The DOI matches its Crossref record; 90 of the 90 references it cites were found in a registry or an index.
Use of PET and PET/CT for Radiation Therapy Planning: IAEA expert report 2006–2007
Open accessAbstract
Positron Emission Tomography (PET) is a significant advance in cancer imaging with great potential for optimizing radiation therapy (RT) treatment planning and thereby improving outcomes for patients. The use of PET and PET/CT in RT planning was reviewed by an international panel. The International Atomic Energy Agency (IAEA) organized two synchronized and overlapping consultants' meetings with experts from different regions of the world in Vienna in July 2006. Nine experts and three IAEA staff evaluated the available data on the use of PET in RT planning, and considered practical methods for integrating it into routine practice. For RT planning, (18)F fluorodeoxyglucose (FDG) was the most valuable pharmaceutical. Numerous studies supported the routine use of FDG-PET for RT target volume determination in non-small cell lung cancer (NSCLC). There was also evidence for utility of PET in head and neck cancers, lymphoma and in esophageal cancers, with promising preliminary data in many other cancers. The best available approach employs integrated PET/CT images, acquired on a dual scanner in the radiotherapy treatment position after administration of tracer according to a standardized protocol, with careful optimization of images within the RT planning system and carefully considered rules for contouring tumor volumes. PET scans that are not recent or were acquired without proper patient positioning should be repeated for RT planning. PET will play an increasing valuable role in RT planning for a wide range of cancers. When requesting PET scans, physicians should be aware of their potential role in RT planning.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lardinois, D., Weder, W., Hany, T. F., Kamel, E. M., Korom, S., Seifert, B., von Schulthess, G. K., & Steinert, H. C. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022136 · Cited by 1,416
(1992) · PubMed Central · doi:10.2967/jnumed.120.251744a · Cited by 1,172
(2001) · PubMed · Cited by 943
Towards multidimensional radiotherapy (MD-CRT): biological imaging and biological conformality
Ling, C. C., Humm, J., Larson, S., Amols, H., Fuks, Z., Leibel, S., & Koutcher, J. A. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)00467-3 · Cited by 926
Gallamini, A., Hutchings, M., Rigacci, L., Specht, L., Merli, F., Hansen, M., Patti, C., Loft, A., Di Raimondo, F., D'Amore, F., et al. (2007) · Journal of Clinical Oncology · doi:10.1200/jco.2007.11.6525 · Cited by 846
Daisne, J.-F., Duprez, T., Weynand, B., Lonneux, M., Hamoir, M., Reychler, H., & Grégoire, V. (2004) · Radiology · doi:10.1148/radiol.2331030660 · Cited by 677
Dwamena, B. A., Sonnad, S. S., Angobaldo, J. O., & Wahl, R. L. (1999) · Radiology · doi:10.1148/radiology.213.2.r99nv46530 · Cited by 649
(2005) · PubMed · Cited by 612
Rasey, J. S., Koh, W.-J., Evans, M. L., Peterson, L. M., Lewellen, T. K., Graham, M. M., & Krohn, K. A. (1996) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(96)00325-2 · Cited by 562
Impact of FDG-PET on radiation therapy volume delineation in non–small-cell lung cancer
Bradley, J., Thorstad, W. L., Mutic, S., Miller, T. R., Dehdashti, F., Siegel, B. A., Bosch, W., & Bertrand, R. J. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2003.10.044 · Cited by 556
Ciernik, I. F., Dizendorf, E., Baumert, B. G., Reiner, B., Burger, C., Davis, J. B., Lütolf, U. M., Steinert, H. C., & Von Schulthess, G. K. (2003) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(03)00346-8 · Cited by 543
Rischin, D., Hicks, R. J., Fisher, R., Binns, D., Corry, J., Porceddu, S., & Peters, L. J. (2006) · Journal of Clinical Oncology · doi:10.1200/jco.2005.05.2878 · Cited by 541
Haioun, C., Itti, E., Rahmouni, A., Brice, P., Rain, J.-D., Belhadj, K., Gaulard, P., Garderet, L., Lepage, E., Reyes, F., et al. (2005) · Blood · doi:10.1182/blood-2005-01-0272 · Cited by 494
Segmentation of lung lesion volume by adaptive positron emission tomography image thresholding
Erdi, Y. E., Mawlawi, O., Larson, S. M., Imbriaco, M., Yeung, H., Finn, R., & Humm, J. L. (1997) · Cancer · doi:10.1002/(sici)1097-0142(19971215)80:12+<2505::aid-cncr24>3.0.co;2-f · Cited by 480
Eschmann, S. M., Paulsen, F., Reimold, M., Dittmann, H., Welz, S., Reischl, G., Machulla, H.-J., & Bares, R. (2005) · PubMed · Cited by 454
Bradley, J., Graham, M. V., Winter, K., Purdy, J. A., Komaki, R., Roa, W. H., Ryu, J. K., Bosch, W., & Emami, B. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.06.260 · Cited by 441
Mac Manus, M. P., Hicks, R. J., Matthews, J. P., McKenzie, A., Rischin, D., Salminen, E. K., & Ball, D. L. (2003) · Journal of Clinical Oncology · doi:10.1200/jco.2003.07.054 · Cited by 439
Self-citationImaging proliferation in brain tumors with 18F-FLT PET: comparison with 18F-FDG.
