The DOI matches its Crossref record; 91 of the 91 references it cites were found in a registry or an index.
Sensitivity of photoacoustic microscopy
Open accessAbstract
Building on its high spatial resolution, deep penetration depth and excellent image contrast, 3D photoacoustic microscopy (PAM) has grown tremendously since its first publication in 2005. Integrating optical excitation and acoustic detection, PAM has broken through both the optical diffusion and optical diffraction limits. PAM has 100% relative sensitivity to optical absorption (i.e., a given percentage change in the optical absorption coefficient yields the same percentage change in the photoacoustic amplitude), and its ultimate detection sensitivity is limited only by thermal noise. Focusing on the engineering aspects of PAM, this Review discusses the detection sensitivity of PAM, compares the detection efficiency of different PAM designs, and summarizes the imaging performance of various endogenous and exogenous contrast agents. It then describes representative PAM applications with high detection sensitivity, and outlines paths to further improvement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hallmarks of Cancer: The Next Generation
Hanahan, D., & Weinberg, R. A. (2011) · Cell · doi:10.1016/j.cell.2011.02.013 · Cited by 66,590
Photoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331
Self-citationBiomedical photoacoustic imaging
Beard, P. (2011) · Interface Focus · doi:10.1098/rsfs.2011.0028 · Cited by 2,205
Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging
Zhang, H. F., Maslov, K., Stoica, G., & Wang, L. V. (2006) · Nature Biotechnology · doi:10.1038/nbt1220 · Cited by 1,854
Self-citationMultiscale photoacoustic microscopy and computed tomography
Wang, L. V. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.157 · Cited by 1,400
Self-citationCarbon nanotubes as photoacoustic molecular imaging agents in living mice
De La Zerda, A., Zavaleta, C., Keren, S., Vaithilingam, S., Bodapati, S., Liu, Z., Levi, J., Smith, B. R., Ma, T.-J., Oralkan, O., et al. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.231 · Cited by 1,271
Universal back-projection algorithm for photoacoustic computed tomography
Xu, M., & Wang, L. V. (2005) · Physical Review E · doi:10.1103/physreve.71.016706 · Cited by 1,243
Self-citationBiomedical Optics, Principles and Imaging
Wang, L. V., Wu, H.-I., & Masters, B. R. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2976007 · Cited by 1,178
Self-citationKim, C., Favazza, C., & Wang, L. V. (2010) · Chemical Reviews · doi:10.1021/cr900266s · Cited by 807
Self-citationNew Technologies for Human Cancer Imaging
Frangioni, J. V. (2008) · Journal of Clinical Oncology · doi:10.1200/jco.2007.14.3065 · Cited by 800
Cited by
Tutorial on photoacoustic tomography
Zhou, Y., Yao, J., & Wang, L. V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.6.061007 · Cited by 421
Self-citationPhotoacoustic tomography of blood oxygenation: A mini review
Li, M., Tang, Y., & Yao, J. (2018) · Photoacoustics · doi:10.1016/j.pacs.2018.05.001 · Cited by 359
Self-citationPhotoacoustics: a historical review
Manohar, S., & Razansky, D. (2016) · Advances in Optics and Photonics · doi:10.1364/aop.8.000586 · Cited by 319
Metadata
- Authors
- Yao, J., & Wang, L. V.
- Venue
- Photoacoustics
- Publisher
- Elsevier BV
- Published
- 2014-06
- Volume
- 2
- Issue
- 2
- Pages
- 87-101
- ISSN
- 2213-5979 (ISSN-L)
- OpenAlex
- W1972504893
- Cited by
- 418
- References
- 91
- FWCI
- 14.73
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensitivity of photoacoustic microscopy. https://app.cochat.ai/papers/10.1016/j.pacs.2014.04.002
- The paper
- Yao, J., & Wang, L. V. (2014). Sensitivity of photoacoustic microscopy. Photoacoustics. https://doi.org/10.1016/j.pacs.2014.04.002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.