Statistical normalization techniques for magnetic resonance imaging
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
While computed tomography and other imaging techniques are measured in absolute units with physical meaning, magnetic resonance images are expressed in arbitrary units that are difficult to interpret and differ between study visits and subjects. Much work in the image processing literature on intensity normalization has focused on histogram matching and other histogram mapping techniques, with little emphasis on normalizing images to have biologically interpretable units. Furthermore, there are no formalized principles or goals for the crucial comparability of image intensities within and across subjects. To address this, we propose a set of criteria necessary for the normalization of images. We further propose simple and robust biologically motivated normalization techniques for multisequence brain imaging that have the same interpretation across acquisitions and satisfy the proposed criteria. We compare the performance of different normalization methods in thousands of images of patients with Alzheimer's disease, hundreds of patients with multiple sclerosis, and hundreds of healthy subjects obtained in several different studies at dozens of imaging centers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Exploration, normalization, and summaries of high density oligonucleotide array probe level data
Irizarry, R. A. (2003) · Biostatistics · doi:10.1093/biostatistics/4.2.249 · Cited by 10,603
Fast robust automated brain extraction
Smith, S. M. (2002) · Human Brain Mapping · doi:10.1002/hbm.10062 · Cited by 10,496
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731 · cited 1×
“All images were corrected for spatial inhomogeneity (Sled et al., 1998) and rigidly aligned across modalities at each study visit to the Montreal Neurological Institute template.”
MethodThe Alzheimer’s disease neuroimaging initiative (ADNI): MRI methods
Jack, C. R., Bernstein, M. A., Fox, N. C., Thompson, P., Alexander, G., Harvey, D., Borowski, B., Britson, P. J., L. Whitwell, J., Ward, C., et al. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21049 · Cited by 4,347
A Class of Statistics with Asymptotically Normal Distribution
Hoeffding, W. (1948) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177730196 · Cited by 1,928
A Class of Statistics with Asymptotically Normal Distribution
Hoeffding, W. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-0919-5_20 · Cited by 1,851
Ellis, K. A., Bush, A. I., Darby, D., De Fazio, D., Foster, J., Hudson, P., Lautenschlager, N. T., Lenzo, N., Martins, R. N., Maruff, P., et al. (2009) · International Psychogeriatrics · doi:10.1017/s1041610209009405 · Cited by 968
New variants of a method of MRI scale standardization
Nyul, L. G., Udupa, J. K., & Zhang, X. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.836373 · Cited by 956
On standardizing the MR image intensity scale
Ny�l, L. G., & Udupa, J. K. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199912)42:6<1072::aid-mrm11>3.0.co;2-m · Cited by 583
Ryan, T. P. (2004) · Journal of Quality Technology · doi:10.1080/00224065.2004.11980270 · Cited by 581
Cited by
Harmonization of cortical thickness measurements across scanners and sites
Fortin, J.-P., Cullen, N., Sheline, Y. I., Taylor, W. D., Aselcioglu, I., Cook, P. A., Adams, P., Cooper, C., Fava, M., McGrath, P. J., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.11.024 · Cited by 1,580
“For instance, for WhiteStripe and RAVEL, control features in the WM and in the CSF are required, which do not make sense in the context of cortical thickness measurements in the GM.”
MethodSelf-citationHarmonization of multi-site diffusion tensor imaging data
Fortin, J.-P., Parker, D., Tunç, B., Watanabe, T., Elliott, M. A., Ruparel, K., Roalf, D. R., Satterthwaite, T. D., Gur, R. C., Gur, R. E., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.08.047 · Cited by 1,261
“It is an extension of a previous intensity normalization, called White Stripe [Shinohara et al., 2014], developed to normalize white matter intensities in structural MRI.”