Chen, W., Cloughesy, T. F., Kamdar, N. V., Satyamurthy, N., Bergsneider, M., Liau, L. M., Mischel, P. S., Czernin, J., Phelps, M. E., & Silverman, D. H. S. (2005) · PubMed · Cited by 437
Chao, K. S. C., Bosch, W. R., Mutic, S., Lewis, J. S., Dehdashti, F., Mintun, M. A., Dempsey, J. F., Perez, C. A., Purdy, J. A., & Welch, M. J. (2001) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)01433-4 · Cited by 429
A gradient-based method for segmenting FDG-PET images: methodology and validation
Geets, X., Lee, J. A., Bol, A., Lonneux, M., & Grégoire, V. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-006-0363-4 · Cited by 419
Mikhaeel, N. G., Hutchings, M., Fields, P. A., O'Doherty, M. J., & Timothy, A. R. (2005) · Annals of Oncology · doi:10.1093/annonc/mdi272 · Cited by 401
Daisne, J.-F., Sibomana, M., Bol, A., Doumont, T., Lonneux, M., & Grégoire, V. (2003) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(03)00270-6 · Cited by 380
van Westreenen, H. L., Westerterp, M., Bossuyt, P. M. M., Pruim, J., Sloof, G. W., van Lanschot, J. J. B., Groen, H., & Plukker, J. T. M. (2004) · Journal of Clinical Oncology · doi:10.1200/jco.2004.01.083 · Cited by 370
In vivo assessment of tumor hypoxia in lung cancer with 60Cu-ATSM
Dehdashti, F., Mintun, M. A., Lewis, J. S., Bradley, J., Govindan, R., Laforest, R., Welch, M. J., & Siegel, B. A. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-003-1130-4 · Cited by 368
Reske, S. N., & Kotzerke, J. (2001) · European Journal of Nuclear Medicine · doi:10.1007/s002590100626 · Cited by 365
Nestle, U., Walter, K., Schmidt, S., Licht, N. P., Nieder, C., Motaref, B., Hellwig, D., Niewald, M., Ukena, D., Kirsch, C. M., et al. (1999) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(99)00061-9 · Cited by 353
Self-citationErdi, Y. E., Rosenzweig, K., Erdi, A. K., Macapinlac, H. A., Hu, Y.-C., Braban, L. E., Humm, J. L., Squire, O. D., Chui, C.-S., Larson, S. M., et al. (2002) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(01)00470-4 · Cited by 338
Self-citationPrognostic value of interim FDG-PET after two or three cycles of chemotherapy in Hodgkin lymphoma
Hutchings, M., Mikhaeel, N. G., Fields, P. A., Nunan, T., & Timothy, A. R. (2005) · Annals of Oncology · doi:10.1093/annonc/mdi200 · Cited by 327
Caldwell, C. B., Mah, K., Ung, Y. C., Danjoux, C. E., Balogh, J. M., Ganguli, S. N., & Ehrlich, L. E. (2001) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(01)01722-9 · Cited by 320
O-(2-[18F]fluoroethyl)-l-tyrosine: uptake mechanisms and clinical applications
Langen, K.-J., Hamacher, K., Weckesser, M., Floeth, F., Stoffels, G., Bauer, D., Coenen, H. H., & Pauleit, D. (2006) · Nuclear Medicine and Biology · doi:10.1016/j.nucmedbio.2006.01.002 · Cited by 316
Mah, K., Caldwell, C. B., Ung, Y. C., Danjoux, C. E., Balogh, J. M., Ganguli, S. N., Ehrlich, L. E., & Tirona, R. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(01)01824-7 · Cited by 307
van Baardwijk, A., Bosmans, G., Boersma, L., Buijsen, J., Wanders, S., Hochstenbag, M., van Suylen, R.-J., Dekker, A., Dehing-Oberije, C., Houben, R., et al. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.12.067 · Cited by 295
Westerterp, M., Pruim, J., Oyen, W., Hoekstra, O., Paans, A., Visser, E., van Lanschot, J., Sloof, G., & Boellaard, R. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-006-0224-1 · Cited by 294
Koh, W.-J., Bergman, K. S., Rasey, J. S., Peterson, L. M., Evans, M. L., Graham, M. M., Grierson, J. R., Lindsley, K. L., Lewellen, T. K., Krohn, K. A., et al. (1995) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(95)00170-4 · Cited by 288
Vanuytsel, L., Vansteenkiste, J., Stroobants, S. G., Leyn, P. R. D., Wever, W. D., Verbeken, E. K., Gatti, G. G., Huyskens, D. P., & Kutcher, G. J. (2000) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(00)00138-9 · Cited by 286
Detection of lung tumor movement in real-time tumor-tracking radiotherapy
