The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Statistical normalization techniques for magnetic resonance imaging
Open accessAbstract
While computed tomography and other imaging techniques are measured in absolute units with physical meaning, magnetic resonance images are expressed in arbitrary units that are difficult to interpret and differ between study visits and subjects. Much work in the image processing literature on intensity normalization has focused on histogram matching and other histogram mapping techniques, with little emphasis on normalizing images to have biologically interpretable units. Furthermore, there are no formalized principles or goals for the crucial comparability of image intensities within and across subjects. To address this, we propose a set of criteria necessary for the normalization of images. We further propose simple and robust biologically motivated normalization techniques for multisequence brain imaging that have the same interpretation across acquisitions and satisfy the proposed criteria. We compare the performance of different normalization methods in thousands of images of patients with Alzheimer's disease, hundreds of patients with multiple sclerosis, and hundreds of healthy subjects obtained in several different studies at dozens of imaging centers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Exploration, normalization, and summaries of high density oligonucleotide array probe level data
Irizarry, R. A. (2003) · Biostatistics · doi:10.1093/biostatistics/4.2.249 · Cited by 10,603
Fast robust automated brain extraction
Smith, S. M. (2002) · Human Brain Mapping · doi:10.1002/hbm.10062 · Cited by 10,496
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731 · cited 1×
“All images were corrected for spatial inhomogeneity (Sled et al., 1998) and rigidly aligned across modalities at each study visit to the Montreal Neurological Institute template.”
MethodThe Alzheimer’s disease neuroimaging initiative (ADNI): MRI methods
Jack, C. R., Bernstein, M. A., Fox, N. C., Thompson, P., Alexander, G., Harvey, D., Borowski, B., Britson, P. J., L. Whitwell, J., Ward, C., et al. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21049 · Cited by 4,347
A Class of Statistics with Asymptotically Normal Distribution
Hoeffding, W. (1948) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177730196 · Cited by 1,928
A Class of Statistics with Asymptotically Normal Distribution
Hoeffding, W. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-0919-5_20 · Cited by 1,851
Ellis, K. A., Bush, A. I., Darby, D., De Fazio, D., Foster, J., Hudson, P., Lautenschlager, N. T., Lenzo, N., Martins, R. N., Maruff, P., et al. (2009) · International Psychogeriatrics · doi:10.1017/s1041610209009405 · Cited by 968
New variants of a method of MRI scale standardization
Nyul, L. G., Udupa, J. K., & Zhang, X. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.836373 · Cited by 956
On standardizing the MR image intensity scale
Ny�l, L. G., & Udupa, J. K. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199912)42:6<1072::aid-mrm11>3.0.co;2-m · Cited by 583
Ryan, T. P. (2004) · Journal of Quality Technology · doi:10.1080/00224065.2004.11980270 · Cited by 581
A topology-preserving approach to the segmentation of brain images with multiple sclerosis lesions
Shiee, N., Bazin, P.-L., Ozturk, A., Reich, D. S., Calabresi, P. A., & Pham, D. L. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.09.005 · Cited by 331
Self-citationSemiparametric regression during 2003–2007
Ruppert, D., Wand, M. P., & Carroll, R. J. (2009) · Electronic Journal of Statistics · doi:10.1214/09-ejs525 · Cited by 250
Evaluating intensity normalization on MRIs of human brain with multiple sclerosis
Shah, M., Xiao, Y., Subbanna, N., Francis, S., Arnold, D. L., Collins, D. L., & Arbel, T. (2011) · Medical Image Analysis · doi:10.1016/j.media.2010.12.003 · Cited by 178
Leung, K. K., Clarkson, M. J., Bartlett, J. W., Clegg, S., Jack, C. R., Weiner, M. W., Fox, N. C., & Ourselin, S. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.12.059 · Cited by 158
New methods of MR image intensity standardization via generalized scale
Madabhushi, A., & Udupa, J. K. (2006) · Medical Physics · doi:10.1118/1.2335487 · Cited by 138
The Java Image Science Toolkit (JIST) for Rapid Prototyping and Publishing of Neuroimaging Software
