The DOI matches its Crossref record; 242 of the 242 references it cites were found in a registry or an index.
Quantum metrology and its application in biology
Open accessAbstract
Abstract Quantum metrology provides a route to overcome practical limits in sensing devices. It holds particular relevance to biology, where sensitivity and resolution constraints restrict applications both in fundamental biophysics and in medicine. Here, we review quantum metrology from this biological context, focusing on optical techniques due to their particular relevance for biological imaging, sensing, and stimulation. Our understanding of quantum mechanics has already enabled important applications in biology, including positron emission tomography (PET) with entangled photons, magnetic resonance imaging (MRI) using nuclear magnetic resonance, and bio-magnetic imaging with superconducting quantum interference devices (SQUIDs). In quantum metrology an even greater range of applications arise from the ability to not just understand, but to engineer, coherence and correlations at the quantum level. In the past few years, quite dramatic progress has been seen in applying these ideas into biological systems. Capabilities that have been demonstrated include enhanced sensitivity and resolution, immunity to imaging artefacts and technical noise, and characterization of the biological response to light at the single-photon level. New quantum measurement techniques offer even greater promise, raising the prospect for improved multi-photon microscopy and magnetic imaging, among many other possible applications. Realization of this potential will require cross-disciplinary input from researchers in both biology and quantum physics. In this review we seek to communicate the developments of quantum metrology in a way that is accessible to biologists and biophysicists, while providing sufficient details to allow the interested reader to obtain a solid understanding of the field. We further seek to introduce quantum physicists to some of the central challenges of optical measurements in biological science. We hope that this will aid in bridging the communication gap that exists between the fields, and thereby guide the future development of this multidisciplinary research area.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
On the Quantum Correction For Thermodynamic Equilibrium
Wigner, E. (1932) · Physical Review · doi:10.1103/physrev.40.749 · Cited by 9,283
Optical Coherence and Quantum Optics
Mandel, L., & Wolf, E. (1995) · doi:10.1017/cbo9781139644105 · Cited by 8,356
Coherent and Incoherent States of the Radiation Field
Glauber, R. J. (1963) · Physical Review · doi:10.1103/physrev.131.2766 · Cited by 6,797
A General Model for the Origin of Allometric Scaling Laws in Biology
West, G. B., Brown, J. H., & Enquist, B. J. (1997) · Science · doi:10.1126/science.276.5309.122 · Cited by 5,016
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Optical Constants of Water in the 200-nm to 200-μm Wavelength Region
Hale, G. M., & Querry, M. R. (1973) · Applied Optics · doi:10.1364/ao.12.000555 · Cited by 4,468
Measurement of subpicosecond time intervals between two photons by interference
Hong, C. K., Ou, Z. Y., & Mandel, L. (1987) · Physical Review Letters · doi:10.1103/physrevlett.59.2044 · Cited by 4,369
Deep tissue two-photon microscopy
Helmchen, F., & Denk, W. (2005) · Nature Methods · doi:10.1038/nmeth818 · Cited by 4,153
The Quantum Theory of Optical Coherence
Glauber, R. J. (1963) · Physical Review · doi:10.1103/physrev.130.2529 · Cited by 4,077
Cited by
Plasmonic Biosensing: Focus Review
Mejía-Salazar, J. R., & Oliveira, O. N. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00359 · Cited by 544
Cellpose3: one-click image restoration for improved cellular segmentation
Stringer, C., & Pachitariu, M. (2025) · Nature Methods · doi:10.1038/s41592-025-02595-5 · Cited by 461
Polino, E., Valeri, M., Spagnolo, N., & Sciarrino, F. (2020) · AVS Quantum Science · doi:10.1116/5.0007577 · Cited by 414
Imaging with quantum states of light
Moreau, P.-A., Toninelli, E., Gregory, T., & Padgett, M. J. (2019) · Nature Reviews Physics · doi:10.1038/s42254-019-0056-0 · Cited by 400
Quantum-enhanced nonlinear microscopy
Casacio, C. A., Madsen, L. S., Terrasson, A., Waleed, M., Barnscheidt, K., Hage, B., Taylor, M. A., & Bowen, W. P. (2021) · Nature · doi:10.1038/s41586-021-03528-w · Cited by 344
Self-citationOptimal adaptive control for quantum metrology with time-dependent Hamiltonians
Pang, S., & Jordan, A. N. (2017) · Nature Communications · doi:10.1038/ncomms14695 · Cited by 195
Experimental phase estimation enhanced by machine learning
Lumino, A., Polino, E., Rab, A. S., Milani, G., Spagnolo, N., Wiebe, N., & Sciarrino, F. (2018) · Physical Review Applied · doi:10.1103/physrevapplied.10.044033 · Cited by 97
Biology and medicine in the landscape of quantum advantages
Cordier, B. A., Sawaya, N. P. D., Guerreschi, G. G., & McWeeney, S. K. (2022) · Journal of The Royal Society Interface · doi:10.1098/rsif.2022.0541 · Cited by 87
Quantum plasmonic N00N state in a silver nanowire and its use for quantum sensing
Chen, Y., Lee, C., Lu, L., Liu, D., Wu, Y.-K., Feng, L.-T., Li, M., Rockstuhl, C., Guo, G.-P., Guo, G.-C., et al. (2018) · Optica · doi:10.1364/optica.5.001229 · Cited by 43
Metadata
- Authors
- Taylor, M. A., & Bowen, W. P.
- Venue
- Physics Reports
- Publisher
- Elsevier BV
- Published
- 2016-02
- Volume
- 615
- Pages
- 1-59
- ISSN
- 0370-1573 (ISSN-L)
- OpenAlex
- W1597866600
- Cited by
- 470
- References
- 242
- FWCI
- 20.65
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.