Systematic comparison between a wireless EEG system with dry electrodes and a wired EEG system with wet electrodes
Open accessAbstract
&NA; Recent advances in dry electrodes technology have facilitated the recording of EEG in situations not previously possible, thanks to the relatively swift electrode preparation and avoidance of applying gel to subject's hair. However, to become a true alternative, these systems should be compared to state‐of‐the‐art wet EEG systems commonly used in clinical or research applications. In our study, we conducted a systematic comparison of electrodes application speed, subject comfort, and most critically electrophysiological signal quality between the conventional and wired Biosemi EEG system using wet active electrodes and the compact and wireless F1 EEG system consisting of dry passive electrodes. All subjects (n = 27) participated in two recording sessions on separate days, one with the wet EEG system and one with the dry EEG system, in which the session order was counterbalanced across subjects. In each session, we recorded their EEG during separate rest periods with eyes open and closed followed by two versions of a serial visual presentation target detection task. Each task component allows for a neural measure reflecting different characteristics of the data, including spectral power in canonical low frequency bands, event‐related potential components (specifically, the P3b), and single trial classification based on machine learning. The performance across the two systems was similar in most measures, including the P3b amplitude and topography, as well as low frequency (theta, alpha, and beta) spectral power at rest. Both EEG systems performed well above chance in the classification analysis, with a marginal advantage of the wet system over the dry. Critically, all aforementioned electrophysiological metrics showed significant positive correlations (r = 0.54–0.89) between the two EEG systems. This multitude of measures provides a comprehensive comparison that captures different aspects of EEG data, including temporal precision, frequency domain as well as multivariate patterns of activity. Taken together, our results indicate that the dry EEG system used in this experiment can effectively record electrophysiological measures commonly used across the research and clinical contexts with comparable quality to the conventional wet EEG system. HighlightsEEG signal quality was compared within subjects between wet and dry EEG systems.Compared metrics included P3b, resting state EEG, and single trial classification.Performance across the two systems was similar in most measures.These measures showed positive correlations between the two systems.Dry electrodes can record EEG measures with comparable quality to wet electrodes.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Wireless EEG performance for sleep monitoring has been compared with conventional EEG that is part of PSG and has demonstrated strong results.
“Their performance for sleep monitoring has been compared with conventional EEG that is part of PSG and has demonstrated strong results57,58.”
From The future of sleep health: a data-driven revolution in sleep science and medicine (2020) · cites this paper as [57]
The Introduction (page unavailable) describes a comparison of wireless dry EEG with conventional wired wet EEG, and the Discussion (page unavailable) reports comparable signal quality. But the recordings were made during waking rest and visual tasks; the paper does not report a comparison for sleep monitoring or against EEG used in PSG. (LLM, conf=0.88)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371 · see citing works
Oostenveld, R., Fries, P., Maris, E., & Schoffelen, J.-M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/156869 · Cited by 10,323 · see citing works
Updating P300: An integrative theory of P3a and P3b
Polich, J. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.04.019 · Cited by 7,919 · see citing works
Spherical splines for scalp potential and current density mapping
Perrin, F., Pernier, J., Bertrand, O., & Echallier, J. F. (1989) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(89)90180-6 · Cited by 2,706 · see citing works
A wandering mind is an unhappy mind
Killingsworth, M. A., & Gilbert, D. T. (2010) · Science · doi:10.1126/science.1192439 · Cited by 2,575 · see citing works
Smallwood, J., & Schooler, J. W. (2006) · Psychological Bulletin · doi:10.1037/0033-2909.132.6.946 · Cited by 2,067 · see citing works
On the utility of P3 amplitude as a measure of processing capacity
Kok, A. (2001) · Psychophysiology · doi:10.1017/s0048577201990559 · Cited by 1,766 · see citing works
A spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577 · see citing works
(2002) · Cited by 1,481 · see citing works
Inspired by Distraction: Mind Wandering Facilitates Creative Incubation
Baird, B., Smallwood, J., Mrazek, M. D., Kam, J. W. Y., Franklin, M. S., & Schooler, J. W. (2012) · Psychological Science · doi:10.1177/0956797612446024 · Cited by 975 · see citing works
Self-citationThe P300: Where in the Brain Is It Produced and What Does It Tell Us?
Linden, D. E. J. (2005) · The Neuroscientist · doi:10.1177/1073858405280524 · Cited by 833 · see citing works
Depression, anxiety, and resting frontal EEG asymmetry: A meta-analytic review.
