CoChat

Direct visualization of short transverse relaxation time component (ViSTa)

Open access
Oh, Se-Hong, Bilello, Michel, Schindler, Matthew, Markowitz, Clyde E., Detre, John A., Lee, Jongho · 2013 · NeuroImage
Cited by 89

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

White matter of the brain has been demonstrated to have multiple relaxation components. Among them, the short transverse relaxation time component (T2 < 40 ms; T2* < 25 ms at 3T) has been suggested to originate from myelin water whereas long transverse relaxation time components have been associated with axonal and/or interstitial water. In myelin water imaging, T2 or T2* signal decay is measured to estimate myelin water fraction based on T2 or T2* differences among the water components. This method has been demonstrated to be sensitive to demyelination in the brain but suffers from low SNR and image artifacts originating from ill-conditioned multi-exponential fitting. In this study, a novel approach that selectively acquires short transverse relaxation time signal is proposed. The method utilizes a double inversion RF pair to suppress a range of long T1 signal. This suppression leaves short T2* signal, which has been suggested to have short T1, as the primary source of the image. The experimental results confirms that after suppression of long T1 signals, the image is dominated by short T2* in the range of myelin water, allowing us to directly visualize the short transverse relaxation time component in the brain. Compared to conventional myelin water imaging, this new method of direct visualization of short relaxation time component (ViSTa) provides high quality images. When applied to multiple sclerosis patients, chronic lesions show significantly reduced signal intensity in ViSTa images suggesting sensitivity to demyelination.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.neuroimage.2013.06.047

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • MR diffusion tensor spectroscopy and imaging

    Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970 · cited 1×

    “Several MRI methods including myelin water imaging (Mackay et al., 1994), magnetization transfer imaging (Balaban and Ceckler, 1992; Gass et al., 1994), and diffusion tensor imaging (Basser et al., 1994; Werring et al., 1999) have been proposed as potential biomarkers for myelin.”
    Method
  • T1, T2 relaxation and magnetization transfer in tissue at 3T

    Stanisz, G. J., Odrobina, E. E., Pun, J., Escaravage, M., Graham, S. J., Bronskill, M. J., & Henkelman, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20605 · Cited by 1,266 · cited 3×

    “…be explained by a multiple water component model in white matter that includes a short T1 and T2⁎ component and long T1 and T2⁎ component(s) (Deoni et al., 2008; Does and Gore, 2002; Helms and Hagberg, 2009; Koenig et al., 1990; Labadie et al., 2013; Lancaster et al., 2002; Stanisz et al., 2005).”
    Background
  • Diffusion tensor imaging of lesions and normal-appearing white matter in multiple sclerosis

    Werring, D. J., Clark, C. A., Barker, G. J., Thompson, A. J., & Miller, D. H. (1999) · Neurology · doi:10.1212/wnl.52.8.1626 · Cited by 621 · cited 2×

    “Several MRI methods including myelin water imaging (Mackay et al., 1994), magnetization transfer imaging (Balaban and Ceckler, 1992; Gass et al., 1994), and diffusion tensor imaging (Basser et al., 1994; Werring et al., 1999) have been proposed as potential biomarkers for myelin.”
    BackgroundMethod
  • Magnetic Resonance Imaging of Myelin

    Laule, C., Vavasour, I. M., Kolind, S. H., Li, D. K. B., Traboulsee, T. L., Moore, G. R. W., & MacKay, A. L. (2007) · Neurotherapeutics · doi:10.1016/j.nurt.2007.05.004 · Cited by 334

  • MR properties of excised neural tissue following experimentally induced inflammation

    Stanisz, G. J., Webb, S., Munro, C. A., Pun, T., & Midha, R. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20008 · Cited by 138 · cited 6×

    “Four patients were scanned on a clinical 3 TMRI scanner (Trio, Siemens) thatwas different from the scanner used for the healthy volunteers.”
    BackgroundInfluential

Show all 5 references

Cited by

Metadata

Authors
Oh, S.-H., Bilello, M., Schindler, M., Markowitz, C. E., Detre, J. A., & Lee, J.
Venue
NeuroImage
Publisher
Elsevier BV
Published
2013-12
Volume
83
Pages
485-492
ISSN
1053-8119 (ISSN-L)
OpenAlex
W1992778295
Cited by
89
References
5
FWCI
4.04
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.