Pros and cons of ultra-high-field MRI/MRS for human application
Open accessThe DOI matches its Crossref record; 596 of the 599 references it cites were found in a registry or an index.
Abstract
Magnetic resonance imaging and spectroscopic techniques are widely used in humans both for clinical diagnostic applications and in basic research areas such as cognitive neuroimaging. In recent years, new human MR systems have become available operating at static magnetic fields of 7 T or higher (≥300 MHz proton frequency). Imaging human-sized objects at such high frequencies presents several challenges including non-uniform radiofrequency fields, enhanced susceptibility artifacts, and higher radiofrequency energy deposition in the tissue. On the other side of the scale are gains in signal-to-noise or contrast-to-noise ratio that allow finer structures to be visualized and smaller physiological effects to be detected. This review presents an overview of some of the latest methodological developments in human ultra-high field MRI/MRS as well as associated clinical and scientific applications. Emphasis is given to techniques that particularly benefit from the changing physical characteristics at high magnetic fields, including susceptibility-weighted imaging and phase-contrast techniques, imaging with X-nuclei, MR spectroscopy, CEST imaging, as well as functional MRI. In addition, more general methodological developments such as parallel transmission and motion correction will be discussed that are required to leverage the full potential of higher magnetic fields, and an overview of relevant physiological considerations of human high magnetic field exposure is provided.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These experimental errors also affect NMR and MRI at high and ultra-high magnetic fields as they require high-fidelity levels for coherent and high-efficiency control of heterogeneous spin ensembles (9, 10).”
From High-Fidelity Control of Spin Ensemble Dynamics via Artificial Intelligence: From Quantum Computing to Imaging (2021) · cites this paper as [9]
In the citing paper
“The latter shows that the algorithm has the potential to generate ultra low-power pulses for MRI, where power deposition becomes a problem for human subjects (9).”
From High-Fidelity Control of Spin Ensemble Dynamics via Artificial Intelligence: From Quantum Computing to Imaging (2021) · cites this paper as [9]
In the citing paper
“RF inhomogeneity represents a severe problem for MRI both at low and high magnetic fields, limiting both the resolution and sensitivity of images (9).”
From High-Fidelity Control of Spin Ensemble Dynamics via Artificial Intelligence: From Quantum Computing to Imaging (2021) · cites this paper as [9]
In the citing paper
“In theory, it is possible to generate ultra-BB pulses for a range of very large BWs (9).”
From High-Fidelity Control of Spin Ensemble Dynamics via Artificial Intelligence: From Quantum Computing to Imaging (2021) · cites this paper as [9]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Donoho, D. L. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.871582 · Cited by 23,994
Donoho, D. L. (2004) · Cited by 16,591
Candes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance
LAUTERBUR, P. C. (1973) · Nature · doi:10.1038/242190a0 · Cited by 3,611
Magnetic Resonance Imaging: Physical Principles and Sequence Design
Brown, R. W., Cheng, Y. N., Haacke, E. M., Thompson, M. R., & Venkatesan, R. (2014) · doi:10.1002/9781118633953 · Cited by 2,688
Roemer, P. B., Edelstein, W. A., Hayes, C. E., Souza, S. P., & Mueller, O. M. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160203 · Cited by 2,322
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Ogawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772
Cited by
A Novel Miniaturized mmWave Antenna Sensor for Breast Tumor Detection and 5G Communication
Das, C., Chowdhury, M. Z., & Jang, Y. M. (2022) · IEEE Access · doi:10.1109/access.2022.3216858 · Cited by 301
Simultaneous EEG-fMRI: What Have We Learned and What Does the Future Hold?
Warbrick, T. (2022) · Sensors · doi:10.3390/s22062262 · Cited by 207
Elsayed, M., Isah, A., Hiba, M., Hassan, A., Al-Garadi, K., Mahmoud, M., El-Husseiny, A., & Radwan, A. E. (2022) · Journal of Petroleum Exploration and Production Technology · doi:10.1007/s13202-022-01476-3 · Cited by 203
MRI-guided Radiation Therapy: An Emerging Paradigm in Adaptive Radiation Oncology
Otazo, R., Lambin, P., Pignol, J.-P., Ladd, M. E., Schlemmer, H.-P., Baumann, M., & Hricak, H. (2021) · Radiology · doi:10.1148/radiol.2020202747 · Cited by 168
Self-citationKamimura, H. A. S., Conti, A., Toschi, N., & Konofagou, E. E. (2020) · Frontiers in Physics · doi:10.3389/fphy.2020.00150 · Cited by 146
Metadata
- Authors
- Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M.
- Venue
- Progress in Nuclear Magnetic Resonance Spectroscopy
- Publisher
- Elsevier BV
- Published
- 2018-12
- Volume
- 109
- Pages
- 1-50
- ISSN
- 0079-6565 (ISSN-L)
- OpenAlex
- W2806074443
- Cited by
- 544
- References
- 599
- FWCI
- 27.40
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.