Purpose To compare the diagnostic accuracies of retinal nerve fiber layer (RNFL) thickness measurements obtained with Spectralis (Heidelberg Engineering, Dossenheim, Germany), Cirrus (Carl Zeiss Meditec, Dublin, CA) and RTVue (Optovue Inc, Fremont, CA) for the detection of glaucoma. Design Diagnostic, case-control study Participants Two hundred thirty three eyes (107 healthy, 126 glaucomatous) of 149 participants from the longitudinal Diagnostic Innovations in Glaucoma Study (DIGS) and from the African Descent and Glaucoma Evaluation Study (ADAGES). Methods All participants underwent retinal nerve fiber layer (RNFL) thickness imaging with Spectralis, Cirrus and RTVue in the same visit. Receiver operating characteristic (ROC) curves adjusted for age and race were obtained for quadrants (superior, nasal, inferior, temporal) and global RNFL thickness for all instruments. Areas under ROC (AUC) and sensitivities at fixed specificities (80% and 95%) were calculated and compared. Main Outcome measure Comparison of diagnostic accuracy using AUCs and sensitivities at fixed specificities of 80% and 95%. Results The RNFL thickness parameter with the largest AUCs was the superior quadrant for the Spectralis (0.88) and the global RNFL thickness for the Cirrus (0.88) and the RTVue (0.87). The pair-wise comparison among the ROC curves showed no statistical difference for all parameters except for the nasal quadrant, which had significantly larger AUC in Spectralis and RTVue compared to Cirrus (P<0.03 for both comparisons). There were no significant differences in sensitivities among the best parameters from each instrument (P>0.05). The superior quadrant thickness measured with Spectralis had sensitivity of 81.9% at a fixed specificity of 80% and 70% at a fixed specificity of 95%. The global thickness measured by the Cirrus had a sensitivity of 80.3% at a fixed specificity of 80% and 65.6% at a fixed specificity of 95%. For the RTVue, the global thickness had a sensitivity of 77.9% at a fixed specificity of 80% and 62.1% at a fixed specificity of 95%. Conclusion Although the spectral-domain OCTs have different resolution and acquisition rates, their ability to detect glaucoma was similar.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861
Statistical Methods in Diagnostic Medicine
Zhou, X., Obuchowski, N. A., & McClish, D. K. (2011) · Wiley Series in Probability and Statistics · doi:10.1002/9780470906514 · Cited by 1,784
Statistical Methods in Diagnostic Medicine
Zhou, X., Obuchowski, N. A., & McClish, D. K. (2002) · Wiley Series in Probability and Statistics · doi:10.1002/9780470317082 · Cited by 1,165
Retinal Nerve Fiber Layer Imaging with Spectral-Domain Optical Coherence Tomography
Leung, C. K.-S., Cheung, C. Y.-L., Weinreb, R. N., Qiu, Q., Liu, S., Li, H., Xu, G., Fan, N., Huang, L., Pang, C.-P., et al. (2009) · Ophthalmology · doi:10.1016/j.ophtha.2009.04.013 · Cited by 486
Self-citationLachs, M. S., Nachamkin, I., Edelstein, P. H., Goldman, J., Feinstein, A. R., & Schwartz, J. S. (1992) · Annals of Internal Medicine · doi:10.7326/0003-4819-117-2-135 · Cited by 261
Spectral domain optical coherence tomography for glaucoma (an AOS thesis).
