Commercial fusion power plants demand magnet materials that retain structural integrity and thermal conductivity while operating under the bombardment of energetic neutrons at cryogenic temperatures. Understanding how thermo-mechanical properties evolve under such extreme loads is crucial for selecting materials with high radiation tolerance and predictable failure mechanisms. Presented here is a facility that combines cryogenic transient grating spectroscopy (TGS) with simultaneous ion irradiation, enabling in-situ measurements of thermal diffusivity and surface acoustic wave (SAW) frequency spectra. Employing copper as a benchmark material, an irradiation was performed at 30 K with 12.4 MeV $\text{Cu}^{6+}$ ions producing a final fluence of $1.9 \times 10^{17}$ ions/m$^2$. Over the irradiation period, thermal diffusivity nearly halved from an initial value of $1.2 \times 10^{-4}$ $\text{m}^2/\text{s}$ while SAW speed did not show significant change, maintaining a value of $2162\pm18$ m/s. Given its real-time monitoring capability and the numerous candidate materials that remain uncharacterized under fusion magnet operating conditions, this facility is poised to deliver new scientific insights into fusion magnet material degradation trends, contributing to improved design criteria and operational certainty for forthcoming fusion power plants.
AI snapshot
Written from the paper’s full text.
TL;DR
The paper presents a facility that combines cryogenic transient grating spectroscopy (TGS) with simultaneous ion irradiation to measure thermo-mechanical property evolution in fusion magnet materials. Using Cu-110 as a benchmark, it demonstrates in-situ thermal diffusivity and surface acoustic wave measurements during 30 K self-ion irradiation.
Key findings
- Cu-110 was irradiated at 30 K with 12.4 MeV Cu⁶⁺ ions to a final fluence of 1.9 × 10¹⁷ ions/m², equivalent to 21 mdpa.
- Thermal diffusivity nearly halved from an initial 1.2 × 10⁻⁴ m²/s, decaying to a plateau of 0.7 ± 0.22 × 10⁻⁴ m²/s.
- SAW speed showed no significant change, maintaining 2162 ± 18 m/s in the abstract; the text reports an initial 2155 ± 7.2 m/s and an average maximum of 2180 ± 8.0 m/s at 1.4 × 10¹⁷ ions/m².
- At 0.6 × 10¹⁷ ions/m², corresponding to 6 mdpa, thermal diffusivity at 30 K deteriorated by 17.9 ± 6.75%.
Methods
- The apparatus combines a cryogenic target holder, TGS optics, and an ion-beam accelerator, operating from 30 K to 300 K with a base temperature of 30 K and a 3-hour cooldown from room temperature.
- TGS used a 532 nm pump laser at 1 kHz and a 577 nm quasi-continuous probe beam; the true grating spacing was calibrated to 3.5276 µm using a {100} single-crystal tungsten reference.
- A 13 mm × 15 mm × 2 mm polycrystalline Cu-110 sample was irradiated using the MIT CLASS 1.7 MV Tandetron with 12.4 MeV Cu⁶⁺ ions at an average beam current of 0.45 nA; SRIM was used to compute displacement damage.
Limitations
- The paper states that absolute TGS calibration can be influenced by beam-spot alignment, surface impurities, and other systematic effects, and that the measured pre-irradiation diffusivity is about an order of magnitude below literature values for Cu with RRR=30.
- The paper states that localized ion beam heating can be consequential and is not fully captured by nearby temperature probes, but precise accountancy of ion beam point heating is beyond the scope of the work.
- The paper states that the analytical heat-load calculation overestimates sample temperature by approximately 10 K due to room-temperature emissivity assumptions and perfect absorptivity, and that MLI was not used in further experiments because it restricted target-holder movement during alignment.
- Evident from the text: the demonstration is limited to one benchmark material, Cu-110, and one irradiation condition, so broader material and dose-temperature trends are not established.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
23 of 55 cited sources checked · 10 supported · 1 flagged · accuracy not yet measured
- Premisecitation§ 1. Introduction · p. 3
Cu-110 was selected as a benchmark material for its crucial role in REBCO HTS magnets and cables.
“Cu-110 was selected as a benchmark material for its crucial role in REBCO HTS magnets and cables [24, 25].”
Quote in the paperSubstantial claim1 of 2 sources checked- cites [24] [24] ZS Hartwig, RF Vieira, BN Sorbom, RA Badcock, M Bajko, WK Beck, B Castaldo, CL Craighill, M Davies, J Estrada, et al. Viper: an industrially scalable high-current high-temperature superconductor cable. Superconductor Science and Technology , 33(11):11LT01, 2020. - source
The Cable design section (page unavailable) describes a copper core supporting HTS stacks and a copper former providing a heat-removal path. The Cryostability & quench section also identifies the former’s heat capacity and low electrical resistance as contributors to cable stability. These passages support an important role for copper in HTS cables, but the paper does not identify the copper as Cu-110 or establish a role for that specific grade in REBCO magnets. (LLM, conf=0.86)
Experimental — accuracy not yet measured - cites [25] [25] ZS Hartwig et al. The sparc toroidal field model coil program. IEEE Transactions on Applied Superconductivity , 34(2):1-16, 2024. - source
- Study design and conductcitation§ 2.1. Transient grating spectroscopy (TGS · p. 5
Calibration using a {100}-oriented single crystal tungsten reference specimen with SAW speed 2669.5 m/s revealed a true grating spacing of 3.5276 μm.
“Calibration using a { 100 } -oriented single crystal tungsten reference specimen (SAW speed: 2669.5 m/s) revealed a true grating spacing of 3.5276 µ m [15].”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [15] [15] CA Dennett, P Cao, SE Ferry, A Vega-Flick, AA Maznev, KA Nelson, AG Every, and MP Short. Bridging the gap to mesoscale radiation materials science with transient grating spectroscopy. Phys. Rev. B , 94:214106, 2016. - source
Section A (Experiment; page not provided) says a {001}-oriented single-crystal tungsten specimen was used to calibrate grating spacing. It gives the reference SAW speed as 2665.9 m/s, not 2669.5 m/s, and does not report a grating spacing of 3.5276 μm. (LLM, conf=0.91)
Experimental — accuracy not yet measured
- Premisecitation§ 1. Introduction · p. 2
The expected cumulative radiation dose that REBCO can withstand over its operational lifetime in fusion magnets is greater than 4 mdpa.
“This threshold is especially relevant because it is the expected cumulative radiation dose that rare-earth barium copper oxide (REBCO)-the primary constituent of hightemperature superconducting (HTS)-can withstand over their operational lifetime in fusion magnets [4].”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [4] [4] W Iliffe, N Peng, G Brittles, R Bateman, R Webb, C Grovenor, and S Speller. In-situ measurements of the effect of radiation damage on the superconducting properties of coated conductors. Superconductor Science and Technology , 34(9):09LT01, 2021. - source
The Abstract reports irradiation of GdBCO coated conductors up to 4 mdpa, and the Introduction identifies REBCO as a material for fusion magnets. Neither passage establishes that REBCO can withstand more than 4 mdpa over a magnet’s operational lifetime. The Conclusions say further work is needed to understand the practical implications for fusion magnets. (LLM, conf=0.85)
Experimental — accuracy not yet measured
- Premisecitation§ 1. Introduction · p. 2
Among techniques that provide local structural information during irradiation, such as in situ TEM and in situ Raman spectroscopy, TGS is unique in its ability to continuously monitor thermal and elastic properties.
“And amongst techniques such as in situ TEM [9] or in situ Raman spectroscopy [10] that can provide local structural information during irradiation, TGS is unique in its ability to continuously monitor thermal and elastic properties.”
Quote in the paperSubstantial claim1 of 2 sources checked- cites [9] [9] K Hattar, DC Bufford, and DL Buller. Concurrent in situ ion irradiation transmission electron microscope. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms , 338:56-65, 2014. - source
- cites [10] [10] S Miro, E Bordas, L Thom´ e, JM Costantini, F Leprˆ etre, P Trocellier, Y Serruys, L Beck, D Gosset, R Verlet, J Huguet-Garcia, M Tupin, and M Belleil. Monitoring of the microstructure of ion-irradiated nuclear ceramics by in situ raman spectroscopy. Journal of Raman Spectroscopy , 47(5):476-485, 2016. - source
- Study design and conductcitation§ 3.1. Thermal property evolution · p. 10
A two-step fitting approach improved both thermal and functional fitting sensitivity compared to existing techniques, especially in cases with noisy or rapid signal decay.
“This approach improved both thermal and functional fitting sensitivity compared to existing techniques [16, 31], especially in cases with noisy or rapid signal decay.”
Quote in the paperSubstantial claim2 of 2 sources checked- cites [16] [16] APC Wylie, KB Woller, SAA Al Dajani, BR Dacus, EJ Pickering, M Preuss, and MP Short. Thermal diffusivity in ion-irradiated single-crystal iron, chromium, vanadium, and tungsten measured using transient grating spectroscopy. Journal of Applied Physics , 132(4):045102, 2022. - source
The available passages are bibliographic metadata (section “2 Finished”) and an access-to-document listing (section “Abstract”); neither discusses fitting performance. Searches for two-step fitting, sensitivity, noise, and rapid signal decay found no passage addressing the claim. (LLM, conf=0.76)
Experimental — accuracy not yet measured - cites [31] [31] CA. Dennett and MP Short. Thermal diffusivity determination using heterodyne phase insensitive transient grating spectroscopy. Journal of Applied Physics , 123(21):215109, 2018. - source
In Results and Discussion (page unavailable), fitting with an added decaying sinusoidal term reduced variation in the fitted thermal diffusivity from 9.3% to 3.5% compared with the simpler fit. Parameter Estimation also describes preliminary fitting to improve starting values. These passages support an improvement in thermal-diffusivity fitting, but do not establish improved functional fitting sensitivity or a particular advantage for noisy or rapidly decaying signals. (LLM, conf=0.82)
Experimental — accuracy not yet measured
- Premisecitation§ 3.2. Elastic property evolution · p. 12
Previous TGS studies on copper have utilized SAW speed measurements and theory grounded in the Christoffel equation to deduce stiffness constants in monocrystal samples subjected to irradiation.