MethodSelf-citationLiu, Z., Wang, S., Dong, D., Wei, J., Fang, C., Zhou, X., Sun, K., Li, L., Li, B., Wang, M., et al. (2019) · Theranostics · doi:10.7150/thno.30309 · Cited by 967
Kickingereder, P., Burth, S., Wick, A., Götz, M., Eidel, O., Schlemmer, H.-P., Maier-Hein, K. H., Wick, W., Bendszus, M., Radbruch, A., et al. (2016) · Radiology · doi:10.1148/radiol.2016160845 · Cited by 446
Persistent 7-tesla phase rim predicts poor outcome in new multiple sclerosis patient lesions
Absinta, M., Sati, P., Schindler, M., Leibovitch, E. C., Ohayon, J., Wu, T., Meani, A., Filippi, M., Jacobson, S., Cortese, I. C. M., et al. (2016) · Journal of Clinical Investigation · doi:10.1172/jci86198 · Cited by 327
“ized using WhiteStripe (52), whereby intensity values are expressed in”
MethodSelf-citationMS-Net: Multi-Site Network for Improving Prostate Segmentation With Heterogeneous MRI Data
Liu, Q., Dou, Q., Yu, L., & Heng, P. A. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.2974574 · Cited by 308
MRI‐only based synthetic CT generation using dense cycle consistent generative adversarial networks
Lei, Y., Harms, J., Wang, T., Liu, Y., Shu, H., Jani, A. B., Curran, W. J., Mao, H., Liu, T., & Yang, X. (2019) · Medical Physics · doi:10.1002/mp.13617 · Cited by 297
Carré, A., Klausner, G., Edjlali, M., Lerousseau, M., Briend-Diop, J., Sun, R., Ammari, S., Reuzé, S., Alvarez Andres, E., Estienne, T., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-69298-z · Cited by 278
Kickingereder, P., Götz, M., Muschelli, J., Wick, A., Neuberger, U., Shinohara, R. T., Sill, M., Nowosielski, M., Schlemmer, H.-P., Radbruch, A., et al. (2016) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-16-0702 · Cited by 267
Self-citationRepeatability of Multiparametric Prostate MRI Radiomics Features
Schwier, M., van Griethuysen, J., Vangel, M. G., Pieper, S., Peled, S., Tempany, C., Aerts, H. J. W. L., Kikinis, R., Fennessy, F. M., & Fedorov, A. (2019) · Scientific Reports · doi:10.1038/s41598-019-45766-z · Cited by 237
Radiomics of Brain MRI: Utility in Prediction of Metastatic Tumor Type
Kniep, H. C., Madesta, F., Schneider, T., Hanning, U., Schönfeld, M. H., Schön, G., Fiehler, J., Gauer, T., Werner, R., & Gellissen, S. (2019) · Radiology · doi:10.1148/radiol.2018180946 · Cited by 237
Kickingereder, P., Neuberger, U., Bonekamp, D., Piechotta, P. L., Götz, M., Wick, A., Sill, M., Kratz, A., Shinohara, R. T., Jones, D. T. W., et al. (2018) · Neuro-Oncology · doi:10.1093/neuonc/nox188 · Cited by 219
Self-citationDavatzikos, C., Rathore, S., Bakas, S., Pati, S., Bergman, M., Kalarot, R., Sridharan, P., Gastounioti, A., Jahani, N., Cohen, E., et al. (2018) · Journal of Medical Imaging · doi:10.1117/1.jmi.5.1.011018 · Cited by 204
“Toward this end, CaPTk provides the WhiteStripe approach 28 (Appendix A, Table 7), which normalizes conventional MRI by detecting a latent subdistribution of normal tissue and linearly scaling the histogram of images.”
MethodSelf-citationEvaluating the impact of intensity normalization on MR image synthesis
Reinhold, J. C., Dewey, B. E., Carass, A., & Prince, J. L. (2019) · Medical Imaging 2019: Image Processing · doi:10.1117/12.2513089 · Cited by 206
Quantitative Phase Imaging and Artificial Intelligence: A Review
Jo, Y., Cho, H., Lee, S. Y., Choi, G., Kim, G., Min, H.-S., & Park, Y. (2019) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2018.2859234 · Cited by 192
Detect and correct bias in multi-site neuroimaging datasets
Wachinger, C., Rieckmann, A., & Pölsterl, S. (2021) · Medical Image Analysis · doi:10.1016/j.media.2020.101879 · Cited by 115
The Cancer Imaging Phenomics Toolkit (CaPTk): Technical Overview
Pati, S., Singh, A., Rathore, S., Gastounioti, A., Bergman, M., Ngo, P., Ha, S. M., Bounias, D., Minock, J., Murphy, G., et al. (2020) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-46643-5_38 · Cited by 94
Self-citationEffects of MRI scanner manufacturers in classification tasks with deep learning models
Kushol, R., Parnianpour, P., Wilman, A. H., Kalra, S., & Yang, Y.-H. (2023) · Scientific Reports · doi:10.1038/s41598-023-43715-5 · Cited by 54
“Lastly, we apply WhiteStripe intensity normalization using the Python intensity-normalization package 30 .”
Wang, C., Li, Y., Tsuboshita, Y., Sakurai, T., Goto, T., Yamaguchi, H., Yamashita, Y., Sekiguchi, A., Tachimori, H., Initiative, F. T. A. D. N., et al. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00577-x · Cited by 51
Distance-based analysis of variance for brain connectivity
Shinohara, R. T., Shou, H., Carone, M., Schultz, R., Tunc, B., Parker, D., Martin, M. L., & Verma, R. (2020) · Biometrics · doi:10.1111/biom.13123 · Cited by 6
Self-citation
Metadata
- Authors
- Shinohara, R. T., Sweeney, E. M., Goldsmith, J., Shiee, N., Mateen, F. J., Calabresi, P. A., Jarso, S., Pham, D. L., Reich, D. S., & Crainiceanu, C. M.
- Venue
- NeuroImage: Clinical
- Publisher
- Elsevier BV
- Published
- 2014
- Volume
- 6
- Pages
- 9-19
- ISSN
- 2213-1582 (ISSN-L)
- OpenAlex
- W2166219471
- Cited by
- 425
- References
- 26
- FWCI
- 7.94
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.