Rapid, high-resolution quantitative magnetization transfer MRI of the human spinal cord
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Quantitative magnetization transfer (qMT) imaging can provide indices describing the interactions between free water protons and immobile macromolecular protons. These indices include the macromolecular proton fraction (MPF), which has been shown to correlate with myelin content in white matter. Because of the long scan times required for high-resolution spinal cord imaging, qMT studies of the human spinal cord have not found wide-spread application. Herein, we investigated whether these limitations could be overcome by utilizing only a single MT-weighted acquisition and a reference measurement, as was recently proposed in the brain. High-resolution, in vivo qMT data were obtained at 3.0 tesla in the spinal cords of healthy volunteers and patients with relapsing remitting multiple sclerosis (MS). Low- and high-resolution acquisitions (low/high resolution = 1×1×5 mm3/0.65×0.65×5 mm3) with clinically acceptable scan times (12 min/7 min) were evaluated. We also evaluated the reliability over time and the sensitivity of the model to the assumptions made in the single-point method, both in disease and healthy tissue. Our findings suggest that the single point qMT technique can provide maps of the MPF in the spinal cord in vivo with excellent grey/white matter contrast, can be reliably obtained within reasonable scan times, and are sensitive to MS pathology. Consistent with previous qMT studies in the brain, the observed MPF values were higher in healthy white matter (0.16±0.01) than in grey matter (0.13±0.01) and in MS lesions (0.09±0.01). The single point qMT technique applied at high resolution provides an improved method for obtaining qMT in the human spinal cord and may offer a reliable outcome measure for evaluating spinal cord disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
T1, T2 relaxation and magnetization transfer in tissue at 3T
Stanisz, G. J., Odrobina, E. E., Pun, J., Escaravage, M., Graham, S. J., Bronskill, M. J., & Henkelman, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20605 · Cited by 1,266 · cited 5×
“One challenge facing theMTR andMTCSF is that they are sequence and scanner dependent (Berry et al., 1999;Henkelmanet al., 1993; Stanisz et al., 2005) and, therefore, cannot readily be used to quantitatively study tissue changes in the spinal cord across sites.”
BackgroundInfluentialSmith, S. A., Golay, X., Fatemi, A., Mahmood, A., Raymond, G. V., Moser, H. W., van Zijl, P. C. M., & Stanisz, G. J. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21827 · Cited by 53 · cited 4×
“…the relationship between neurological function and spinal cord microstructure (Cohen-Adad et al., 2011; Ellingson et al., 2008; Filippi and Agosta, 2010; Freund et al., 2010; Nair et al., 2010; Naismith et al., 2013; Oh et al., 2013; Poloni et al., 2011; Smith et al., 2009; Zackowski et al., 2009).”
BackgroundSelf-citation
Cited by
Neurite dispersion: a new marker of multiple sclerosis spinal cord pathology?
Grussu, F., Schneider, T., Tur, C., Yates, R. L., Tachrount, M., Ianuş, A., Yiannakas, M. C., Newcombe, J., Zhang, H., Alexander, D. C., et al. (2017) · Annals of Clinical and Translational Neurology · doi:10.1002/acn3.445 · Cited by 312
Microstructural imaging in the spinal cord and validation strategies
Cohen-Adad, J. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.04.009 · Cited by 50
Cervical spinal cord susceptibility-weighted MRI at 7T: application to multiple sclerosis
Clarke, M. A., Witt, A. A., Robison, R. K., Fleishman, S., Combes, A. J. E., Houston, D., Prock, L. E., Sweeney, G., O'Grady, K. P., McKnight, C. D., et al. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120460 · Cited by 21
“To more fully understand the tissue changes observed herein and expand clinical translation capabilities, it is also important to improve shimming, evaluate respiration and/or cardiac triggering, and explore the presence of gadolinium enhancement in these lesions (Smith et al., 2014).”
Self-citation
Metadata
- Authors
- Smith, A. K., Dortch, R. D., Dethrage, L. M., & Smith, S. A.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2014-07
- Volume
- 95
- Pages
- 106-116
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W1984134121
- Cited by
- 54
- References
- 3
- FWCI
- 4.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.