“Previous TGS studies on copper have utilized SAW speed measurements and theory grounded in the Christoffel equation to deduce stiffness constants in monocrystal samples subjected to irradiation [15, 31].”
Quote in the paperSubstantial claim2 of 2 sources checked- cites [15] [15] CA Dennett, P Cao, SE Ferry, A Vega-Flick, AA Maznev, KA Nelson, AG Every, and MP Short. Bridging the gap to mesoscale radiation materials science with transient grating spectroscopy. Phys. Rev. B , 94:214106, 2016. - source
The Experiment and Experimental results sections describe TGS measurements of SAW speeds in single-crystal copper, compared with predictions based on reference elastic constants. But the measured crystals are not described as irradiated: the paper simulates vacancies as a proof of concept, rather than using SAW measurements to deduce stiffness constants in irradiated samples. Its Analytical SAW velocity calculation starts with elastic constants to predict wave speeds; the copy does not name the Christoffel equation. (LLM, conf=0.88)
Experimental — accuracy not yet measured - cites [31] [31] CA. Dennett and MP Short. Thermal diffusivity determination using heterodyne phase insensitive transient grating spectroscopy. Journal of Applied Physics , 123(21):215109, 2018. - source
The Introduction (page unavailable) describes TGS as a tool for studying irradiation effects, and the References list a TGS study of self-ion-irradiated copper. But this paper’s Methods study single-crystal germanium; our copy does not say that copper studies used SAW speeds and the Christoffel equation to deduce stiffness constants. (LLM, conf=0.82)
Experimental — accuracy not yet measured
- Findingown data§ 2.3. Cu-110 irradiation case study · p. 9
SRIM simulation of 12.4 MeV Cu6+ into Cu-110 shows that at the TGS thermal probe depth of 1.12 μm, the mean displacement damage is 21 mdpa.
“The illustrated TGS thermal probe depth (Λ /π ) reaches 1.12 µ m where the mean displacement damage is 21 mdpa.”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [33] [33] RE Stoller, MB Toloczko, GS Was, AG Certain, S Dwaraknath, and FA Garner. On the use of srim for computing radiation damage exposure. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms , 310:75-80, 2013. - source
- cites [34] [34] JF Ziegler, MD Ziegler, and JP Biersack. SRIM - The stopping and range of ions in matter (2010). Nuclear Instruments and Methods in Physics Research B , 268(11-12):1818-1823, 2010. - source
- Findingown data§ Abstract. · p. 1
The SAW speed of Cu-110 did not show significant change over the irradiation period, maintaining a value of 2162 ± 18 m/s.
“while SAW speed did not show significant change, maintaining a value of 2162 ± 18 m/s.”
- Also stated in: § 3.1. Thermal property evolution · p. 11 · plain
“SAW speed of Cu-110 as a function of ion fluence measured by TGS at 30 K, showing little significant change.”
Quote in the paperNot a substantial claim- Rests on an assumption: The sample temperature during irradiation is 30 K, or the measured temperature is representative of the irradiated region.
- Also stated in: § 3.1. Thermal property evolution · p. 11 · plain
- Findingcitation§ 3.1. Thermal property evolution · p. 9
At 30 K, the pre-irradiation thermal diffusivity of Cu-110 is 1.2 × 10^-4 m^2/s, about an order of magnitude below values reported for Cu with RRR=30 (~1 × 10^-3 m^2/s).
“At 30 K, the pre-irradiation diffusivity is 1 . 2 × 10 -4 m 2 / s-about an order of magnitude below values reported for Cu with Residual Resisitivty Ratio (RRR)=30 ( ∼ 1 × 10 -3 m 2 / s) [37].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [37] [37] P Duthil. Material properties at low temperature. In R. Bailey, editor, Proceedings of the CAS-CERN Accelerator School: Superconductivity for Accelerators, Erice, Italy, 24 April - 4 May 2013 , volume CERN-2014-005 of CERN Yellow Reports: School Proceedings , pages 77-97, Geneva, Switzerland, 2014. CERN. -
Not checked in the free run.
- Rests on an assumption: The sample temperature during irradiation is 30 K, or the measured temperature is representative of the irradiated region.
- Findingown data§ Abstract. · p. 1
Over the irradiation period, the thermal diffusivity of Cu-110 nearly halved from an initial value of 1.2 × 10^-4 m^2/s.
“Over the irradiation period, thermal diffusivity nearly halved from an initial value of 1 . 2 × 10 -4 m 2 / s”
Quote in the paperSubstantial claim- Rests on an assumption: The sample temperature during irradiation is 30 K, or the measured temperature is representative of the irradiated region.
- Findingown data§ 3.2. Elastic property evolution · p. 11
SAW speed on the TGS spot remained relatively constant over the irradiation period.
“SAW speed on the TGS spot demonstrates minimal shift over the irradiation period.”
- Also stated in: § 4. Conclusions · p. 12 · plain
“Over the irradiation period, SAW speed remained relatively constant”
Quote in the paperNot a substantial claim - Also stated in: § 4. Conclusions · p. 12 · plain
- Findingreasoning§ 4. Conclusions · p. 12
Over the irradiation period, thermal diffusivity nearly halved.
“Over the irradiation period, SAW speed remained relatively constant while thermal diffusivity nearly halved, explained by the defect-induced scattering of conduction electrons.”
Quote in the paperSubstantial claim - Findingown data§ Appendix A.2. Validation experiment · p. 16
The introduction of the ion beam did not significantly perturb the thermal equilibrium, maintaining the temperature around 24 K with minor fluctuations.
“In Figure A1b, the introduction of the ion beam did not significantly perturb the thermal equilibrium, maintaining the temperature around 24 K with minor fluctuations.”
Quote in the paperSubstantial claim - Findingown data§ Appendix A.2. Validation experiment · p. 17
Wrapping the target holder strap in MLI sheath reduced the temperature to 17 K.
“This reduced the temperature to 17 K”
Quote in the paperSubstantial claim - Findingown data§ 3.1. Thermal property evolution · p. 11
At ion fluences of 0.6×10^17 ions/m2 causing comparable order-of-magnitude displacement damage (6 mdpa), the copper sample's thermal diffusivity at 30 K deteriorates by 17.9 ± 6.75%.
“Concerningly, at ion fluences of just 0 . 6 × 10 17 ions / m 2 causing comparable order-of-magnitude displacement damage (6 mdpa), the copper sample's diffusivity at 30 K deteriorates by 17 . 9 ± 6 . 75%.”
Quote in the paperSubstantial claim - Findingnone given§ 4. Conclusions · p. 12
The in situ diagnostic system enables the characterization of property evolution as it occurs, without intermediate annealing, in the temperature range of 30 to 300 K.
“The in situ diagnostic system enables the characterization of property evolution as it occurs, without intermediate annealing, in the temperature range of 30 to 300 K.”
Quote in the paperSubstantial claim - Findingown data§ 3.1. Thermal property evolution · p. 10
Error bars and global trend fluctuations in the data indicate thermal fitting uncertainty in the TGS signals.
“Error bars and global trend fluctuations in the data indicate thermal fitting uncertainty in the TGS signals.”
Quote in the paperNot a substantial claim - Findingown data§ Appendix A.1. Analytical calculation · p. 14
The numerical solution of the heat load equation consistently produced a sample temperature T_S = 26.64 K.
“Using the SciPy toolkit's Levenberg-Marquardt algorithm, this equation was solved numerically for several initial values and consistently produced, T S = 26 . 64 K.”
Quote in the paperNot a substantial claim - Findingown data§ 2.3. Cu-110 irradiation case study · p. 9
The TGS thermal probe depth (Λ/π) reaches 1.12 μm.
“The illustrated TGS thermal probe depth (Λ /π ) reaches 1.12 µ m”
Quote in the paperNot a substantial claim - Findingown data§ 3.2. Elastic property evolution · p. 11
The SAW speed reaches an average maximum of 2180 ± 8.0 m/s at a fluence of 1.4×10^17 ions/m2 before restabilizing.
“At this point, a more slight rise initiates, with the SAW speed reaching an average maximum of 2180 ± 8 . 0 m/s at a fluence of 1 . 4 × 10 17 ions/m 2 before restabilizing.”
Quote in the paperNot a substantial claim - Premisecitation§ 1. Introduction · p. 2
The temperature at which irradiation occurs influences the resulting defect structures formed in the material.
“Secondly, the temperature at which irradiation occurs influences the resulting defect structures formed in the material.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [23] [23] BS Brown. Radiation effects in superconducting fusion-magnet materials. Journal of Nuclear Materials , 97(1-2):1-14, 1981. -
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Study design and conductnone given§ 1. Introduction · p. 3
This work introduces an apparatus constructed specifically for variable-temperature TGS, ranging between 30 K and 300 K.
“This work introduces an apparatus constructed specifically for variable-temperature TGS, ranging between 30 K and 300 K.”
Quote in the paperSubstantial claim - Study design and conductown data§ 2.2. Cryogenic target holder · p. 7
Analytical calculations and experimental cooldown results confirm that the TGS beam's contribution to bulk sample temperature is negligible compared to the dominant radiative heat load.