Shimizu, S., Shirato, H., Ogura, S., Akita-Dosaka, H., Kitamura, K., Nishioka, T., Kagei, K., Nishimura, M., & Miyasaka, K. (2001) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(01)01641-8 · Cited by 270
Paulino, A. C., Koshy, M., Howell, R., Schuster, D., & Davis, L. W. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.08.037 · Cited by 264
Defining a radiotherapy target with positron emission tomography
Black, Q. C., Grills, I. S., Kestin, L. L., Wong, C.-Y. O., Wong, J. W., Martinez, A. A., & Yan, D. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.06.254 · Cited by 263
From tumor biology to clinical PET: A review of positron emission tomography (PET) in oncology
Kubota, K. (2001) · Annals of Nuclear Medicine · doi:10.1007/bf02988499 · Cited by 258
Definition of gross tumor volume in lung cancer: inter-observer variability
Van de Steene, J., Linthout, N., de Mey, J., Vinh-Hung, V., Claassens, C., Noppen, M., Bel, A., & Storme, G. (2002) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(01)00453-4 · Cited by 255
Imaging prostate cancer with 11C-choline PET/CT.
Reske, S. N., Blumstein, N. M., Neumaier, B., Gottfried, H., Finsterbusch, F., Kocot, D., Möller, P., Glatting, G., & Perner, S. (2006) · PubMed · Cited by 250
Grosu, A., Weber, W., Riedel, E., et al. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2005.01.045 · Cited by 242
Variability of gross tumor volume delineation in head-and-neck cancer using CT and PET/CT fusion
Riegel, A. C., Berson, A. M., Destian, S., Ng, T., Tena, L. B., Mitnick, R. J., & Wong, P. S. (2006) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.01.014 · Cited by 242
Defining a radiotherapy target with positron emission tomography
Black, Q. C., Yan, D., Kestin, L. L., Wong, C. O., Wong, J. W., & Martinez, A. A. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)03114-0 · Cited by 240
Ashamalla, H., Rafla, S., Parikh, K., Mokhtar, B., Goswami, G., Kambam, S., Abdel-Dayem, H., Guirguis, A., Ross, P., & Evola, A. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2005.04.021 · Cited by 239
Quantitation of respiratory motion during 4D‐PET/CT acquisition
Nehmeh, S. A., Erdi, Y. E., Pan, T., Yorke, E., Mageras, G. S., Rosenzweig, K. E., Schoder, H., Mostafavi, H., Squire, O., Pevsner, A., et al. (2004) · Medical Physics · doi:10.1118/1.1739671 · Cited by 232
Self-citationVansteenkiste, J., Fischer, B. M., Dooms, C., & Mortensen, J. (2004) · The Lancet Oncology · doi:10.1016/s1470-2045(04)01564-5 · Cited by 231
FDG-PET/CT imaging for preradiotherapy staging of head-and-neck squamous cell carcinoma
Schwartz, D. L., Ford, E., Rajendran, J., Yueh, B., Coltrera, M. D., Virgin, J., Anzai, Y., Haynor, D., Lewellyn, B., Mattes, D., et al. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.03.040 · Cited by 220
De Ruysscher, D., Wanders, S., van Haren, E., Hochstenbag, M., Geeraedts, W., Utama, I., Simons, J., Dohmen, J., Rhami, A., Buell, U., et al. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.12.019 · Cited by 214
Choi, J. Y., Lee, K. H., Shim, Y. M., Lee, K. S., Kim, J. J., Kim, S. E., & Kim, B. (2000) · PubMed · Cited by 204
Ryu, J.-S., Choi, N. C., Fischman, A. J., Lynch, T. J., & Mathisen, D. J. (2002) · Lung Cancer · doi:10.1016/s0169-5002(01)00332-4 · Cited by 200
Heinisch, M., Dirisamer, A., Loidl, W., Stoiber, F., Gruy, B., Haim, S., & Langsteger, W. (2006) · Molecular Imaging and Biology · doi:10.1007/s11307-005-0023-2 · Cited by 191
Seute, T., Leffers, P., ten Velde, G. P. M., & Twijnstra, A. (2008) · Cancer · doi:10.1002/cncr.23361 · Cited by 188
Kiffer, J. D., Berlangieri, S. U., Scott, A. M., Quong, G., Feigen, M., Schumer, W., Clarke, C. P., Knight, S. R., & Daniel, F. J. (1998) · Lung Cancer · doi:10.1016/s0169-5002(97)00086-x · Cited by 187
Schöder, H. M., Larson, S. M., & YEUNG, H. W. D. (2004) · PubMed · Cited by 182
FDG-PET in radiotherapy treatment planning: Pandora's box?