Thibodeau, R., Jorgensen, R. S., & Kim, S. (2006) · Journal of Abnormal Psychology · doi:10.1037/0021-843x.115.4.715 · Cited by 620 · see citing works
Neurophysiological Endophenotypes of Schizophrenia: The Viability of Selected Candidate Measures
Turetsky, B. I., Calkins, M. E., Light, G. A., D, A. O. M., Radant, A. D., & Swerdlow, N. R. (2006) · Schizophrenia Bulletin · doi:10.1093/schbul/sbl060 · Cited by 563 · see citing works
How about taking a low‐cost, small, and wireless EEG for a walk?
Debener, S., Minow, F., Emkes, R., Gandras, K., & Vos, M. D. (2012) · Psychophysiology · doi:10.1111/j.1469-8986.2012.01471.x · Cited by 543 · see citing works
Lost in thoughts: Neural markers of low alertness during mind wandering
Braboszcz, C., & Delorme, A. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.008 · Cited by 425 · see citing works
López-Gordo, M. A., Morillo, D., & Valle, F. (2014) · Sensors · doi:10.3390/s140712847 · Cited by 408 · see citing works
Unobtrusive ambulatory EEG using a smartphone and flexible printed electrodes around the ear
Debener, S., Emkes, R., Vos, M. D., & Bleichner, M. G. (2015) · Scientific Reports · doi:10.1038/srep16743 · Cited by 383 · see citing works
Novel Dry Polymer Foam Electrodes for Long-Term EEG Measurement
Lin, C., Liao, L., Liu, Y., Wang, I.-J., Lin, B., & Chang, J.-Y. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2102353 · Cited by 336 · see citing works
The utility of neurophysiological markers in the study of alcoholism
Bernice Porjesz, A., Rangaswamy, M., Kamarajan, C., Jones, K. A., Padmanabhapillai, A., & Begleiter, H. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.12.016 · Cited by 330 · see citing works
Liao, L., Chen, C., Wang, I.-J., et al. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-5 · Cited by 259 · see citing works
Towards a truly mobile auditory brain–computer interface: Exploring the P300 to take away
Vos, M. D., Gandras, K., & Debener, S. (2013) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2013.08.010 · Cited by 205 · see citing works
Comparison of Dry and Gel Based Electrodes for P300 Brain–Computer Interfaces
Guger, C., Krausz, G., Allison, B. Z., & Edlinger, G. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00060 · Cited by 190 · see citing works
A dry electrode for EEG recording
Taheri, B. A., Knight, R. T., & Smith, R. L. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90053-1 · Cited by 177 · see citing works
Self-citationBabiloni, C., Carducci, F., Lizio, R., Vecchio, F., Baglieri, A., Bernardini, S., Cavedo, E., Bozzao, A., Buttinelli, C., Esposito, F., et al. (2012) · Human Brain Mapping · doi:10.1002/hbm.22005 · Cited by 175 · see citing works
A cell-phone-based brain–computer interface for communication in daily life
Wang, Y.-T., Wang, Y., & Jung, T. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025018 · Cited by 174 · see citing works
Noninvasive Neural Prostheses Using Mobile and Wireless EEG
Lin, C., Ko, L., Chiou, J., Duann, J., Huang, R., Liang, S., Chiu, T.-W., & Jung, T. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922561 · Cited by 160 · see citing works
P300, Probability, and Interstimulus Interval
Polich, J. M. (1990) · Psychophysiology · doi:10.1111/j.1469-8986.1990.tb02333.x · Cited by 149 · see citing works
P300 speller BCI with a mobile EEG system: comparison to a traditional amplifier
Vos, M. D., Kroesen, M., Emkes, R., et al. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/036008 · Cited by 141 · see citing works
Novel Multipin Electrode Cap System for Dry Electroencephalography
Fiedler, P., Pedrosa, P., Griebel, S., Fonseca, C., Vaz, F., Supriyanto, E., Zanow, F., & Haueisen, J. (2015) · Brain Topography · doi:10.1007/s10548-015-0435-5 · Cited by 127 · see citing works
Proposing Metrics for Benchmarking Novel EEG Technologies Towards Real-World Measurements
Oliveira, A. S., Schlink, B. R., Hairston, W. D., Peter König, B., & Ferris, D. P. (2016) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2016.00188 · Cited by 108 · see citing works
Kam, J. W. Y., & Handy, T. C. (2013) · Frontiers in Psychology · doi:10.3389/fpsyg.2013.00725 · Cited by 105 · see citing works