Schuman, J. S. (2008) · PubMed Central · Cited by 248
Janes, H., & Pepe, M. S. (2008) · American Journal of Epidemiology · doi:10.1093/aje/kwn099 · Cited by 212
Distribution-free ROC analysis using binary regression techniques
Alonzo, T. A. (2002) · Biostatistics · doi:10.1093/biostatistics/3.3.421 · Cited by 203
Gonzalez-Garcia, A., Vizzeri, G., Bowd, C., Medeiros, F. A., Zangwill, L. M., & Weinreb, R. N. (2009) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2008.12.032 · Cited by 200
Self-citationKnight, O. J., Chang, R. T., Feuer, W. J., & Budenz, D. L. (2009) · Ophthalmology · doi:10.1016/j.ophtha.2008.12.032 · Cited by 199
Agreement between spectral-domain and time-domain OCT for measuring RNFL thickness
Vizzeri, G., Weinreb, R. N., Gonzalez-Garcia, A. O., Bowd, C., Medeiros, F. A., Sample, P. A., & Zangwill, L. M. (2009) · British Journal of Ophthalmology · doi:10.1136/bjo.2008.150698 · Cited by 192
Self-citationMoons, K. G. M., van Es, G.-A., Deckers, J. W., Habbema, J. D. F., & Grobbee, D. E. (1997) · Epidemiology · doi:10.1097/00001648-199701000-00002 · Cited by 189
Rao, H. L., Zangwill, L. M., Weinreb, R. N., Sample, P. A., Alencar, L. M., & Medeiros, F. A. (2010) · Ophthalmology · doi:10.1016/j.ophtha.2010.01.031 · Cited by 180
Self-citationKim, J. S., Ishikawa, H., Sung, K. R., Xu, J., Wollstein, G., Bilonick, R. A., Gabriele, M. L., Kagemann, L. E., Duker, J. S., Fujimoto, J. G., et al. (2009) · British Journal of Ophthalmology · doi:10.1136/bjo.2009.157875 · Cited by 148
Medeiros, F. A., Zangwill, L. M., Bowd, C., Sample, P. A., & Weinreb, R. N. (2005) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2005.01.003 · Cited by 135
Self-citationWu, Z., Huang, J., Dustin, L., & Sadda, S. R. (2009) · Journal of Glaucoma · doi:10.1097/ijg.0b013e31817eee20 · Cited by 124
Retinal Nerve Fiber Layer Imaging with Spectral-Domain Optical Coherence Tomography
Leung, C. K.-S., Ye, C., Weinreb, R. N., Cheung, C. Y.-L., Qiu, Q., Liu, S., Xu, G., & Lam, D. S. C. (2009) · Ophthalmology · doi:10.1016/j.ophtha.2009.06.061 · Cited by 111
Self-citationMedeiros, F. A., Vizzeri, G., Zangwill, L. M., de Alencar, L. M., Sample, P. A., & Weinreb, R. N. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2007.11.008 · Cited by 100
Self-citationEffect of Disease Severity on the Performance of Cirrus Spectral-Domain OCT for Glaucoma Diagnosis
Leite, M. T., Zangwill, L. M., Weinreb, R. N., Rao, H. L., de Alencar, L. M., Sample, P. A., & Medeiros, F. A. (2010) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.09-4716 · Cited by 92
Self-citationMoreno‐Montañés, J., Olmo, N., Alvarez, A., García, N., & Zarranz‐Ventura, J. (2010) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.08-2988 · Cited by 89
Medeiros, F. A., Sample, P. A., Zangwill, L. M., Liebmann, J. M., Girkin, C. A., & Weinreb, R. N. (2006) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.05-1441 · Cited by 81
Self-citationMedeiros, F. A., Ng, D., Zangwill, L. M., Sample, P. A., Bowd, C., & Weinreb, R. N. (2006) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.06-0618 · Cited by 71
Self-citationRao, H. L., Leite, M. T., Weinreb, R. N., Zangwill, L. M., de Alencar, L. M., Sample, P. A., & Medeiros, F. A. (2010) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.10-5546 · Cited by 68
Self-citationStandardizing Diagnostic Markers to Evaluate and Compare Their Performance
PEPE, M. S., & Longton, G. (2005) · Epidemiology · doi:10.1097/01.ede.0000173041.03470.8b · Cited by 67
Johnson, D. E., El-Defrawy, S. R., Almeida, D. R. P., & Bell, C. M. (2009) · Canadian Journal of Ophthalmology · doi:10.3129/i09-106 · Cited by 22
Cited by
Weinreb, R. N., Leung, C. K. S., Crowston, J. G., Medeiros, F. A., Friedman, D. S., Wiggs, J. L., & Martin, K. R. (2016) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2016.67 · Cited by 632
Self-citationAsaoka, R., Murata, H., Hirasawa, K., Fujino, Y., Matsuura, M., Miki, A., Kanamoto, T., Ikeda, Y., Mori, K., Iwase, A., et al. (2019) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2018.10.007 · Cited by 254
Thomas, B. J., Galor, A., Nanji, A. A., El Sayyad, F., Wang, J., Dubovy, S. R., Joag, M. G., & Karp, C. L. (2014) · The Ocular Surface · doi:10.1016/j.jtos.2013.11.001 · Cited by 184
“THE OCULAR SURFACE / JANUARY 2014, VO Nagoya, Japan) which utilizes a light source with a 1310 nm wavelength and a 16 mm-horizontal scan width– equaled the scan width of TD-OCT devices, but carried an axial resolution of only 10 mm.(22) These newer SD-OCT machines represented a marked advancement in image quality and…”
BackgroundInfluential
Metadata
- Authors
- Leite, M. T., Rao, H. L., Zangwill, L. M., Weinreb, R. N., & Medeiros, F. A.
- Venue
- Ophthalmology
- Publisher
- Elsevier BV
- Published
- 2011-07
- Volume
- 118
- Issue
- 7
- Pages
- 1334-1339
- ISSN
- 0161-6420 (ISSN-L)
- OpenAlex
- W2049416620
- Cited by
- 200
- References
- 25
- FWCI
- 14.96
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.