The DOI matches its Crossref record; 53 of the 56 references it cites were found in a registry or an index.
Concurrent in situ ion irradiation transmission electron microscope
Open accessAbstract
An in situ ion irradiation transmission electron microscope has been developed and is operational at Sandia National Laboratories. This facility permits high spatial resolution, real time observation of electron transparent samples under ion irradiation, implantation, mechanical loading, corrosive environments, and combinations thereof. This includes the simultaneous implantation of low-energy gas ions (0.8–30 keV) during high-energy heavy ion irradiation (0.8–48 MeV). Initial results in polycrystalline gold foils are provided to demonstrate the range of capabilities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“And amongst techniques such as in situ TEM [9] or in situ Raman spectroscopy [10] that can provide local structural information during irradiation, TGS is unique in its ability to continuously monitor thermal and elastic properties.”
From A facility for thermo-mechanical characterization of fusion magnet materials during cryogenic ion irradiation (2025) · cites this paper as [9]
The cited source says what the claim attributes to it.
In the citing paper
“And amongst techniques such as in situ TEM [9] or in situ Raman spectroscopy [10] that can provide local structural information during irradiation, TGS is unique in its ability to continuously monitor thermal and elastic properties.”
From A facility for thermo-mechanical characterization of fusion magnet materials during cryogenic ion irradiation (2025) · cites this paper as [9]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SRIM – The stopping and range of ions in matter (2010)
Ziegler, J. F., Ziegler, M. D., & Biersack, J. P. (2010) · Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2010.02.091 · Cited by 11,412
The Stopping and Ranges of Ions in Matter
(1980) · Elsevier eBooks · doi:10.1016/c2013-0-02882-4 · Cited by 3,012
Electron tomography and holography in materials science
Midgley, P. A., & Dunin‐Borkowski, R. E. (2009) · Nature Materials · doi:10.1038/nmat2406 · Cited by 884
Some thoughts on the mechanisms of in-reactor corrosion of zirconium alloys
Cox, B. (2005) · Journal of Nuclear Materials · doi:10.1016/j.jnucmat.2004.09.029 · Cited by 569
Radiation-induced segregation in binary and ternary alloys
Okamoto, P. R., & Rehn, L. E. (1979) · Journal of Nuclear Materials · doi:10.1016/0022-3115(79)90587-7 · Cited by 409
Observation of the One-Dimensional Diffusion of Nanometer-Sized Dislocation Loops
Arakawa, K., Ono, K., Isshiki, M., Mimura, K., Uchikoshi, M., & Mori, H. (2007) · Science · doi:10.1126/science.1145386 · Cited by 362
Kinetics of dislocations in pure Fe. Part I. In situ straining experiments at room temperature
Caillard, D. (2010) · Acta Materialia · doi:10.1016/j.actamat.2010.02.023 · Cited by 275
In-situ TEM tensile testing of DC magnetron sputtered and pulsed laser deposited Ni thin films
Hugo, R. C., Kung, H., Weertman, J., Mitra, R., Knapp, J. A., & Follstaedt, D. M. (2003) · Acta Materialia · doi:10.1016/s1359-6454(02)00599-2 · Cited by 217
Schwank, J. R., Shaneyfelt, M. R., & Dodd, P. E. (2013) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2013.2254722 · Cited by 206
The development of the electron microscope and of electron microscopy
Ruska, E. (1987) · Reviews of Modern Physics · doi:10.1103/revmodphys.59.627 · Cited by 176
Flagged first, then by citations
3 of the 56 references couldn’t be matched to a known paper.
Research works printed but not linked: 1
- Integrated Computational Materials Engineering: A Transformational Discipline for Improved Competitiveness and National Security, The National Academies Press, 2008.
