The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Comparison of the Diagnostic Accuracies of the Spectralis, Cirrus, and RTVue Optical Coherence Tomography Devices in Glaucoma
Open accessAbstract
Purpose To compare the diagnostic accuracies of retinal nerve fiber layer (RNFL) thickness measurements obtained with Spectralis (Heidelberg Engineering, Dossenheim, Germany), Cirrus (Carl Zeiss Meditec, Dublin, CA) and RTVue (Optovue Inc, Fremont, CA) for the detection of glaucoma. Design Diagnostic, case-control study Participants Two hundred thirty three eyes (107 healthy, 126 glaucomatous) of 149 participants from the longitudinal Diagnostic Innovations in Glaucoma Study (DIGS) and from the African Descent and Glaucoma Evaluation Study (ADAGES). Methods All participants underwent retinal nerve fiber layer (RNFL) thickness imaging with Spectralis, Cirrus and RTVue in the same visit. Receiver operating characteristic (ROC) curves adjusted for age and race were obtained for quadrants (superior, nasal, inferior, temporal) and global RNFL thickness for all instruments. Areas under ROC (AUC) and sensitivities at fixed specificities (80% and 95%) were calculated and compared. Main Outcome measure Comparison of diagnostic accuracy using AUCs and sensitivities at fixed specificities of 80% and 95%. Results The RNFL thickness parameter with the largest AUCs was the superior quadrant for the Spectralis (0.88) and the global RNFL thickness for the Cirrus (0.88) and the RTVue (0.87). The pair-wise comparison among the ROC curves showed no statistical difference for all parameters except for the nasal quadrant, which had significantly larger AUC in Spectralis and RTVue compared to Cirrus (P<0.03 for both comparisons). There were no significant differences in sensitivities among the best parameters from each instrument (P>0.05). The superior quadrant thickness measured with Spectralis had sensitivity of 81.9% at a fixed specificity of 80% and 70% at a fixed specificity of 95%. The global thickness measured by the Cirrus had a sensitivity of 80.3% at a fixed specificity of 80% and 65.6% at a fixed specificity of 95%. For the RTVue, the global thickness had a sensitivity of 77.9% at a fixed specificity of 80% and 62.1% at a fixed specificity of 95%. Conclusion Although the spectral-domain OCTs have different resolution and acquisition rates, their ability to detect glaucoma was similar.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861
Moons, K. G. M., van Es, G.-A., Deckers, J. W., Habbema, J. D. F., & Grobbee, D. E. (1997) · Epidemiology · doi:10.1097/00001648-199701000-00002 · Cited by 189
Cited by
Weinreb, R. N., Leung, C. K. S., Crowston, J. G., Medeiros, F. A., Friedman, D. S., Wiggs, J. L., & Martin, K. R. (2016) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2016.67 · Cited by 632
Self-citationAsaoka, R., Murata, H., Hirasawa, K., Fujino, Y., Matsuura, M., Miki, A., Kanamoto, T., Ikeda, Y., Mori, K., Iwase, A., et al. (2019) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2018.10.007 · Cited by 254
Metadata
- Authors
- Leite, M. T., Rao, H. L., Zangwill, L. M., Weinreb, R. N., & Medeiros, F. A.
- Venue
- Ophthalmology
- Publisher
- Elsevier BV
- Published
- 2011-07
- Volume
- 118
- Issue
- 7
- Pages
- 1334-1339
- ISSN
- 0161-6420 (ISSN-L)
- OpenAlex
- W2049416620
- Cited by
- 200
- References
- 2
- FWCI
- 14.96
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of the Diagnostic Accuracies of the Spectralis, Cirrus, and RTVue Optical Coherence Tomography Devices in Glaucoma. https://app.cochat.ai/papers/10.1016/j.ophtha.2010.11.029
- The paper
- Leite, M. T., Rao, H. L., Zangwill, L. M., Weinreb, R. N., & Medeiros, F. A. (2011). Comparison of the Diagnostic Accuracies of the Spectralis, Cirrus, and RTVue Optical Coherence Tomography Devices in Glaucoma. Ophthalmology. https://doi.org/10.1016/j.ophtha.2010.11.029
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.