“Analytical calculations and experimental cooldown results (detailed in Appendix A) confirm that the TGS beam's contribution to bulk sample temperature is negligible compared to the dominant radiative heat load.”
Quote in the paperSubstantial claim - Interpretationreasoning§ 2.1. Transient grating spectroscopy (TGS · p. 3
TGS's sensitivity to micron-scale features makes it well-suited for examining material degradation under ion irradiation, where damage typically manifests at comparable spatial scales.
“Its sensitivity to micron-scale features makes TGS particularly well-suited for examining material degradation under ion irradiation, where damage typically manifests at comparable spatial scales.”
Quote in the paperSubstantial claim - Premisecitation§ 1. Introduction · p. 2
Only irradiations performed near the operating temperature of the magnet are unambiguous and useful for predicting changes in magnet material properties.
“Therefore, only irradiations performed near the operating temperature of the magnet are unambiguous and, thus, useful for predicting changes in magnet material properties [3].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [3] [3] AR Devitre, DX Fischer, KB Woller, BC Clark, MP Short, DG Whyte, and ZS Hartwig. A facility for cryogenic ion irradiation and in situ characterization of rare-earth barium copper oxide superconducting tapes. Review of Scientific Instruments , 95(6):063907, 2024. - source
- Interpretationreasoning§ 1. Introduction · p. 2
Simultaneous measurement enables high-resolution mapping of temperature-dose-property relationships at a fidelity and speed previously unattainable with more traditional ex situ methods.
“Finally, simultaneous measurement enables high-resolution mapping of temperaturedose-property relationships, at a fidelity and speed previously unattainable with more traditional ex situ methods.”
Quote in the paperSubstantial claim - Premisecitation§ 3.1. Thermal property evolution · p. 9
In metals, point defects act as scattering centers for free electrons, leading to a reduction in electrical conductivity as the density of point defects increases.
“In metals, point defects act as scattering centers for free electrons, leading to a reduction in electrical conductivity, σ , as the density of point defects increases within the crystalline microstructure [40].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [40] [40] E Trachanas, A Bignami, N Gazis, APC Wylie, KB Woller, BR Dacus, MP Short, E Gazis, and G Fikioris. Thermal diffusivity variation assessment on radiofrequency quadrupole cu-of copper due to proton irradiation. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms , 539:179-189, 2023. - source
- Interpretationreasoning§ 3.1. Thermal property evolution · p. 10
Thermal fitting uncertainty is exacerbated in copper samples due to its high thermal diffusivity amongst metals, which results in fast decay of the thermal grating and a short signal lifetime.
“This uncertainty is exacerbated in copper samples due to its high thermal diffusivity amongst the metals, which results in fast decay of the thermal grating and a short signal lifetime.”
Quote in the paperSubstantial claim - Interpretationown data§ 3.2. Elastic property evolution · p. 12
The magnitude of the microstructural changes falls below the sensitivity threshold of the TGS probe, making them undetectable.
“However, the magnitude of these microstructural changes falls below the sensitivity threshold of the TGS probe, making them undetectable.”
Quote in the paperNot a substantial claim- Rests on an assumption: In metals and alloys like Cu-110, irradiation-induced lattice vacancies and interstitials form defect clusters within the microstructure.
- Rests on an assumption: A high cluster density impedes the motion and slip of dislocations within the crystal lattice.
- Interpretationreasoning§ 3.1. Thermal property evolution · p. 9
A reduction in electrical conductivity is directly associated with a decrease in thermal diffusivity.
“a reduction in electrical conductivity is directly associated with a decrease in thermal diffusivity.”
Quote in the paperSubstantial claim - Premisecitation§ 3.2. Elastic property evolution · p. 12
In metals, dislocation loops are the primary mechanism of plastic deformation.
“In metals, dislocation loops are the primary mechanism of plastic deformation”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [47] [47] HShulman and WS Ginell. Nuclear and space radiation effects on materials. Special Publication (SP) NASA-SP-8053, NASA, Washington, D.C., 1970. -
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [38] [38] G. S. Was. Fundamentals of Radiation Materials Science , chapter 12, pages 594597. Springer New York, NY, 2 edition, 2017. -
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Interpretationnone given§ 4. Conclusions · p. 12
The near-halving of thermal diffusivity is explained by defect-induced scattering of conduction electrons.
“explained by the defect-induced scattering of conduction electrons.”
Quote in the paperSubstantial claim - Premisecitation§ 3.2. Elastic property evolution · p. 12
Work by Du et al. using EBSD mapping has enabled the prediction of elastic constants in polycrystalline and anisotropic materials via TGS.
“Recently, work by Du et al. [48] using electron backscatter diffraction (EBSD) mapping has also enabled the prediction of elastic constants in polycrystalline and anisotropic materials via TGS.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [48] [48] X Du and JC Zhao. Facile measurement of single-crystal elastic constants from polycrystalline samples. npj Computational Materials , 3(1):17, 2017.
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Classified as probably not a substantial claim. 15
- May combine two claims. 30
Probably not a substantial claim: may not pass S3 (load-bearing).
Premisecitation§ 1. Introduction · p. 2In situ ion irradiation with TGS has been introduced to infer bulk property changes as they occur, enabling quantification of relationships between dose and void swelling, elastic moduli, and thermal diffusivity in single-crystal metals.
“Short and Dennett et al. [13, 7] introduced in situ ion irradiation with TGS to infer bulk property changes as they occur, enabling the quantification of relationships between dose and void swelling [14], elastic moduli [15], and thermal diffusivity [16] in single-crystal metals.”
Quote in the paperNot a substantial claim2 of 4 sources checked- cites [13] [13] MP Short, CA Dennett, SE Ferry, et al. Applications of transient grating spectroscopy to radiation materials science. JOM , 67(8):1840-1848, 2015. - source
- cites [7] [7] CA Dennett, DL Buller, K Hattar, and MP Short. Real-time thermomechanical property monitoring during ion beam irradiation using in situ transient grating spectroscopy. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms , 440:126-138, 2019. - source
- cites [14] [14] CA Dennett, KP So, A Kushima, DL Buller, K Hattar, and MP Short. Detecting self-ion irradiation-induced void swelling in pure copper using transient grating spectroscopy. Acta Materialia , 145:496-503, 2018. - source
The Experimental methods section explicitly says the irradiated samples were characterized ex situ using TGS. The Discussion describes in situ use as a future development, not something this paper introduced or used to quantify changes as they occurred. The later claims about dose relationships have separate citations in the citing sentence. (LLM, conf=0.88)
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measured - cites [15] [15] CA Dennett, P Cao, SE Ferry, A Vega-Flick, AA Maznev, KA Nelson, AG Every, and MP Short. Bridging the gap to mesoscale radiation materials science with transient grating spectroscopy. Phys. Rev. B , 94:214106, 2016. - source
The Introduction and Background says TGS was previously proposed for in situ monitoring during ion irradiation; this paper tests its sensitivity to small changes in surface acoustic wave speed. The Conclusions describes monitoring properties as irradiation takes place as a future development, not an in situ experiment demonstrated here. Its simulations relate vacancy concentration to acoustic response, but do not quantify dose relationships for void swelling, elastic moduli, and thermal diffusivity. (LLM, conf=0.87)
Experimental — accuracy not yet measured
May combine two claims.
Premisecitation§ 2.1. Transient grating spectroscopy (TGS · p. 3TGS is a non-contact method for characterizing changes in elastic, acoustic, and thermal transport properties, making it a powerful tool for inferring material structure evolution.
“TGS is a non-contact method for characterizing changes in elastic, acoustic, and thermal transport properties, making it a powerful tool for inferring material structure evolution [8].”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [8] [8] F Hofmann, MP Short, and CA Dennett. Transient grating spectroscopy: An ultrarapid, nondestructive materials evaluation technique. MRS Bulletin , 44:392402, 2019. - source
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Premisecitation§ 2.2. Cryogenic target holder · p. 7Localized ion beam heating effects can be consequential; the temperature rise in the beam spot is not fully captured by nearby temperature probes and requires alternative means of quantification.
“Localized ion beam heating effects, on the other hand, can be consequential; as is shown in a recent publication [32], the temperature rise in the beam spot is not fully captured by nearby temperature probes and requires alternative means of quantification.”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [32] [32] AR Devitre, DX Fischer, N Riva, M Rae, LD Kortman, KB Woller, ZL Fisher, MP Short, DG Whyte, and ZS Hartwig. Beam heating explains critical current suppression measured during ion irradiation of rebco tapes. Superconductor Science and Technology , 38(1):015005, 2025. - source
May combine two claims.
Premisecitation§ 1. Introduction · p. 2TGS provides rapid, non-destructive diagnoses of thermomechanical properties and operates on the length scales of ion irradiation damage.
“TGS is an optical technique that provides rapid diagnoses of thermomechanical properties, is inherently non-destructive, and operates on the length scales of ion irradiation damage [7, 8].”
Quote in the paperSubstantial claim1 of 2 sources checked- cites [7] [7] CA Dennett, DL Buller, K Hattar, and MP Short. Real-time thermomechanical property monitoring during ion beam irradiation using in situ transient grating spectroscopy. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms , 440:126-138, 2019. - source
- cites [8] [8] F Hofmann, MP Short, and CA Dennett. Transient grating spectroscopy: An ultrarapid, nondestructive materials evaluation technique. MRS Bulletin , 44:392402, 2019. - source
May combine two claims.
Premisecitation§ 1. Introduction · p. 2TGS enables in situ measurements during irradiation, unlike traditional ex situ approaches such as nanoindentation, X-ray diffraction, or TEM.
“Unlike traditional ex situ approaches-such as nanoindentation, X-ray diffraction, or TEM-that cannot easily operate in extreme irradiation environments, TGS enables in situ measurements.”