Cited by
Sorted by citations
Items 101–128 of 128
Temperature Control in Liquid Cells for TEM
Dillon, S. J., & Chen, X. (2016) · Cambridge University Press eBooks · doi:10.1017/9781316337455.007 · Cited by 2
Cowen, B. J., El‐Genk, M. S., Hattar, K., & Briggs, S. A. (2018) · Journal of Applied Physics · doi:10.1063/1.5045491 · Cited by 2
Self-citationSchley, R., USDOE Office of Nuclear Energy (NE), Aagesen, L. K., Hua, Z., & Hurley, D. H. (2019) · doi:10.2172/1567704 · Cited by 2
Madden, N., Briggs, S. A., Perales, D., Boyle, T. J., Hattar, K., & Krogstad, J. A. (2021) · SSRN Electronic Journal · doi:10.2139/ssrn.3951050 · Cited by 2
Self-citationAurora, A., Devitre, A. R., Wylie, A. P. C., Rajagopal, J. A., & Short, M. P. (2025) · Nuclear Fusion · doi:10.1088/1741-4326/add74e · Cited by 1
“Amongst techniques such as in situ TEM [9] or in situ Raman spectroscopy [10] that can provide local structural information during irradiation, TGS is unique in its ability to continuously monitor thermal and elastic properties.”
He Bubble Evolution in LiAlO2: A Comparison of Human and Artificial Intelligence Based Analysis
Wheeler, K., Lang, E. J., Field, C. R., Madden, N., Schoell, R. M., Peña, R., Senor, D. J., Casella, A. M., & Hattar, K. (2024) · Microscopy and Microanalysis · doi:10.1093/mam/ozae044.816 · Cited by 1
Self-citationKosmidou, M., Madden, N., Briot, N. J., Krogstad, J. A., Hattar, K., & Balk, T. J. (2026) · Scripta Materialia · doi:10.1016/j.scriptamat.2026.117287 · Cited by 1
Self-citationDevelopment of the In-Situ Ion Irradiation SEM at Sandia National Laboratories
Briggs, S. A., Monterrosa, A. M., Heckman, N. M., Barr, C. M., Treadwell, L. J., Boyce, B. L., & Hattar, K. (2019) · Microscopy and Microanalysis · doi:10.1017/s1431927619008717 · Cited by 1
Self-citationClark, T., Taylor, C. A., Barr, C. M., & Hattar, K. (2022) · Journal of Visualized Experiments · doi:10.3791/61293 · Cited by 1
Self-citationStructure and Phase Stability in Extreme Environments Explored via In-situ TEM Experiments
Lang, E. J., Madden, N., Schoell, R. M., Clark, T., Adams, D. P., & Hattar, K. (2022) · Microscopy and Microanalysis · doi:10.1017/s1431927622007267 · Cited by 1
Self-citationClark, T., Taylor, C. A., Barr, C. M., & Hattar, K. (2022) · Journal of Visualized Experiments · doi:10.3791/61293-v · Cited by 1
Self-citationIn situ investigation of ion irradiation-induced amorphization of (Ge2Sb2Te5)1−xCx [0 ≤ x ≤ 0.12]
Lang, E. J., Clark, T., Schoell, R. M., Hattar, K., & Adams, D. P. (2023) · Journal of Applied Physics · doi:10.1063/5.0136748 · Cited by 1
Self-citationDesign of a beam line for simultaneous dual-beam ion implantation
Cai, S., Wang, K., Huang, W., Wang, K., Easton, M., Li, J., Zhang, C., Zhu, T., Wang, H., Ge, H., et al. (2023) · AIP Advances · doi:10.1063/5.0144431 · Cited by 1
Aurora, A., Devitre, A. R., Wylie, A. P., Rajagopal, J. A., & Short, M. P. (2025) · arXiv · doi:10.48550/arxiv.2506.17358
“Amongst techniques such as in situ TEM [9] or in situ Raman spectroscopy [10] that can provide local structural information during irradiation, TGS is unique in its ability to continuously monitor thermal and elastic properties.”
