Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 283

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.

Corneal Hysteresis as a Risk Factor for Glaucoma Progression: A Prospective Longitudinal Study

Open access
Medeiros, Felipe A., Meira-Freitas, Daniel, Lisboa, Renato, Kuang, Tung-Mei, Zangwill, Linda M., Weinreb, Robert N.·2013·Ophthalmology

Abstract

Purpose To evaluate the role of corneal hysteresis (CH) as a risk factor for the rate of visual field progression in a cohort of glaucoma patients followed prospectively over time. Design Prospective observational cohort study. Participants The study group included 114 eyes of 68 glaucoma patients followed for an average of 4.0 ± 1.1 years. Visual fields were obtained with standard automated perimetry. Included eyes had a median number of 7 (range: 5 to 12) tests during follow-up. Methods CH measurements were acquired at baseline using the Ocular Response Analyzer (Reichert Instruments, Depew, NY, USA). Evaluation of rates of visual field change during follow-up was performed using the Visual Field Index (VFI). Linear mixed models were used to investigate the relationship between rates of visual field loss and baseline CH, baseline intraocular pressure (IOP) and central corneal thickness (CCT), while adjusting for potentially confounding factors. An interaction term between IOP and CH was included in the model to investigate whether the effect of IOP on rates of progression depended on the level of CH. Main Outcome Measures Effects of CH, IOP and CCT on rates of VFI loss over time. Results CH had a significant effect on rates of visual field progression over time. In the univariable model including only CH as a predictive factor along with time and their interaction, each 1mmHg lower CH was associated with 0.25%/year faster rate of VFI decline over time (P<0.001). The multivariable model showed that the effect of IOP on rates of progression depended on CH. Eyes with high IOP and low CH were at increased risk for having fast rates of disease progression. CH explained a larger proportion of the variation in slopes of VFI change than CCT (17.4% versus 5.2%, respectively). Conclusion CH measurements were significantly associated with risk of glaucoma progression. Eyes with lower CH had faster rates of visual field loss than those with higher CH. The prospective longitudinal design of this study supports the role of CH as an important factor to be considered in the assessment of the risk of progression in glaucoma patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ophtha.2013.01.032

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 33 references

Cited by

See all 283

Metadata

Authors
Medeiros, F. A., Meira-Freitas, D., Lisboa, R., Kuang, T.-M., Zangwill, L. M., & Weinreb, R. N.
Venue
Ophthalmology
Publisher
Elsevier BV
Published
2013-08
Volume
120
Issue
8
Pages
1533-1540
ISSN
0161-6420 (ISSN-L)
OpenAlex
W2070829567
Cited by
283
References
33
FWCI
13.55
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Corneal Hysteresis as a Risk Factor for Glaucoma Progression: A Prospective Longitudinal Study. https://app.cochat.ai/papers/10.1016/j.ophtha.2013.01.032
The paper
Medeiros, F. A., Meira-Freitas, D., Lisboa, R., Kuang, T.-M., Zangwill, L. M., & Weinreb, R. N. (2013). Corneal Hysteresis as a Risk Factor for Glaucoma Progression: A Prospective Longitudinal Study. Ophthalmology. https://doi.org/10.1016/j.ophtha.2013.01.032

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.