Paulino, A. C., & Johnstone, P. A. S. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2003.10.045 · Cited by 176
Munley, M. T., Marks, L. B., Scarfone, C., Sibley, G. S., Patz, E. F., Turkington, T. G., Jaszczak, R. J., Gilland, D. R., Anscher, M. S., & Coleman, R. E. (1999) · Lung Cancer · doi:10.1016/s0169-5002(99)00005-7 · Cited by 171
Caldwell, C. B., Mah, K., Skinner, M., & Danjoux, C. E. (2003) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)04609-6 · Cited by 171
Scarfone, C., Lavely, W. C., Cmelak, A. J., Delbeke, D., Martin, W. H., Billheimer, D. D., & Hallahan, D. E. (2004) · PubMed · Cited by 170
Thorwarth, D., Eschmann, S.-M., Scheiderbauer, J., Paulsen, F., & Alber, M. (2005) · BMC Cancer · doi:10.1186/1471-2407-5-152 · Cited by 169
van der Wel, A. M., Nijsten, S. M. J. J. G., Hochstenbag, M. M. H., Lamers, R. J. S., Boersma, L. J., Wanders, R., Lutgens, L. C. H. W., Zimny, M., Bentzen, S. M., Wouters, B. G., et al. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.06.205 · Cited by 165
A kinetic model for dynamic [18F]-Fmiso PET data to analyse tumour hypoxia
Thorwarth, D., Eschmann, S. M., Paulsen, F., & Alber, M. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/10/002 · Cited by 164
Manus, M. M., Hicks, R., Matthews, J., Wirth, A., Rischin, D., & Ball, D. (2005) · Lung Cancer · doi:10.1016/j.lungcan.2004.11.024 · Cited by 164
Hicks, R. J., Mac Manus, M. P., Matthews, J. P., Hogg, A., Binns, D., Rischin, D., Ball, D. L., & Peters, L. J. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.03.036 · Cited by 164
Self-citationImaging hypoxia and angiogenesis in tumors
Rajendran, J. G., & Krohn, K. A. (2005) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2004.08.004 · Cited by 152
Hellwig, D., Ukena, D., Paulsen, F., BAMBERG, M., & Kirsch, C. M. (2001) · Pneumologie · doi:10.1055/s-2001-16201 · Cited by 147
Breen, S. L., Publicover, J., Silva, S. D., et al. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.12.039 · Cited by 137
A review of the literature for whole-body FDG PET in the management of patients with melanoma.
Schwimmer, J., Essner, R., Patel, A., Jahan, S., Shepherd, J. E., Park, K., Phelps, M. E., Czernin, J., & Gambhir, S. S. (2000) · PubMed · Cited by 125
FDG-PET imaging for the staging and follow-up of small cell lung cancer
Schumacher, T., Brink, I., Mix, M. D., Reinhardt, M. J., Herget, G. W., Digel, W., Henke, M., Moser, E., & Nitzsche, E. U. (2001) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590100474 · Cited by 125
Is there a role for FGD-PET in radiotherapy planning in esophageal carcinoma?