Quote in the paperSubstantial claim1 of 2 sources checked- cites [7] [7] CA Dennett, DL Buller, K Hattar, and MP Short. Real-time thermomechanical property monitoring during ion beam irradiation using in situ transient grating spectroscopy. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms , 440:126-138, 2019. - source
- cites [8] [8] F Hofmann, MP Short, and CA Dennett. Transient grating spectroscopy: An ultrarapid, nondestructive materials evaluation technique. MRS Bulletin , 44:392402, 2019. - source
In “Probing material evolution via elastic properties” (page unavailable), the paper describes TGS measurements made during ion-beam irradiation and contrasts them with slower traditional post-irradiation examination. It does not establish that all three named methods cannot easily operate during irradiation; it also cites in situ TEM observations. The comparison with those specific methods is therefore broader than the source supports. (LLM, conf=0.84)
Experimental — accuracy not yet measured
Probably not a substantial claim: may not pass S3 (load-bearing).
Premisecitation§ 1. Introduction · p. 3VIPER cables operating at 20 K exhibit high cryostability, benefiting from copper specific heats and thermal conductivities.
“For example, VIPER cables (operating at 20 K) exhibit high cryostability, benefiting from copper specific heats and thermal conductivities.”
Quote in the paperNot a substantial claim1 of 2 sources checked- cites [24] [24] ZS Hartwig, RF Vieira, BN Sorbom, RA Badcock, M Bajko, WK Beck, B Castaldo, CL Craighill, M Davies, J Estrada, et al. Viper: an industrially scalable high-current high-temperature superconductor cable. Superconductor Science and Technology , 33(11):11LT01, 2020. - source
- cites [25] [25] ZS Hartwig et al. The sparc toroidal field model coil program. IEEE Transactions on Applied Superconductivity , 34(2):1-16, 2024. - source
May combine two claims.
Premisecitation§ 1. Introduction · p. 2The relevant literature has primarily focused on the electrical properties of magnet materials, leaving a notable gap in understanding thermo-mechanical property evolution under fusion power plant operating conditions.
“The relevant literature has primarily focused on the electrical properties of magnet materials [3, 4, 5], leaving a notable gap in the understanding of thermo-mechanical property evolution under FPP operating conditions.”
Quote in the paperSubstantial claim2 of 3 sources checked- cites [3] [3] AR Devitre, DX Fischer, KB Woller, BC Clark, MP Short, DG Whyte, and ZS Hartwig. A facility for cryogenic ion irradiation and in situ characterization of rare-earth barium copper oxide superconducting tapes. Review of Scientific Instruments , 95(6):063907, 2024. - source
- cites [4] [4] W Iliffe, N Peng, G Brittles, R Bateman, R Webb, C Grovenor, and S Speller. In-situ measurements of the effect of radiation damage on the superconducting properties of coated conductors. Superconductor Science and Technology , 34(9):09LT01, 2021. - source
- cites [5] [5] DX Fischer, R Prokopec, J Emhofer, and M Eisterer. The effect of fast neutron irradiation on the superconducting properties of rebco coated conductors with and without artificial pinning centers. Superconductor Science and Technology , 31(4):044006, 2018. - source
Probably not a substantial claim: may not pass S3 (load-bearing).
Premisecitation§ 1. Introduction · p. 2Prior art on cryogenic TGS investigated thermal, spin, and acoustic transport property evolution in several solid-state materials.
“Separately, prior art on cryogenic TGS investigated thermal [17], spin [18], and acoustic [19, 20] transport property evolution in several solid-state materials [21].”
Quote in the paperNot a substantial claim2 of 4 sources checked- cites [17] [17] DM Pennington and CB Harris. Dynamics of surface thermal expansion and diffusivity using two-color reflection transient gratings. In Proc. SPIE 1856, Laser Radiation Photophysics , 1993. - source
- cites [18] [18] F Mahmood, Z Alpichshev, YH Lee, J Kong, and N Gedik. Observation of exciton-exciton interaction mediated valley depolarization in monolayer MoSe2. Nano Letters , 18(1):223-228, 2018. - source
- cites [19] [19] K Kim. Investigation of Transport Phenomena of Thermal Acoustic Excitations in Semi-Crystalline and Amorphous Materials Using Transient Grating Spectroscopy . Dissertation, California Institute of Technology, 2021. -
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [20] [20] S Huberman et al. Observation of second sound in graphite at temperatures above 100 k. Science , 364:375-379, 2019. - source
May combine two claims.
Findingcitation§ 3.1. Thermal property evolution · p. 9Thermal diffusivity of Cu-110 decreases as radiation damage accumulates, consistent with previous high-temperature irradiation studies on copper and other mono-atomic metals.
“Consistent with previous high-temperature irradiation studies on copper [35] and other mono-atomic metals [16, 36], thermal diffusivity decreases as radiation damage accumulates (Figure 5).”
Quote in the paperNot a substantial claim1 of 3 sources checked- cites [35] [35] E Trachanas, A Wylie, A Bignami, N Gazis, MP Short, K Michel, C Alwmark, E Gazis, G Fikioris, and H Danared. Study of thermal diffusivity degradation on cu-ofe copper due to proton and self-ion irradiation using in situ transient grating spectroscopy. Journal of Nuclear Materials , 607:155674, 2025. - source
- cites [16] [16] APC Wylie, KB Woller, SAA Al Dajani, BR Dacus, EJ Pickering, M Preuss, and MP Short. Thermal diffusivity in ion-irradiated single-crystal iron, chromium, vanadium, and tungsten measured using transient grating spectroscopy. Journal of Applied Physics , 132(4):045102, 2022. - source
The title and bibliographic entry (section ‘2 Finished’; no page given) identify a study of thermal diffusivity in ion-irradiated iron, chromium, vanadium, and tungsten, but provide no findings. Searches for a dose-dependent decrease and high-temperature irradiation returned no results passages, so our copy cannot verify the trend attributed to this source. (LLM, conf=0.70)
Experimental — accuracy not yet measured - cites [36] [36] J Habainy, Y Dai, Y Lee, and S Iyengar. Thermal diffusivity of tungsten irradiated with protons up to 5.8 dpa. Journal of Nuclear Materials , 509:152-157, 2018. - source
- Rests on an assumption: The sample temperature during irradiation is 30 K, or the measured temperature is representative of the irradiated region.
Probably not a substantial claim: may not pass S3 (load-bearing).
Premisecitation§ 1. Introduction · p. 2TGS has previously been employed in tandem with ion-beam accelerators that emulate neutron irradiation.
“Previously, TGS has been employed in tandem with ion-beam accelerators that emulate neutron irradiation [11, 12].”
Quote in the paperNot a substantial claim2 of 2 sources checked- cites [11] [11] GS Was, Z Jiao, E Getto, K Sun, AM Monterrosa, SA Maloy, O Anderoglu, BH Sencer, and M Hackett. Emulation of reactor irradiation damage using ion beams. Scripta Materialia , 88:33-36, 2014. - source
The paper’s Abstract says ion irradiation can serve as a surrogate for neutron irradiation and describes accelerator-based experiments that emulate reactor damage. It does not mention TGS or show that TGS was employed alongside an ion-beam accelerator; searches for TGS and transient grating spectroscopy found no such passage. The page number is unavailable in our copy. (LLM, conf=0.86)
Experimental — accuracy not yet measured - cites [12] [12] F Hofmann, D Mason, J Eliason, et al. Non-contact measurement of thermal diffusivity in ion-implanted nuclear materials. Scientific Reports , 5:16042, 2015. - source
May combine two claims.
Premisecitation§ 3.1. Thermal property evolution · p. 11Reasonable radiation operation limits for copper in YBCO HTS magnets are fast neutron fluences up to 2×10^21 n/m2, corresponding to damage levels in the range of mdpa.
“Reasonable radiation operation limits for copper in Yttrium Barium Copper-Oxide (YBCO) HTS magnets are fast neutron fluences up to 2 × 10 21 n / m 2 , corresponding to damage levels in the range of mdpa [43].”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [43] [43] Y Zhai, P Titus, C Kessel, and L El-Guebaly. Conceptual magnet design study for fusion nuclear science facility. Fusion Engineering and Design , 135, Part B:324-336, 2018. - source
Table 10 in §8, Radiation Limits (p. 7), lists a fast-neutron-fluence limit of 2×10^21 n/m² for copper in the paper’s discussion of magnet materials. The paper does not state that this fluence corresponds to damage in the mdpa range; that part of the claim is unsupported by our copy. (LLM, conf=0.88)
Experimental — accuracy not yet measured
May combine two claims.
Findingown data§ 2.3. Cu-110 irradiation case study · p. 8Irradiation of Cu-110 with 12.4 MeV Cu6+ ions at 30 K for 30 minutes resulted in a total fluence of 1.9 × 10^17 ions/m^2, equivalent to 21 mdpa.
“Irradiation commenced alongside TGS at 30 K for 30 minutes, resulting in a total fluence of 1 . 9 × 10 17 ions/m 2 , equivalent to 21 mdpa (as detailed in Appendix B).”
Quote in the paperSubstantial claim- Rests on an assumption: The sample temperature during irradiation is 30 K, or the measured temperature is representative of the irradiated region.
May combine two claims.
Findingown data§ Appendix A.2. Validation experiment · p. 16Both curve conditions exhibit similar cooldown rates, reaching a base temperature of 24 ± 1 K.
“As shown in Figure A1a, both curve conditions exhibit similar cooldown rates, reaching a base temperature of 24 ± 1 K.”
Quote in the paperSubstantial claimMay combine two claims.