Self-citationFuhrmann Alpert, G., Manor, R., Spanier, A. B., Deouell, L. Y., & Geva, A. B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2289898 · Cited by 74 · see citing works
Self-citationAutopilot, Mind Wandering, and the Out of the Loop Performance Problem
Gouraud, J., Arnaud Delorme, A., & Berberian, B. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00541 · Cited by 59 · see citing works
Towards ambulatory brain-computer interfaces
Lotte, F., Fujisawa, J., Touyama, H., Ito, R., Hirose, M., & Lécuyer, A. (2009) · International Conference on Advances in Computer Entertainment Technology (ACE) · doi:10.1145/1690388.1690452 · Cited by 56 · see citing works
A Non-Adhesive Solid-Gel Electrode for a Non-Invasive Brain–Machine Interface
Toyama, S., Takano, K., & Kansaku, K. (2012) · Frontiers in Neurology · doi:10.3389/fneur.2012.00114 · Cited by 46 · see citing works
Käthner, I., Halder, S., Hintermüller, C., Espinosa, A., Guger, C., Miralles, F., Vargiu, E., Dauwalder, S., Rafael-Palou, X., Solà, M., et al. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00286 · Cited by 46 · see citing works
An active, microfabricated, scalp electrode array for EEG recording
Alizadeh-Taheri, B., Smith, R. L., & Knight, R. T. (1996) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(97)80023-4 · Cited by 36 · see citing works
Self-citationA Wearable Channel Selection-Based Brain-Computer Interface for Motor Imagery Detection
Lo, C.-C., Chien, T.-Y., Chen, Y., Tsai, S.-H. L., Fang, W.-C., & Lin, B. (2016) · Sensors · doi:10.3390/s16020213 · Cited by 35 · see citing works
Yu, Y.-H., Lu, S.-W., Liao, L., & Lin, C. (2014) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2014.2367518 · Cited by 27 · see citing works
myBrain: a novel EEG embedded system for epilepsy monitoring
Pinho, F., Cerqueira, J., Correia, J. H., Sousa, N., & Dias, N. S. (2017) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2017.1382585 · Cited by 26 · see citing works
Burton, A. (2015) · The Lancet Neurology · doi:10.1016/s1474-4422(15)00311-7 · Cited by 3 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
The future of sleep health: a data-driven revolution in sleep science and medicine
Perez-Pozuelo, I., Zhai, B., Palotti, J., Mall, R., Aupetit, M., Garcia-Gomez, J. M., Taheri, S., Guan, Y., & Fernandez-Luque, L. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0244-4 · Cited by 311 · see citing works
Dementia ConnEEGtome: towards multicentric harmonization of EEG connectivity in neurodegeneration
Prado, P., Birba, A., Cruzat, J., Santamaría-García, H., Parra, M., Moguilner, S., Tagliazucchi, E., & Ibáñez, A. (2022) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2021.12.008 · Cited by 43 · see citing works
- Authors
- Kam, J. W. Y., Griffin, S., Shen, A., Patel, S., Hinrichs, H., Heinze, H.-J., Deouell, L. Y., & Knight, R. T.
- Affiliations
- University of California, Berkeley (US)
- Otto-von-Guericke-Universität Magdeburg (DE)
- Hebrew University of Jerusalem (IL)
- Corresponding author
- Kam, Julia W.Y.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2019-01
- Volume
- 184
- Pages
- 119-129
- ISSN
- 1053-8119 (ISSN-L)
- PMC
- PMC6568010
- OpenAlex
- W2890088122
- Semantic Scholar
- 19db683d05643f4b3c78c698a8dc09ccb146eabb
- Cited by
- 188
- References
- 41
- Citations by year
- 2026: 15 · 2025: 29 · 2024: 20 · 2023: 25 · 2022: 24 · 2021: 36 · 2020: 22 · 2019: 16 · 2018: 1
- FWCI
- 11.17
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- NeuroImage (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Funders
- Israel Ministry of Defense
- McDonnell Foundation (R37NS21135)
- Jack H. Skirball Research Fund in Neuroscience
- Autonomie im Alter by the State of Saxony-Anhalt and the European Union (EFRE)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Emotion and Mood Recognition
- Keywords
- dry electrodes, wireless EEG, wet electrodes, EEG signal quality, P3b, event-related potentials, spectral power, single-trial classification, passive electrodes
- MeSH terms
- Adult, Brain, Electrodes, Electroencephalography, Female, Humans, Male, ROC Curve, Signal Processing, Computer-Assisted, Reproducibility of Results, Artifacts, Young Adult, Brain Waves, Wireless Technology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review