Lucas, B. C., Bogovic, J., Carass, A., Bazin, P., Prince, J. L., Pham, D. L., & Landman, B. A. (2010) · Neuroinformatics · doi:10.1007/s12021-009-9061-2 · Cited by 133
Self-citationTopology-Preserving Tissue Classification of Magnetic Resonance Brain Images
Bazin, P., & Pham, D. L. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.893283 · Cited by 129
Self-citationLoizou, C. P., Murray, V., Pattichis, M. S., Seimenis, I., Pantziaris, M., & Pattichis, C. S. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2091279 · Cited by 112
Time-series analysis of MRI intensity patterns in multiple sclerosis
Meier, D., & Guttmann, C. R. G. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00354-9 · Cited by 104
Vision, modeling and visualization 2004
Herholz, S., Chuang, L. L., Tanner, T. G., Bülthoff, H. H., & Fleming, W. (2004) · Computers & Graphics · doi:10.1016/s0097-8493(04)00100-1 · Cited by 104
Sweeney, E. M., Shinohara, R. T., Shiee, N., Mateen, F. J., Chudgar, A. A., Cuzzocreo, J. L., Calabresi, P. A., Pham, D. L., Reich, D. S., & Crainiceanu, C. M. (2013) · NeuroImage Clinical · doi:10.1016/j.nicl.2013.03.002 · Cited by 103
Self-citationGray matter atrophy rate as a marker of disease progression in AD
Anderson, V. M., Schott, J. M., Bartlett, J. W., Leung, K. K., Miller, D. H., & Fox, N. C. (2010) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2010.11.001 · Cited by 87
Normalization of joint image-intensity statistics in MRI using the kullback-leibler divergence
Weisenfeld, N., & Warfield, S. K. (2005) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2004.1398484 · Cited by 66
Brain MR image normalization in texture analysis of multiple sclerosis
Loizou, C. P., Pantziaris, M., Seimenis, I., & Pattichis, C. S. (2009) · IEEE International Conference on Information Technology and Applications in Biomedicine · doi:10.1109/itab.2009.5394331 · Cited by 61
Consistent intensity correction of MR images
Pierre Hellier, J. (2004) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.2003.1247161 · Cited by 42
Shinohara, R. T., Crainiceanu, C. M., Caffo, B. S., Gaitán, M. I., & Reich, D. S. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.05.038 · Cited by 42
Self-citation
Cited by
Harmonization of cortical thickness measurements across scanners and sites
Fortin, J.-P., Cullen, N., Sheline, Y. I., Taylor, W. D., Aselcioglu, I., Cook, P. A., Adams, P., Cooper, C., Fava, M., McGrath, P. J., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.11.024 · Cited by 1,580
“For instance, for WhiteStripe and RAVEL, control features in the WM and in the CSF are required, which do not make sense in the context of cortical thickness measurements in the GM.”
MethodSelf-citationHarmonization of multi-site diffusion tensor imaging data
Fortin, J.-P., Parker, D., Tunç, B., Watanabe, T., Elliott, M. A., Ruparel, K., Roalf, D. R., Satterthwaite, T. D., Gur, R. C., Gur, R. E., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.08.047 · Cited by 1,261
“It is an extension of a previous intensity normalization, called White Stripe [Shinohara et al., 2014], developed to normalize white matter intensities in structural MRI.”
MethodSelf-citationLiu, Z., Wang, S., Dong, D., Wei, J., Fang, C., Zhou, X., Sun, K., Li, L., Li, B., Wang, M., et al. (2019) · Theranostics · doi:10.7150/thno.30309 · Cited by 967
Kickingereder, P., Burth, S., Wick, A., Götz, M., Eidel, O., Schlemmer, H.-P., Maier-Hein, K. H., Wick, W., Bendszus, M., Radbruch, A., et al. (2016) · Radiology · doi:10.1148/radiol.2016160845 · Cited by 446
Persistent 7-tesla phase rim predicts poor outcome in new multiple sclerosis patient lesions
Absinta, M., Sati, P., Schindler, M., Leibovitch, E. C., Ohayon, J., Wu, T., Meani, A., Filippi, M., Jacobson, S., Cortese, I. C. M., et al. (2016) · Journal of Clinical Investigation · doi:10.1172/jci86198 · Cited by 327
“ized using WhiteStripe (52), whereby intensity values are expressed in”
MethodSelf-citation
Metadata
- Authors
- Shinohara, R. T., Sweeney, E. M., Goldsmith, J., Shiee, N., Mateen, F. J., Calabresi, P. A., Jarso, S., Pham, D. L., Reich, D. S., & Crainiceanu, C. M.
- Venue
- NeuroImage: Clinical
- Publisher
- Elsevier BV
- Published
- 2014
- Volume
- 6
- Pages
- 9-19
- ISSN
- 2213-1582 (ISSN-L)
- OpenAlex
- W2166219471
- Cited by
- 425
- References
- 26
- FWCI
- 7.94
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.