Spaide, Richard F., Gemmy Cheung, Chui Ming, Matsumoto, Hidetaka, Kishi, Shoji, Boon, Camiel J.F., van Dijk, Elon H.C., Mauget-Faysse, Martine, Behar-Cohen, Francine, Hartnett, M. Elizabeth, Sivaprasad, Sobha, Iida, Tomohiro, Brown, David M., Chhablani, Jay, Maloca, Peter M.·2022·Progress in Retinal and Eye Research

Abstract

In central serous chorioretinopathy (CSC), the macula is detached because of fluid leakage at the level of the retinal pigment epithelium. The fluid appears to originate from choroidal vascular hyperpermeability, but the etiology for the fluid is controversial. The choroidal vascular findings as elucidated by recent optical coherence tomography (OCT) and wide-field indocyanine green (ICG) angiographic evaluation show eyes with CSC have many of the same venous patterns that are found in eyes following occlusion of the vortex veins or carotid cavernous sinus fistulas (CCSF). The eyes show delayed choroidal filling, dilated veins, intervortex venous anastomoses, and choroidal vascular hyperpermeability. While patients with occlusion of the vortex veins or CCSF have extraocular abnormalities accounting for the venous outflow problems, eyes with CSC appear to have venous outflow abnormalities as an intrinsic phenomenon. Control of venous outflow from the eye involves a Starling resistor effect, which appears to be abnormal in CSC. Similar choroidal vascular abnormalities have been found in peripapillary pachychoroid syndrome. However, peripapillary pachychoroid syndrome has intervortex venous anastomoses located in the peripapillary region while in CSC these are seen to be located in the macular region. Spaceflight associated neuro-ocular syndrome appears to share many of the pathophysiologic problems of abnormal venous outflow from the choroid along with a host of associated abnormalities. These diseases vary according to their underlying etiologies but are linked by the venous decompensation in the choroid that leads to significant vision loss. Choroidal venous overload provides a unifying concept and theory for an improved understanding of the pathophysiology and classification of a group of diseases to a greater extent than previous proposals.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.preteyeres.2021.100973

Cites

94 of 94 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 94 references

Metadata

Authors
Spaide, R. F., Gemmy Cheung, C. M., Matsumoto, H., Kishi, S., Boon, C. J. F., van Dijk, E. H. C., Mauget-Faysse, M., Behar-Cohen, F., Hartnett, M. E., Sivaprasad, S., Iida, T., Brown, D. M., Chhablani, J., & Maloca, P. M.
Venue
Progress in Retinal and Eye Research
Publisher
Elsevier BV
Published
2022-01
Volume
86
Pages
100973
ISSN
1350-9462 (ISSN-L)
OpenAlex
W3164822084
Cited by
372
References
94
FWCI
40.97
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Venous overload choroidopathy: A hypothetical framework for central serous chorioretinopathy and allied disorders. https://app.cochat.ai/papers/10.1016/j.preteyeres.2021.100973
The paper
Spaide, R. F., Gemmy Cheung, C. M., Matsumoto, H., Kishi, S., Boon, C. J. F., van Dijk, E. H. C., Mauget-Faysse, M., Behar-Cohen, F., Hartnett, M. E., Sivaprasad, S., Iida, T., Brown, D. M., Chhablani, J., & Maloca, P. M. (2022). Venous overload choroidopathy: A hypothetical framework for central serous chorioretinopathy and allied disorders. Progress in Retinal and Eye Research. https://doi.org/10.1016/j.preteyeres.2021.100973

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.