Findingown data§ 3.2. Elastic property evolution · p. 11Initially, the SAW speed is 2155 ± 7.2 m/s and remains relatively constant until reaching a fluence of 0.6×10^17 ions/m2.
“Initially, the SAW speed is 2155 ± 7 . 2 m/s and remains relatively constant until reaching a fluence of 0 . 6 × 10 17 ions/m 2 .”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown data§ 3.1. Thermal property evolution · p. 9As ion fluence increases, the measured thermal diffusivity of Cu-110 at 30 K decays, nearly halving at 1.35 × 10^17 ions/m^2 and plateauing afterwards at 0.7 ± 0.22 × 10^-4 m^2/s.
“As ion fluence increases, the measured diffusivity decays-nearly halving at 1 . 35 × 10 17 ions / m 2 and plateauing afterwards at 0 . 7 ± 0 . 22 × 10 -4 m 2 / s.”
Quote in the paperSubstantial claim- Rests on an assumption: The sample temperature during irradiation is 30 K, or the measured temperature is representative of the irradiated region.
May combine two claims.
Findingreasoning§ Appendix A.1. Analytical calculation · p. 14The heat load components were Q_cd = 0.354 W, Q_rd = 8.656 W, and Q_H = 9.02 W.
“Plugging back into the heat load expressions, it was determined that Q cd = 0 . 354 W, Q rd = 8 . 656 W, and Q H = 9 . 02 W.”
Quote in the paperSubstantial claim- The authors state this as an assumption: The TGS and ion beams are perfectly absorbed by the target holder.
- The authors state this as an assumption: The convective heat load is negligible because the system is in high vacuum.
- The authors state this as an assumption: Black-body radiation from the vacuum chamber interior walls is the driving radiative load.
- The authors state this as an assumption: The cylindrical vacuum chamber can be approximated as a sphere with an equivalent diameter.
May combine two claims.
Findingown data§ 4. Conclusions · p. 12We have built and tested a cryogenic target holder where the evolution of fusion magnet materials under irradiation can be assessed via non-contact measurements of thermal diffusivity and SAW speed.
“We have built and tested a cryogenic target holder where the evolution of fusion magnet materials under irradiation can be assessed via non-contact measurements of thermal diffusivity and SAW speed.”
Quote in the paperSubstantial claimMay combine two claims.
Findingreasoning§ Appendix B. Irradiation damage calculation · p. 17During the irradiation experiment, the average beam current was 0.45 nA, making the final fluence 1.9×10^17 ions/m2.
“During the irradiation experiment, the average beam current was 0.45 nA, making the final fluence 1 . 9 × 10 17 ions / m 2 .”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown data§ Appendix A.1. Analytical calculation · p. 14The dominant heat load is radiative while contributions from conduction, the TGS beam, and the ion beam are comparatively negligible.
“Here, it becomes evident that the dominant heat load is radiative while contributions from conduction, the TGS beam, and the ion beam are comparatively negligible.”
Quote in the paperNot a substantial claim- The authors state this as an assumption: The TGS and ion beams are perfectly absorbed by the target holder.
- The authors state this as an assumption: The convective heat load is negligible because the system is in high vacuum.
- The authors state this as an assumption: Black-body radiation from the vacuum chamber interior walls is the driving radiative load.
- The authors state this as an assumption: The cylindrical vacuum chamber can be approximated as a sphere with an equivalent diameter.
May combine two claims.
Interpretationcitation§ 1. Introduction · p. 2Developing cryogenic TGS with simultaneous irradiation enables coupled analysis of material evolution under fusion magnet operating conditions, specifically temperatures less than 30 K and irradiation doses greater than 4 mdpa.
“First, it enables the coupled analysis of material evolution under fusion magnet operating conditions, specifically temperatures less than 30 K [22] and irradiation doses greater than 4 millidisplacements per atom (mdpa).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [22] [22] R Mumgaard, D Whyte, M Greenwald, Z Hartwig, D Brunner, B Sorbom, E Marmar, J Minervini, P Bonoli, J Irby, B Labombard, J Terry, R Vieira, and S Wukitch. The High Field Path to Practical Fusion Energy. In APS Division of Plasma Physics Meeting Abstracts , volume 2017 of APS Meeting Abstracts , page JP11.081, 2017. -
Not checked in the free run.
May combine two claims.
Study design and conductnone given§ 2.2. Cryogenic target holder · p. 7The system achieves a base temperature of 30 K with a cooldown time of 3 hours from room temperature.
“The system achieves a base temperature of 30 K with a cooldown time of 3 hours from room temperature.”
Quote in the paperNot a substantial claimMay combine two claims.
Premisecitation§ 1. Introduction · p. 3Copper cryo-stability is not guaranteed under irradiation, and copper alloys have demonstrated severe thermal diffusivity degradation and embrittlement post-cryogenic irradiation.
“But these notions of copper cryo-stability are not guaranteed under the effects of irradiation, and copper alloys have demonstrated severe thermal diffusivity degradation and embrittlement post-cryogenic irradiation [27].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [27] [27] SA Fabritsiev, AS Pokrovsky, SJ Zinkle, and DJ Edwards. Low-temperature radiation embrittlement of copper alloys. Journal of Nuclear Materials , 233237(Part 1):513-518, 1996. - source
May combine two claims.
Study design and conductnone given§ Abstract. · p. 1The facility combines cryogenic transient grating spectroscopy (TGS) with simultaneous ion irradiation, enabling in-situ measurements of thermal diffusivity and surface acoustic wave (SAW) frequency spectra.
“Presented here is a facility that combines cryogenic transient grating spectroscopy (TGS) with simultaneous ion irradiation, enabling in-situ measurements of thermal diffusivity and surface acoustic wave (SAW) frequency spectra.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Premisecitation§ 1. Introduction · p. 3Within REBCO tapes, the copper stabilizing layer serves as a quench protection mechanism by dissipating heat and providing an alternative current path during transient events.
“Within the constituent REBCO tapes, the copper stabilizing layer also serves as a quench protection mechanism by dissipating heat and providing an alternative current path during transient events [26].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [26] [26] Y Fu, O Tsukamoto, and M Furuse. Copper stabilization of ybco coated conductor for quench protection. IEEE Transactions on Applied Superconductivity , 13(2):1780-1783, 2003. - source
May combine two claims.
Interpretationreasoning§ 3.1. Thermal property evolution · p. 9The discrepancy between measured pre-irradiation diffusivity and literature values likely reflects that TGS's sensitivity is beneficial for detecting relative changes in diffusivity, whereas its absolute calibration can be influenced by beam-spot alignment, surface impurities, and other systematic effects.
“This discrepancy likely reflects how TGS's sensitivity is beneficial for detecting relative changes in diffusivity, whereas its absolute calibration can be influenced by beam-spot alignment, surface impurities, and other systematic effects.”
Quote in the paperNot a substantial claimClassified as probably not a substantial claim.
Premisenone given§ 2.3. Cu-110 irradiation case study · p. 8Self-ion irradiation was chosen to avoid chemical contamination from extraneous ion implantation.
“Self-ion irradiation was chosen to avoid chemical contamination from extraneous ion implantation.”
Quote in the paperSubstantial claimMay combine two claims.
Interpretationown data§ Appendix A.2. Validation experiment · p. 17The MLI result confirms that radiative heat is the driving load and increases the base temperature.
“confirming the hypothesis that radiative heat is the driving load and increases the base temperature.”
Quote in the paperSubstantial claimMay combine two claims.
Interpretationown data§ Appendix A.2. Validation experiment · p. 16TGS beam heating marginally impacts the cooldown rate, not affecting the final base temperature, and the ion beam interaction remains thermally stable.
“These observations suggest that TGS beam heating marginally impacts the cooldown rate, not affecting the final base temperature, and the ion beam interaction remains thermally stable.”
Quote in the paperSubstantial claimMay combine two claims.
Premisecitation§ 3.2. Elastic property evolution · p. 12At cryogenic temperatures below 50 K, defect migration is minimized, meaning clusters are more stable and rarely recombine.
“At cryogenic temperatures below 50 K, defect migration is minimized, meaning clusters are more stable and rarely recombine [45, 46].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [45] [45] SJ Zinkle. Radiation-induced effects on microstructure. In R.J.M. Konings, editor, Comprehensive Nuclear Materials , volume 1, pages 65-98. Elsevier, Amsterdam, 2012. -
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [46] [46] K Wu, G Liu, P Yu, C Ye, J Shi, and Y Shen. Prediction of hardening effect by irradiation-induced vacancy clusters with dislocation dynamics. International Journal of Plasticity , 149:103160, 2022. - source
Probably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductreasoning§ 2.2. Cryogenic target holder · p. 7During experiments, the chamber is kept under vacuum in the 10^-4 Pa range to minimize convection.
“During experiments, the chamber is kept under vacuum, in the 10 -4 Pa range to minimize convection.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Premisecitation§ 3.2. Elastic property evolution · p. 12Creation of dislocation loops contributes to radiation hardening, correlating to an increase in material stiffness constants, a decrease in density, and an overall increase in SAW speed.
“their creation contributes to radiation hardening, correlating to an increase in material stiffness constants, a decrease in density, and an overall increase in SAW speed [47, 38].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [47] [47] HShulman and WS Ginell. Nuclear and space radiation effects on materials. Special Publication (SP) NASA-SP-8053, NASA, Washington, D.C., 1970. -
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [38] [38] G. S. Was. Fundamentals of Radiation Materials Science , chapter 12, pages 594597. Springer New York, NY, 2 edition, 2017. -
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Premisenone given§ 2.3. Cu-110 irradiation case study · p. 9The theoretical TGS probe region extends indefinitely, but signal contributions decrease by a factor of e at 1.12 μm.
