The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Ion Channel Voltage Sensors: Structure, Function, and Pathophysiology
Open accessAbstract
Voltage-gated ion channels generate electrical signals in species from bacteria to man. Their voltage-sensing modules are responsible for initiation of action potentials and graded membrane potential changes in response to synaptic input and other physiological stimuli. Extensive structure-function studies, structure determination, and molecular modeling are now converging on a sliding-helix mechanism for electromechanical coupling in which outward movement of gating charges in the S4 transmembrane segments catalyzed by sequential formation of ion pairs pulls the S4-S5 linker, bends the S6 segment, and opens the pore. Impairment of voltage-sensor function by mutations in Na+ channels contributes to several ion channelopathies, and gating pore current conducted by mutant voltage sensors in NaV1.4 channels is the primary pathophysiological mechanism in Hypokalemic Periodic Paralysis. The emerging structural model for voltage sensor function opens the way to development of a new generation of ionchannel drugs that act on voltage sensors rather than blocking the pore.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Phospholipids and the origin of cationic gating charges in voltage sensors
Schmidt, D., Jiang, Q.-X., & MacKinnon, R. (2006) · Nature · doi:10.1038/nature05416 · Cited by 417
The primary periodic paralyses: diagnosis, pathogenesis and treatment
Venance, S. L., Cannon, S. C., Fialho, D., Fontaine, B., Hanna, M. G., Ptacek, L. J., Tristani-Firouzi, M., Tawil, R., & Griggs, R. C. (2006) · Brain · doi:10.1093/brain/awh639 · Cited by 370
Cited by
The crystal structure of a voltage-gated sodium channel
Payandeh, J., Scheuer, T., Zheng, N., & Catterall, W. A. (2011) · Nature · doi:10.1038/nature10238 · Cited by 1,429
Self-citationVoltage‐gated sodium channels at 60: structure, function and pathophysiology
Catterall, W. A. (2012) · The Journal of Physiology · doi:10.1113/jphysiol.2011.224204 · Cited by 719
Self-citationNeuronal Voltage-Gated Calcium Channels: Structure, Function, and Dysfunction
Simms, B. A., & Zamponi, G. W. (2014) · Neuron · doi:10.1016/j.neuron.2014.03.016 · Cited by 675
Voltage-gated sodium channels: structure, function, pharmacology, and clinical indications
de Lera Ruiz, M., & Kraus, R. L. (2015) · Journal of Medicinal Chemistry · doi:10.1021/jm501981g · Cited by 548
Small-Conductance Ca2+-Activated K+Channels: Form and Function
Adelman, J. P., Maylie, J., & Sah, P. (2012) · Annual Review of Physiology · doi:10.1146/annurev-physiol-020911-153336 · Cited by 455
Metadata
- Authors
- Catterall, W. A.
- Venue
- Neuron
- Publisher
- Elsevier BV
- Published
- 2010-09
- Volume
- 67
- Issue
- 6
- Pages
- 915-928
- ISSN
- 0896-6273 (ISSN-L)
- OpenAlex
- W2045493336
- Cited by
- 568
- References
- 2
- FWCI
- 13.82
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ion Channel Voltage Sensors: Structure, Function, and Pathophysiology. https://app.cochat.ai/papers/10.1016/j.neuron.2010.08.021
- The paper
- Catterall, W. A. (2010). Ion Channel Voltage Sensors: Structure, Function, and Pathophysiology. Neuron. https://doi.org/10.1016/j.neuron.2010.08.021
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.