Optical coherence tomography angiography in diabetic retinopathy
Open accessThe DOI matches its Crossref record; 108 of the 108 references it cites were found in a registry or an index.
Abstract
There remain many unanswered questions on how to assess and treat the pathology and complications that arise from diabetic retinopathy (DR). Optical coherence tomography angiography (OCTA) is a novel and non-invasive three-dimensional imaging method that can visualize capillaries in all retinal layers. Numerous studies have confirmed that OCTA can identify early evidence of microvascular changes and provide quantitative assessment of the extent of diseases such as DR and its complications. A number of informative OCTA metrics could be used to assess DR in clinical trials, including measurements of the foveal avascular zone (FAZ; area, acircularity, 3D para-FAZ vessel density), vessel density, extrafoveal avascular zones, and neovascularization. Assessing patients with DR using a full-retinal slab OCTA image can limit segmentation errors and confounding factors such as those related to center-involved diabetic macular edema. Given emerging data suggesting the importance of the peripheral retinal vasculature in assessing and predicting DR progression, wide-field OCTA imaging should also be used. Finally, the use of automated methods and algorithms for OCTA image analysis, such as those that can distinguish between areas of true and false signals, reconstruct images, and produce quantitative metrics, such as FAZ area, will greatly improve the efficiency and standardization of results between studies. Most importantly, clinical trial protocols should account for the relatively high frequency of poor-quality data related to sub-optimal imaging conditions in DR and should incorporate time for assessing OCTA image quality and re-imaging patients where necessary.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Global Prevalence of Diabetic Retinopathy and Projection of Burden through 2045
Teo, Z. L., Tham, Y.-C., Yu, M., Chee, M. L., Rim, T. H., Cheung, N., Bikbov, M. M., Wang, Y. X., Tang, Y., Lu, Y., et al. (2021) · Ophthalmology · doi:10.1016/j.ophtha.2021.04.027 · Cited by 2,420
(1991) · Ophthalmology · doi:10.1016/s0161-6420(13)38012-9 · Cited by 2,048
Optical coherence tomography angiography
Spaide, R. F., Fujimoto, J. G., Waheed, N. K., Sadda, S. R., & Staurenghi, G. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.11.003 · Cited by 1,779
Self-citationEpidemiology of diabetic retinopathy, diabetic macular edema and related vision loss
Lee, R., Wong, T. Y., & Sabanayagam, C. (2015) · Eye and Vision · doi:10.1186/s40662-015-0026-2 · Cited by 1,569
A review of optical coherence tomography angiography (OCTA)
de Carlo, T. E., Romano, A., Waheed, N. K., & Duker, J. S. (2015) · International Journal of Retina and Vitreous · doi:10.1186/s40942-015-0005-8 · Cited by 1,126
Self-citationKashani, A. H., Chen, C.-L., Gahm, J. K., Zheng, F., Richter, G. M., Rosenfeld, P. J., Shi, Y., & Wang, R. K. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.07.002 · Cited by 1,006
Diabetic Retinopathy: A Position Statement by the American Diabetes Association
Solomon, S. D., Chew, E., Duh, E. J., Sobrin, L., Sun, J. K., VanderBeek, B. L., Wykoff, C. C., & Gardner, T. W. (2017) · Diabetes Care · doi:10.2337/dc16-2641 · Cited by 940
Jia, Y., Bailey, S. T., Hwang, T. S., McClintic, S. M., Gao, S. S., Pennesi, M. E., Flaxel, C. J., Lauer, A. K., Wilson, D. J., Hornegger, J., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1500185112 · Cited by 665
Self-citationOptical Coherence Tomography Angiography in Diabetic Retinopathy: A Prospective Pilot Study
Ishibazawa, A., Nagaoka, T., Takahashi, A., Omae, T., Tani, T., Sogawa, K., Yokota, H., & Yoshida, A. (2015) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2015.04.021 · Cited by 617
Cited by
Tao, Y., Xiong, M., Peng, Y., Yao, L., Zhu, H., Zhou, Q., & Ouyang, J. (2025) · Gene · doi:10.1016/j.gene.2024.149015 · Cited by 16
Kumar, R., Gowda, C., Sekhar, T., Vaja, S., Hage, T., Sporn, K., Waisberg, E., Ong, J., Zaman, N., & Tavakkoli, A. (2025) · doi:10.20944/preprints202504.2430.v1 · Cited by 10
Metadata
- Authors
- Waheed, N. K., Rosen, R. B., Jia, Y., Munk, M. R., Huang, D., Fawzi, A., Chong, V., Nguyen, Q. D., Sepah, Y., & Pearce, E.
- Venue
- Progress in Retinal and Eye Research
- Publisher
- Elsevier BV
- Published
- 2023-11
- Volume
- 97
- Pages
- 101206
- ISSN
- 1350-9462 (ISSN-L)
- OpenAlex
- W4385321423
- Cited by
- 179
- References
- 108
- FWCI
- 36.69
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical coherence tomography angiography in diabetic retinopathy. https://app.cochat.ai/papers/10.1016/j.preteyeres.2023.101206
- The paper
- Waheed, N. K., Rosen, R. B., Jia, Y., Munk, M. R., Huang, D., Fawzi, A., Chong, V., Nguyen, Q. D., Sepah, Y., & Pearce, E. (2023). Optical coherence tomography angiography in diabetic retinopathy. Progress in Retinal and Eye Research. https://doi.org/10.1016/j.preteyeres.2023.101206
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.