“While the theoretical probe region extends indefinitely, signal contributions decrease by a factor of e at this depth.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Study design and conductnone given§ 2.1. Transient grating spectroscopy (TGS · p. 5The final signal used for fitting was averaged over 10,000 pulses, and a no-pump baseline reading was subtracted to minimize inherent system noise.
“The final signal used for fitting was averaged over 10,000 pulses, and a no-pump baseline reading was subtracted to minimize inherent system noise.”
Quote in the paperNot a substantial claimMay combine two claims.
Interpretationreasoning§ Appendix A.2. Validation experiment · p. 16The discrepancy between analytical calculation and experiment is likely due to the use of steel's emissivity at room temperature, which overestimates radiative heat transfer at cryogenic temperatures, and the assumption of perfect absorptivity for the target holder.
“This discrepancy is likely due to the use of steel's emissivity at room temperature, which overestimates the radiative heat transfer at cryogenic temperatures where metal emissivity typically decreases, as well as the assumption of perfect absorptivity for the target holder, further inflating Q rd and the overall heat load.”
Quote in the paperNot a substantial claim- The authors state this as an assumption: The TGS and ion beams are perfectly absorbed by the target holder.
Probably not a substantial claim: may not pass S3 (load-bearing).
Interpretationcitation§ 3.1. Thermal property evolution · p. 9The observed decrease in thermal diffusivity is possibly caused by stacking fault tetrahedra (SFT) defects, as suggested by previous room temperature, low dose irradiations.
“The observed decrease in thermal diffusivity is possibly caused by stacking fault tetrahedra (SFT) defects, as suggested by previous room temperature, low dose irradiations [38, 39].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [38] [38] G. S. Was. Fundamentals of Radiation Materials Science , chapter 12, pages 594597. Springer New York, NY, 2 edition, 2017. -
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [39] [39] N Li, K Hattar, and A Misra. In situ probing of the evolution of irradiation-induced defects in copper. Journal of Nuclear Materials , 439(1-3):185-191, 2013. - source
- Rests on an assumption: The sample temperature during irradiation is 30 K, or the measured temperature is representative of the irradiated region.
May combine two claims.
Premisecitation§ 3.1. Thermal property evolution · p. 9Electrical conductivity and thermal conductivity are interrelated by the Wiedemann-Franz Law, which holds for defected copper.
“Since electrical conductivity and thermal conductivity, κ , are interrelated by the Wiedemann-Franz Law, which holds for defected copper [41]”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [41] [41] XB Ye, ZH He, and BC Pan. The thermal conductivity of defected copper at finite temperatures. Journal of Materials Science , 55(10):4453-4463, 2020. - source
May combine two claims.
Interpretationreasoning§ 3.1. Thermal property evolution · p. 10The number of usable peaks for thermal fitting is significantly reduced in copper, an effect more pronounced at cryogenic temperatures where the TGS signal decays faster.
“Consequently, the number of usable 'peaks' for thermal fitting is significantly reduced, an effect that is even more pronounced at cryogenic temperatures, where the TGS signal decays faster.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductnone given§ 3.1. Thermal property evolution · p. 10Outliers were removed using a chi-square test with a 95% confidence interval.
“Outliers were removed using a chi-square test with a 95% confidence interval.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductnone given§ 2.3. Cu-110 irradiation case study · p. 8A beam profile monitor and quadrupole magnet system maintain a Gaussian profile broadened over a 2 mm aperture to produce a spatially uniform beam spot on the sample.
“Upstream from the accelerator beamline, a beam profile monitor and quadrupole magnet system are used to maintain a Gaussian profile broadened over a 2 mm aperture to produce a spatially uniform beam spot on the sample.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Interpretationreasoning§ 3.1. Thermal property evolution · p. 9TGS could be used as a non-contact method for resistivity recovery experiments.
“This raises the possibility of using TGS as a non-contact method for resistivity recovery experiments, which has been one of the workhorses of radiation material science [42].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [42] [42] B G´ omez-Ferrer. Resistivity Recovery in Fe and FeCr Alloys . Springer Briefs in Applied Sciences and Technology, Berlin, Germany, 2016. -
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
The paper relies on this without support.
TGS has never been used at cryogenic temperatures with simultaneous irradiation.
“However, to our knowledge, TGS has never been used at cryogenic temperatures with simultaneous irradiation.”
The paper relies on this without support.
The sample temperature during irradiation is 30 K, or the measured temperature is representative of the irradiated region.
“Irradiation commenced alongside TGS at 30 K for 30 minutes”
The paper relies on this without support.
In metals and alloys like Cu-110, irradiation-induced lattice vacancies and interstitials form defect clusters within the microstructure.
“In metals and alloys like Cu-110, irradiation-induced lattice vacancies and interstitials form defect clusters within the microstructure.”
The paper relies on this without support.
A high cluster density impedes the motion and slip of dislocations within the crystal lattice.
“A high cluster density impedes the motion and slip of dislocations within the crystal lattice.”
The authors state this as an assumption.
The TGS and ion beams are perfectly absorbed by the target holder.
“The heat loads of the TGS, Q tgs , and ion beam, Q ion , are characterized based on their respective experimental parameters, with the assumption of perfect absorption.”
The authors state this as an assumption.
The convective heat load is negligible because the system is in high vacuum.
“For Q cv , the load is assumed to be negligible since the system is in high vacuum on the order of 10 -4 Pa,”
The authors state this as an assumption.
Black-body radiation from the vacuum chamber interior walls is the driving radiative load.
“For Q rd , black-body radiation from the vacuum chamber interior walls is assumed to be driving and the Stefan-Boltzmann law is applied.”
The authors state this as an assumption.
The cylindrical vacuum chamber can be approximated as a sphere with an equivalent diameter.
“The cylindrical vacuum chamber is approximated as a sphere with an equivalent diameter and the emissivity of 316LN stainless steel at room temperature ( ϵ = 0 . 16) is used,”
Cites
SRIM – The stopping and range of ions in matter (2010)
Ziegler, J. F., Ziegler, M. D., & Biersack, J. P. (2010) · Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2010.02.091 · Cited by 11,412 · cited 1× · see citing works
“Based on the aforementioned parameters and following the ASTM-recommended 30 eV Cu displacement threshold energy of and the quick Kinchin–Pease damage model, a SRIM simulation was conducted on a single 3 µ m layer of Cu at an incidence angle of 45 ◦ with 100 000 ions [34, 35].”
On the use of SRIM for computing radiation damage exposure
Stoller, R. E., Toloczko, M. B., Was, G. S., Certain, A. G., Dwaraknath, S., & Garner, F. A. (2013) · Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2013.05.008 · Cited by 1,596 · cited 1× · see citing works
“Based on the aforementioned parameters and following the ASTM-recommended 30 eV Cu displacement threshold energy of and the quick Kinchin–Pease damage model, a SRIM simulation was conducted on a single 3 µ m layer of Cu at an incidence angle of 45 ◦ with 100 000 ions [34, 35].”
Knaster, J., Möslang, A., & Muroga, T. (2016) · Nature Physics · doi:10.1038/nphys3735 · Cited by 557 · cited 1× · see citing works
“…safety and reliability under large cyclic and transient stresses typical of a FPP, (2) assessing these materials’ performance degradation, (3) making data-driven engineering design decisions, and (4) deriving high-level techno-economic metrics to maximize the commercial viability of fusion [6].”
Emulation of reactor irradiation damage using ion beams
Was, G. S., Jiao, Z., Getto, E., Sun, K., Monterrosa, A. M., Maloy, S. A., Anderoglu, O., Sencer, B. H., & Hackett, M. (2014) · Scripta Materialia · doi:10.1016/j.scriptamat.2014.06.003 · Cited by 336 · cited 1× · see citing works
“Previously, TGS has been employed in tandem with ion beam accelerators that emulate neutron irradiation [11, 12].”
Observation of second sound in graphite at temperatures above 100 K
Huberman, S., Duncan, R. A., Chen, K., Song, B., Chiloyan, V., Ding, Z., Maznev, A. A., Chen, G., & Nelson, K. A. (2019) · Science · doi:10.1126/science.aav3548 · Cited by 297 · cited 1× · see citing works
“Separately, prior art on cryogenic TGS investigated thermal [17], spin [18], and acoustic [19, 20] transport property evolution in several solid-state materials [21].”
Optical heterodyne detection of laser-induced gratings.
Maznev, A., Nelson, K., & Rogers, J. A. (1998) · Optics Letters · doi:10.1364/ol.23.001319 · Cited by 289 · cited 1× · see citing works
“In this experiment, the intensity of the diffracted probe beam is spatially overlapped with a reference beam reflected from the sample surface and used in a di-homodyne amplification scheme (figure 1( b )) [30].”
VIPER: an industrially scalable high-current high-temperature superconductor cable
Hartwig, Z. S., Vieira, R. F., Sorbom, B. N., Badcock, R. A., Bajko, M., Beck, W. K., Castaldo, B., Craighill, C. L., Davies, M., Estrada, J., et al. (2020) · Superconductor Science and Technology · doi:10.1088/1361-6668/abb8c0 · Cited by 268 · cited 1× · see citing works
“Cu-110 was selected as a benchmark material for its crucial role in REBCO HTS magnets and cables [25, 26].”
The SPARC toroidal field model coil program
Hartwig, Z. S., Vieira, R. F., Dunn, D., Golfinopoulos, T., LaBombard, B., Lammi, C. J., Michael, P. C., Agabian, S., Arsenault, D., Barnett, R., et al. (2024) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2023.3332613 · Cited by 192 · cited 1× · see citing works
“Cu-110 was selected as a benchmark material for its crucial role in REBCO HTS magnets and cables [25, 26].”
