Assessing Viral Shedding and Infectivity of Tears in Coronavirus Disease 2019 (COVID-19) Patients

Open access
Seah, Ivan Yu Jun, Anderson, Danielle E., Kang, Adrian Eng Zheng, Wang, Linfa, Rao, Pooja, Young, Barnaby Edward, Lye, David Chien, Agrawal, Rupesh·2020·Ophthalmology

Abstract

Severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) has spread rapidly across the globe to cause a pandemic. Although it is known to be transmitted via droplets, alternative modes of transmission remain unknown. Transmission through infected ocular tissue or fluid has been a controversy. It is hypothesized that the nasolacrimal system can act as a conduit for viruses to travel from the upper respiratory tract to the eye. Hence, ocular tissue and fluid may represent a potential source of SARS-CoV2. In this study, we attempted to determine the possibility of transmission through tears by assessing for the presence of SARSCoV-2 with viral isolation and quantitative reverse-transcription polymerase chain reaction (RT-PCR) analysis. As patients were being monitored clinically via routine nasopharyngeal swabs, these results were compared with those of tears to understand further patterns of viral shedding. Seventeen coronavirus disease 2019 (COVID-19) patients were recruited for this prospective study in Singapore after obtaining informed consent. This study was carried out in accordance with the tenets of the Declaration of Helsinki and with ethics approval from the Domain Specific Review Board of the National Healthcare Group Singapore. Nasopharyngeal swab samples were collected routinely for clinical monitoring of patient conditions, whereas tear samples were collected purely for research purposes. On some days, both tears and nasopharyngeal swab samples were collected at the same time. These samples were delivered to different labs for processing. The COVID-19 patients showed positive results by RT-PCR of nasopharyngeal swab samples in a clinical diagnostic laboratory. Nasopharyngeal swab samples were collected in universal viral transport media, and RNA extraction was carried out using the NucliSENS easyMAG system (bioMérieux, Marcy l’Etoile, France). Then, using the A*STAR Fortitude kit (Accelerate Technologies Pte. Ltd., Singapore, Republic of Singapore), 55 ml of the elute was used to perform RT-PCR analysis according to the manufacturer’s instructions. The limit of detection was estimated to be fewer than 25 copies of RNA. Tears were sampled by a senior consultant ophthalmologist (R.A.) using a Schirmer test strip at varying time points between days 3 and 20 after the initial development of symptoms. Caution was taken to prevent contamination of samples. The Schirmer strip tear collection method was validated previously in other studies. Samples from both eyes were obtained and analyzed separately. Collected strips were placed into individual falcon tubes of universal viral transport media. Samples were delivered to a research laboratory for processing. Samples were used to inoculate Vero-E6 cells (American Type Culture Collection [ATCC] CRL1586TM). After 4 days of incubation, cells were observed for the presence of cytopathic effect. Total RNA was extracted from all samples using E.Z.N.A. Total RNA Kit I (Omega Bio-Tek, Inc, Norcross, GA) according to the manufacturer’s instructions, and samples were analyzed by real-time quantitative RT-PCR for the detection of SARS-CoV-2 as described previously. Clinical data, including age, gender, symptoms, and nasopharyngeal swab results, were collected from electronic health records and were correlated with RT-PCR results. Ocular symptoms that were assessed include red eye, tearing, blurring of vision, discharge, and color desaturation. These symptoms were chosen based on the ocular manifestations of other coronaviruses known to infect humans and animals. Other symptoms of COVID-19 assessed included fever, cough, shortness of breath, rhinorrhea, and sore throat. Of the 17 patients recruited, none demonstrated ocular symptoms. However, 1 patient developed conjunctival injection and chemosis during the stay in the hospital (Table S1, available at www.aaojournal.org). Fourteen patients showed upper respiratory tract symptoms at presentation, including cough, rhinorrhea, and sore throat. A total of 64 samples were obtained over the study period, with 12, 28, and 24 samples obtained from the first, second, and third week of initial symptoms, respectively. All samples showed negative results for SARS-CoV-2 on viral isolation and RT-PCR. Tear results were compared with nasopharyngeal swab sample results, as shown in Figure 1. Cycle threshold values of nasopharyngeal swab samples were featured. In this study, viral shedding in tears was compared with nasopharyngeal swab sample results during the course of COVID-19 infection. A previous study showed positive SARS-CoV-2 RTPCR results from a patient’s tears, but isolation of the virus was unsuccessful. In this study, no evidence was found of SARS-CoV-2 shedding in tears through the course of the disease. Viral load detected in nasal and throat swabs have been shown to be elevated for a period of approximately 2 weeks from the onset of COVID-19 symptoms. In this study, the tear sampling time points cover these 2 weeks of active infection, providing a good representation of the full disease course. All tear samples showed negative results, even when nasopharyngeal swab samples continued to show positive results. Furthermore, patients with symptoms of upper respiratory tract infections did not demonstrate any viral shedding in tears, suggesting that the hypothesis of the lacrimal duct as a viral conduit may not be true. Most importantly, only 1 patient showed ocular symptoms during the disease course, and no evidence of SARS-CoV-2 could be found in the tear samples. This suggests that transmission through tears regardless of the phase of infection likely is low. The study had several limitations. First, the samples were analyzed in different laboratories using 2 different assays. Because the nasopharyngeal swab samples were used in the clinical setting to monitor disease progression, they were analyzed in a clinical diagnostics laboratory, whereas the tear samples were analyzed in a research laboratory. Although the limit of detection for the research laboratory was not assessed because of logistical limitations, it should be noted that the tear samples were incubated with Vero-E6

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ophtha.2020.03.026

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 401

Metadata

Authors
Seah, I. Y. J., Anderson, D. E., Kang, A. E. Z., Wang, L., Rao, P., Young, B. E., Lye, D. C., & Agrawal, R.
Venue
Ophthalmology
Publisher
Elsevier BV
Published
2020-07
Volume
127
Issue
7
Pages
977-979
ISSN
0161-6420 (ISSN-L)
OpenAlex
W3013245109
Cited by
401
References
1
FWCI
64.98
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessing Viral Shedding and Infectivity of Tears in Coronavirus Disease 2019 (COVID-19) Patients. https://app.cochat.ai/papers/10.1016/j.ophtha.2020.03.026
The paper
Seah, I. Y. J., Anderson, D. E., Kang, A. E. Z., Wang, L., Rao, P., Young, B. E., Lye, D. C., & Agrawal, R. (2020). Assessing Viral Shedding and Infectivity of Tears in Coronavirus Disease 2019 (COVID-19) Patients. Ophthalmology. https://doi.org/10.1016/j.ophtha.2020.03.026

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.