Muntifering, B. R., Qu, J., & Hattar, K. (2016) · MRS Advances · doi:10.1557/adv.2016.396
Self-citationIn Situ Electron Microscopy of Helium Bubble Implantation in Metal Hydrides
Sandia National Labs., A., Hattar, K., Administration, U. A. S. F. H. R. A., Sandia National Laboratories (SNL-CA), ;. C. L., Bufford, D. C., Robinson, D., & Snow, C. S. (2014) · doi:10.2172/1171594
Self-citationModifying germanium nanowires for future devices: an in situ TEM study
Kelly, R. A. (2016) · Cork Open Research Archive (University College Cork, Ireland)
Introductory Chapter: Basic Concept of Gold Nanoparticles
Rahman, M. M., & Asiri, A. M. (2019) · IntechOpen eBooks · doi:10.5772/intechopen.81781
In-Situ Characterization Techniques for Investigating Nuclear Materials
Hosemann, P., Frazer, D. M., Agarwal, S., & Yablinsky, C. A. (2020) · JOM · doi:10.1007/s11837-020-04130-7
Meher, S., van Rooyen, I. J., & Hattar, K. (2020) · Microscopy and Microanalysis · doi:10.1017/s143192762001613x
Self-citationBuck, E. C. (2022) · Frontiers in Nuclear Engineering · doi:10.3389/fnuen.2022.975132
Sharma, R. (2023) · doi:10.1002/9783527834822.ch1
The Physical and Engineering Limits of Coupled In situ TEM Experiments
Schoell, R. M., Lang, E. J., Wolf, B., Moore, T. M., Jungjohann, K., & Hattar, K. (2023) · Microscopy and Microanalysis · doi:10.1093/micmic/ozad067.754
Self-citationIn-situ Evaluation of Helium Bubble Migration and Coalescence in Tungsten Heavy Alloys
Lang, E. J., Tyler, S., Cunningham, S., Sprouster, D., Trelewicz, J. R., McCue, I., & Hattar, K. (2023) · Microscopy and Microanalysis · doi:10.1093/micmic/ozad067.793
Self-citationThomas, M. P., Schoell, R. M., Rasel, M. A. J., Rahman, M. H., Kuo, W. C. H., Watt, J. D., House, S. D., Hattar, K., Windes, W. E., & Haque, A. (2024) · Materials Research Express · doi:10.1088/2053-1591/ad37a6
Self-citationDevelopment of a 50 kV hydrogen–helium mixed ion beam implanter
Huang, W., Cai, S., Wang, L., Su, Y. K., & Zhu, K. (2024) · Review of Scientific Instruments · doi:10.1063/5.0200849
In Situ Tem Examination of Helium Cavity Evolution and Recrystallization in Am Refractory AlloysPreprint
Lang, E. J., Cunningham, W. S., Tyler, S., McCue, I., Trelewicz, J. R., & Hattar, K. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4899014
Self-citation
Metadata
- Authors
- Hattar, K., Bufford, D. C., & Buller, D. L.
- Affiliations
- Sandia National Laboratories (US)
- Corresponding author
- Hattar, K.
- Venue
- Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Publisher
- Elsevier BV
- Published
- 2014-11
- Volume
- 338
- Pages
- 56-65
- ISSN
- 0168-583X (ISSN-L)
- OpenAlex
- W2062199375
- Cited by
- 127
- References
- 56
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 6 · 2023: 13 · 2022: 14 · 2021: 13 · 2020: 11 · 2019: 22 · 2018: 8 · 2017: 7 · 2016: 12 · 2015: 10 · 2014: 6
- FWCI
- 6.38
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms (publishedVersion, cc-by)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- Funders
- US Department of Energy, Office of Basic Energy Sciences
- U.S. Department of Energy’s National Nuclear Security Administration (DE-AC04-94AL85000)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Structural Biology › Advanced Electron Microscopy Techniques and Applications
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Ion-surface interactions and analysis
- Physical Sciences › Materials Science › General Materials Science › Advanced Materials Characterization Techniques
- Keywords
- in situ ion irradiation, transmission electron microscopy, ion implantation, heavy ion irradiation, mechanical loading, corrosive environments
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review