Transient thermal gratings at surfaces for thermal characterization of bulk materials and thin films
K�ding, O. W., Skurk, H., Maznev, A. A., & Matthias, E. (1995) · Applied Physics A · doi:10.1007/bf01538190 · Cited by 141 · cited 2× · see citing works
“The decay of the thermal grating and SAW propagation is continuously monitored using a probe laser beam dif-fracted from the transient grating [29].”
Fischer, D. X., Prokopec, R., Emhofer, J., & Eisterer, M. (2018) · Superconductor Science and Technology · doi:10.1088/1361-6668/aaadf2 · Cited by 138 · cited 1× · see citing works
“The relevant literature has primarily focused on the electrical properties of magnet materials [3–5], leaving a notable gap in the understanding of thermo-mechanical property evolution under FPP operating conditions.”
Concurrent in situ ion irradiation transmission electron microscope
Hattar, K., Bufford, D. C., & Buller, D. L. (2014) · Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2014.08.002 · Cited by 127 · cited 1× · see citing works
“Amongst techniques such as in situ TEM [9] or in situ Raman spectroscopy [10] that can provide local structural information during irradiation, TGS is unique in its ability to continuously monitor thermal and elastic properties.”
Non-Contact Measurement of Thermal Diffusivity in Ion-Implanted Nuclear Materials
Hofmann, F., Mason, D. R., Eliason, J. K., Maznev, A. A., Nelson, K. A., & Dudarev, S. L. (2015) · Scientific Reports · doi:10.1038/srep16042 · Cited by 105 · cited 2× · see citing works
“…the pump beams relative to the sample normal, θ , with the following relationship: where λ is the optical wavelength (m) and L is the TGS thermal investigation depth (m), physically corresponding to the region (from the surface to L ) where most of the thermal diffusivity information is collected.”
Radiation-Induced Effects on Microstructure
Zinkle, S. J. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-803581-8.12075-2 · Cited by 89 · cited 1× · see citing works
“At cryogenic temperatures below 50 K, defect migration is minimized, meaning clusters are more stable and rarely recombine [46, 47].”
Material Properties at Low Temperature
Duthil, P. (2014) · CERN · doi:10.5170/cern-2014-005.77 · Cited by 81 · cited 1× · see citing works
“2 × 10 − 4 m 2 s − 1 -about an order of magnitude below values reported for Cu with residual resisitivty ratio = 30 ( ∼ 1 × 10 − 3 m 2 s − 1 ) [38].”
Transient grating spectroscopy: An ultrarapid, nondestructive materials evaluation technique
Hofmann, F., Short, M. P., & Dennett, C. A. (2019) · MRS Bulletin · doi:10.1557/mrs.2019.104 · Cited by 74 · cited 2× · see citing works
“TGS is a non-contact method for characterizing changes in elastic, acoustic, and thermal transport properties, making it a powerful tool for inferring material structure evolution [8].”
Self-citationDennett, C. A., So, K. P., Kushima, A., Buller, D. L., Hattar, K., & Short, M. P. (2018) · Acta Materialia · doi:10.1016/j.actamat.2017.12.007 · Cited by 70 · cited 1× · see citing works
“Dennett et al [7, 13] introduced in situ ion irradiation with TGS to infer bulk property changes as they occur, enabling the quantification of relationships between dose and void swelling [14], elastic moduli [15], and thermal diffusivity [16] in single crystal metals.”
Self-citationRadiation effects in superconducting fusion-magnet materials
Brown, B. S. (1981) · Journal of Nuclear Materials · doi:10.1016/0022-3115(81)90411-6 · Cited by 69 · cited 1× · see citing works
“In most cases, this defect state results in property changes that differ from those caused by low-temperature irradiation [24].”
Thermal diffusivity of tungsten irradiated with protons up to 5.8 dpa
Habainy, J., Dai, Y., Lee, Y., & Iyengar, S. (2018) · Journal of Nuclear Materials · doi:10.1016/j.jnucmat.2018.06.041 · Cited by 64 · cited 1× · see citing works
“Consistent with previous high-temperature irradiation studies on copper [36] and other mono-atomic metals [16, 37], thermal diffusivity decreases as radiation damage accumulates (figure 5).”
Mahmood, F., Alpichshev, Z., Lee, Y.-H., Kong, J., & Gedik, N. (2018) · Nano Letters · doi:10.1021/acs.nanolett.7b03953 · Cited by 60 · cited 1× · see citing works
“Separately, prior art on cryogenic TGS investigated thermal [17], spin [18], and acoustic [19, 20] transport property evolution in several solid-state materials [21].”
Thermal diffusivity determination using heterodyne phase insensitive transient grating spectroscopy
Dennett, C. A., & Short, M. P. (2018) · Journal of Applied Physics · doi:10.1063/1.5026429 · Cited by 50 · cited 3× · see citing works
“Previous TGS studies on copper have utilized SAW speed measurements and theory grounded in the Christoffel equation to deduce stiffness constants in monocrystal samples subjected to irradiation [15, 32].”
Self-citationLow-temperature radiation embrittlement of copper alloys
Fabritsiev, S. A., Pokrovsky, A. S., Zinkle, S. J., & Edwards, D. J. (1996) · Journal of Nuclear Materials · doi:10.1016/s0022-3115(96)00242-5 · Cited by 46 · cited 1× · see citing works
“But these notions of copper cryo-stability are not guaranteed under the effects of irradiation, and copper alloys have demonstrated severe thermal diffusivity degradation and embrittlement following cryogenic irradiation [28].”
InfluentialDennett, C. A., Buller, D. L., Hattar, K., & Short, M. P. (2019) · Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2018.10.025 · Cited by 43 · cited 2× · see citing works
“Dennett et al [7, 13] introduced in situ ion irradiation with TGS to infer bulk property changes as they occur, enabling the quantification of relationships between dose and void swelling [14], elastic moduli [15], and thermal diffusivity [16] in single crystal metals.”
Self-citationConceptual magnet design study for fusion nuclear science facility
Zhai, Y., Titus, P., Kessel, C., & El-Guebaly, L. (2018) · Fusion Engineering and Design · doi:10.1016/j.fusengdes.2017.06.028 · Cited by 42 · cited 1× · see citing works
“Reasonable radiation operation limits for copper in yttrium barium copper oxide (YBCO) HTS magnets are fast neutron fluences up to 2 × 10 21 nm − 2 , corresponding to damage levels in the range of mdpa [44].”
Facile measurement of single-crystal elastic constants from polycrystalline samples
Du, X., & Zhao, J.-C. (2017) · npj Computational Materials · doi:10.1038/s41524-017-0019-x · Cited by 41 · cited 1× · see citing works
“Recently, work by Du and Zhao [49] using electron backscatter diffraction mapping has also enabled the prediction of elastic constants in poly-crystalline and anisotropic materials via TGS. Integrating this characterization approach with the presented in situ cryogenic irradiation method would…”
In situ probing of the evolution of irradiation-induced defects in copper
Li, N., Hattar, K., & Misra, A. (2013) · Journal of Nuclear Materials · doi:10.1016/j.jnucmat.2013.04.013 · Cited by 40 · see citing works
Nicholls, R. J., Diaz-Moreno, S., Iliffe, W., Linden, Y., Mousavi, T., Aramini, M., Danaie, M., Grovenor, C. R. M., & Speller, S. C. (2022) · Communications Materials · doi:10.1038/s43246-022-00272-0 · Cited by 39 · cited 1× · see citing works
“The relevant literature has primarily focused on the electrical properties of magnet materials [3–5], leaving a notable gap in the understanding of thermo-mechanical property evolution under FPP operating conditions.”
Prediction of hardening effect by irradiation-induced vacancy clusters with dislocation dynamics
Wu, K., Liu, G., Yu, P., Ye, C., Shi, J., & Shen, Y. (2022) · International Journal of Plasticity · doi:10.1016/j.ijplas.2021.103160 · Cited by 39 · see citing works
Miro, S., Bordas, E., Thomé, L., Costantini, J. ‐., Leprêtre, F., Trocellier, P., Serruys, Y., Beck, L., Gosset, D., Verlet, R., et al. (2016) · Journal of Raman Spectroscopy · doi:10.1002/jrs.4837 · Cited by 38 · cited 1× · see citing works
“Amongst techniques such as in situ TEM [9] or in situ Raman spectroscopy [10] that can provide local structural information during irradiation, TGS is unique in its ability to continuously monitor thermal and elastic properties.”
Bridging the gap to mesoscale radiation materials science with transient grating spectroscopy
Dennett, C. A., Cao, P., Ferry, S. E., Vega-Flick, A., Maznev, A. A., Nelson, K. A., Every, A. G., & Short, M. P. (2016) · Physical Review B · doi:10.1103/physrevb.94.214106 · Cited by 37 · cited 3× · see citing works
“Calibration using a {100}-oriented single crystal tungsten reference specimen (SAW speed: 2669.5 m s − 1 ) revealed a true grating spacing of 3.5276 µ m [15].”
InfluentialSelf-citationCopper stabilization of YBCO coated conductor for quench protection
Fu, Y., Tsukamoto, O., & Furuse, M. (2003) · IEEE Transactions on Appiled Superconductivity · doi:10.1109/tasc.2003.812889 · Cited by 35 · cited 1× · see citing works
“Within the constituent REBCO tapes, the copper stabilizing layer also serves as a quench protection mechanism by dissipating heat and providing an alternative current path during transient events [27].”
