signal can be modulated by physiological noise (Restom et al., 2006).”
Cited by
A neuroradiologist’s guide to arterial spin labeling MRI in clinical practice
Grade, M., Hernandez Tamames, J. A., Pizzini, F. B., Achten, E., Golay, X., & Smits, M. (2015) · Neuroradiology · doi:10.1007/s00234-015-1571-z · Cited by 298
Kullmann, S., Heni, M., Veit, R., Scheffler, K., Machann, J., Häring, H.-U., Fritsche, A., & Preissl, H. (2015) · Diabetes Care · doi:10.2337/dc14-2319 · Cited by 175
“offset–corrected inversion pulse and echo planar imaging readout for acquisition (16).”
BackgroundMachine learning‐based multimodal prediction of language outcomes in chronic aphasia
Kristinsson, S., Zhang, W., Rorden, C., Newman‐Norlund, R., Basilakos, A., Bonilha, L., Yourganov, G., Xiao, F., Hillis, A., & Fridriksson, J. (2021) · Human Brain Mapping · doi:10.1002/hbm.25321 · Cited by 64
Brain insulin responsiveness is linked to age and peripheral insulin sensitivity
Wagner, L., Veit, R., Kübler, C., Fritsche, A., Häring, H., Birkenfeld, A. L., Heni, M., Preissl, H., & Kullmann, S. (2023) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.15094 · Cited by 22
Metadata
- Authors
- Wang, Y., Saykin, A. J., Pfeuffer, J., Lin, C., Mosier, K. M., Shen, L., Kim, S., & Hutchins, G. D.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2011-01
- Volume
- 54
- Issue
- 2
- Pages
- 1188-1195
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2066165241
- Cited by
- 91
- References
- 4
- FWCI
- 7.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Regional reproducibility of pulsed arterial spin labeling perfusion imaging at 3T. https://app.cochat.ai/papers/10.1016/j.neuroimage.2010.08.043
- The paper
- Wang, Y., Saykin, A. J., Pfeuffer, J., Lin, C., Mosier, K. M., Shen, L., Kim, S., & Hutchins, G. D. (2011). Regional reproducibility of pulsed arterial spin labeling perfusion imaging at 3T. NeuroImage. https://doi.org/10.1016/j.neuroimage.2010.08.043
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.