Characterizing microscale energy transport in materials with transient grating spectroscopy
Choudhry, U., Kim, T., Adams, M. C., Ranasinghe, J. C., Yang, R., & Liao, B. (2021) · Journal of Applied Physics · doi:10.1063/5.0068915 · Cited by 35 · cited 1× · see citing works
“Separately, prior art on cryogenic TGS investigated thermal [17], spin [18], and acoustic [19, 20] transport property evolution in several solid-state materials [21].”
Iliffe, W., Peng, N., Brittles, G., Bateman, R., Webb, R., Grovenor, C., & Speller, S. (2021) · Superconductor Science and Technology · doi:10.1088/1361-6668/ac1523 · Cited by 34 · cited 1× · see citing works
“This threshold is especially relevant because it is the expected cumulative radiation dose that rare-earth barium copper oxide (REBCO)- the primary constituent of high-temperature superconducting (HTS)-can withstand over their operational lifetime in fusion magnets [4].”
Applications of Transient Grating Spectroscopy to Radiation Materials Science
Short, M. P., Dennett, C. A., Ferry, S. E., Yang, Y., Mishra, V. K., Eliason, J. K., Vega-Flick, A., Maznev, A. A., & Nelson, K. A. (2015) · JOM · doi:10.1007/s11837-015-1496-3 · Cited by 28 · cited 1× · see citing works
“Dennett et al [7, 13] introduced in situ ion irradiation with TGS to infer bulk property changes as they occur, enabling the quantification of relationships between dose and void swelling [14], elastic moduli [15], and thermal diffusivity [16] in single crystal metals.”
Self-citationWylie, A. P. C., Woller, K. B., Al Dajani, S. A. A., Dacus, B. R., Pickering, E. J., Preuss, M., & Short, M. P. (2022) · Journal of Applied Physics · doi:10.1063/5.0089048 · Cited by 22 · cited 3× · see citing works
“Dennett et al [7, 13] introduced in situ ion irradiation with TGS to infer bulk property changes as they occur, enabling the quantification of relationships between dose and void swelling [14], elastic moduli [15], and thermal diffusivity [16] in single crystal metals.”
Self-citationDevitre, A. R., Fischer, D. X., Woller, K. B., Clark, B. C., Short, M. P., Whyte, D. G., & Hartwig, Z. S. (2024) · Review of Scientific Instruments · doi:10.1063/5.0200936 · Cited by 15 · cited 3× · see citing works
“The MIT CLASS accelerator, a 1.7 MV Tandetron with a source of negative ions by cesium sputtering (SNICS), was utilized for the irradiation [3].”
InfluentialSelf-citationInfluence of irradiation temperature on REBCO tape degradation
Fischer, D. X., Devitre, A. R., Woller, K. B., Fisher, Z. L., Whyte, D. G., & Hartwig, Z. S. (2025) · Superconductor Science and Technology · doi:10.1088/1361-6668/ada112 · Cited by 14 · cited 1× · see citing works
“If an irradiation occurs above the migration temperature of a defect, then defects can move about during the irradiation and possibly annihilate or agglomerate [23].”
Self-citationThe thermal conductivity of defected copper at finite temperatures
Ye, X. B., He, Z. H., & Pan, B. C. (2020) · Journal of Materials Science · doi:10.1007/s10853-019-04267-0 · Cited by 7 · cited 1× · see citing works
“Since electrical conductivity and thermal conductivity, κ , are interrelated by the Wiedemann–Franz law, which holds for defected copper [42], a reduction in electrical conductivity is directly associated with a decrease in thermal diffusivity.”
Beam heating explains critical current suppression measured during ion irradiation of REBCO tapes
Devitre, A. R., Fischer, D. X., Riva, N., Rae, M., Kortman, L. D., Woller, K. B., Fisher, Z. L., Short, M. P., Whyte, D. G., & Hartwig, Z. S. (2025) · Superconductor Science and Technology · doi:10.1088/1361-6668/ad95c2 · Cited by 6 · cited 1× · see citing works
“Localized ion beam heating effects, on the other hand, can be consequential; as is shown in a recent publication [33], the temperature rise in the beam spot is not fully captured by nearby temperature probes and requires alternative means of quantification.”
Self-citationThermal diffusivity, microstructure and nanohardness of laser-welded proton-irradiated Eurofer97
Wylie, A. P. C., Reza, A., Harrison, G., Taylor, M., Dacus, B. R., Hofmann, F., Short, M. P., Kirk, S., Preuss, M., & Pickering, E. J. (2023) · Journal of Nuclear Materials · doi:10.1016/j.jnucmat.2023.154661 · Cited by 6 · cited 1× · see citing works
“Reprinted from [31], Copyright (2023), with permission from Elsevier.”
Self-citationTrachanas, E., Wylie, A., Bignami, A., Gazis, N., Short, M. P., Michel, K., Alwmark, C., Gazis, E., Fikioris, G., & Danared, H. (2025) · Journal of Nuclear Materials · doi:10.1016/j.jnucmat.2025.155674 · Cited by 5 · cited 1× · see citing works
“Consistent with previous high-temperature irradiation studies on copper [36] and other mono-atomic metals [16, 37], thermal diffusivity decreases as radiation damage accumulates (figure 5).”
Self-citationFusion magnet quench risk increase with irradiation damage
John, J. M., Gilbert, M. R., & Hardie, C. D. (2025) · Nuclear Fusion · doi:10.1088/1741-4326/adb319 · Cited by 5 · cited 1× · see citing works
“These initial findings indicate that more comprehensive property evolution studies are necessary to prove existing assumptions regarding cop-per’s cryostability and quench protection candidacy under cryogenic irradiation [45].”
In Situ Probing of the Evolution of Irradiation-induced Defects in Copper
Li, N., Hattar, K., & Misra, A. (2015) · Microscopy and Microanalysis · doi:10.1017/s1431927615003013 · Cited by 4 · cited 1×
“The observed decrease in thermal diffusivity is possibly caused by stacking fault tetra-hedra defects, as suggested by previous room temperature, low dose irradiations [39, 40].”
Resistivity Recovery in Fe and FeCr alloys
Gómez-Ferrer, B. (2016) · SpringerBriefs in Applied Sciences and Technology · doi:10.1007/978-3-319-38857-1 · Cited by 4 · cited 1× · see citing works
“This raises the possibility of using TGS as a non-contact method for resistivity recovery experiments, which has been one of the workhorses of radiation materials science [43].”
Trachanas, E., Bignami, A., Gazis, N., Wylie, A. P. C., Woller, K. B., Dacus, B. R., Short, M. P., Gazis, E., & Fikioris, G. (2023) · Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2023.04.002 · Cited by 4 · cited 1× · see citing works
“In metals, point defects act as scattering centers for free electrons, leading to a reduction in electrical conductivity, σ , as the density of point defects increases within the crystalline microstructure [41].”
Self-citationThe lifetime of components in a fusion reactor
Dose, G. (2021) · Europhysics News · doi:10.1051/epn/2021503 · Cited by 3 · cited 1× · see citing works
“Over time, neutron bombardment degrades these magnets’ ability to generate the confinement field efficiently, potentially setting the operational lifetime of the FPP itself and its ultimate return on investment [1, 2].”
Kim, T. (2021) · California Institute of Technology · doi:10.7907/k364-ga14 · Cited by 2 · see citing works
Pennington, D. M., & Harris, C. B. (1993) · SPIE Proceedings · doi:10.1117/12.147607 · Cited by 2 · cited 1× · see citing works
“Separately, prior art on cryogenic TGS investigated thermal [17], spin [18], and acoustic [19, 20] transport property evolution in several solid-state materials [21].”
Flagged first, then by citations
3 of the 50 references couldn’t be matched to a known paper.
Research works printed but not linked: 1
- [38][38] G. S. Was. Fundamentals of Radiation Materials Science , chapter 12, pages 594597. Springer New York, NY, 2 edition, 2017. -
Cited by
Sorted by citations
Vasudeva, K., Huberman, S., Wylie, A., Rae, M., Demiane, J., Botica-Artalejo, E., Trachanas, E., Haibeh, J. A., Woller, K., Short, M., et al. (2026) · PHYSICAL REVIEW MATERIALS · doi:10.1103/3pp5-d9db
Self-citationVasudeva, K., Huberman, S., Wylie, A., Rae, M., Demiane, J., Haibeh, J. A., Botica-Artalejo, E., Woller, K., Short, M. P., & Ferry, S. (2026) · doi:10.48550/arxiv.2602.23247
“TGS has been demonstrated as an effective tool to monitor changes in the thermoelastic properties of metallic materials during ion irradiation across a wide temperature range [28, 24, 25, 29].”
Self-citation
- Authors
- Aurora, A., Devitre, A. R., Wylie, A. P., Rajagopal, J. A., & Short, M. P.
- Venue
- arXiv
- Publisher
- arXiv
- Published
- 2025
- ISSN
- 2331-8422 (ISSN-L)
- arXiv
- 2506.17358
- OpenAlex
- W6929511349
- Semantic Scholar
- d475e1dd1c7a8467a03936f637d346364802d89e
- Cited by
- 0
- References
- 50
- Type
- posted content
- Language
- en
- Open access
- green
- doi.org
- Licence
- Locations
- arXiv (Cornell University) (cc-by)
- Topics
- Physical Sciences › Materials Science › Materials Chemistry › Fusion materials and technologies
- Physical Sciences › Engineering › Biomedical Engineering › Superconducting Materials and Applications
- Physical Sciences › Materials Science › Materials Chemistry › Nuclear materials and radiation effects
- Keywords
- fusion magnets, transient grating spectroscopy, thermal diffusivity, surface acoustic waves, copper, radiation damage, thermomechanical properties, in situ measurement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-10-23.
Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-10-23.
Cited sources are checked by gpt-6-sol.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review