Hamming‐Vrieze, O., Haustermans, K. M., Wever, W. D., Lerut, A., Cutsem, E. V., Ectors, N., Hiele, M. I., & Flamen, P. (2004) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2004.10.001 · Cited by 125
Monitoring chemotherapy and radiotherapy of solid tumors
Weber, W., & Wieder, H. A. (2006) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-006-0133-3 · Cited by 124
Nestle, U., Schaefer-Schuler, A., Kremp, S., Gröschel, A., Hellwig, D., Rübe, C., & Kirsch, C. (2006) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-006-0252-x · Cited by 98
Self-citationMiles, K. A., Griffiths, M. R., & Keith, C. J. (2005) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-005-1932-7 · Cited by 94
Automated 3-dimensional registration of stand-alone (18)F-FDG whole-body PET with CT.
Slomka, P. J., Dey, D., Przetak, C., Aladl, U. E., & Baum, R. P. (2003) · PubMed · Cited by 93
Brianzoni, E., Rossi, G., Ancidei, S., Berbellini, A., Capoccetti, F., Cidda, C., D’Avenia, P., Fattori, S., Montini, G. C., Valentini, G., et al. (2005) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-005-1845-5 · Cited by 90
Diagnostic Evaluation of Malignant Head and Neck Cancer by F-18-FDG PET Compared to CT/MRI
Martino, E. D., Jänicke, S., Cremerius, U., Adam, G., Zimny, M., Reinartz, P., Büll, U., & Nowak, B. (1999) · Nuklearmedizin - NuclearMedicine · doi:10.1055/s-0038-1632228 · Cited by 88
Yoshida, S., Nakagomi, K., 後藤, 修., Futatsubashi, M., & Torizuka, T. (2005) · Urologia Internationalis · doi:10.1159/000083551 · Cited by 83
Inoue, T., Koyama, K., Oriuchi, N., Alyafei, S., Yuan, Z., Suzuki, H., Takeuchi, K., Tomaru, Y., Tomiyoshi, K., Aoki, J., et al. (2001) · Radiology · doi:10.1148/radiology.220.1.r01jl1654 · Cited by 81
Self-citationGeets, X., Daisne, J., Grégoire, V., Hamoir, M., & Lonneux, M. (2004) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2004.02.013 · Cited by 77
Positron emission tomography with [18F]FDG for therapy response monitoring in lymphoma patients
Spaepen, K., Stroobants, S. G., Verhoef, G. E. G., & Mortelmans, L. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-003-1166-5 · Cited by 74
Duong, C., Demitriou, H., Weih, L., Thompson, A., Williams, D., Thomas, R. J. S., & Hicks, R. (2006) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-005-0028-8 · Cited by 74
Marom, E. M., Aloia, T. A., Moore, M.-B., Hara, M., Herndon, J. E., Harpole, D. H., Goodman, P. C., & Patz, E. F. (2001) · Lung Cancer · doi:10.1016/s0169-5002(00)00250-6 · Cited by 69
Miyazawa, H., Arai, T., Iio, M., & Hara, T. (1993) · PubMed · Cited by 64
FDG-PET Determination of Metabolically Active Tumor Volume and Comparison with CT.
Zasadny, K., Kison, P. V., Francis, I., & Wahl, R. (1998) · Clinical Positron Imaging · doi:10.1016/s1095-0397(98)00007-7 · Cited by 58
FDG-PET in the clinical management of Hodgkin lymphoma
Hutchings, M., Eigtved, A., & Specht, L. (2004) · Critical Reviews in Oncology/Hematology · doi:10.1016/j.critrevonc.2004.05.007 · Cited by 55
Position of nuclear medicine modalities in the diagnostic workup of cancer patients: lung cancer.
Baum, R. P., Hellwig, D., & Mezzetti, M. (2004) · PubMed · Cited by 53
Lodge, M. A., Badawi, R. D., Gilbert, R., Dibos, P. E., & Line, B. R. (2006) · PubMed · Cited by 36
Use of FDG-PET to monitor response to chemotherapy and radiotherapy in patients with lymphomas
Mikhaeel, N. G. (2006) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-006-0132-4 · Cited by 35
Schmücking, M., Baum, R. P., Bonnet, R. B., Junker, K., & Müller, K.-M. (2005) · Der Pathologe · doi:10.1007/s00292-005-0758-1 · Cited by 21
Sahdev, A., & Reznek, R. H. (2009) · Springer eBooks · doi:10.1007/978-3-540-85689-4_30 · Cited by 10
Cited by
_, _. (2008) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2008.0021 · Cited by 735
Erlandsson, K., Buvat, I., Pretorius, P. H., Thomas, B. A., & Hutton, B. F. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/21/r119 · Cited by 733
Ettinger, D. S., Akerley, W., Bepler, G., Blum, M. G., Chang, A., Cheney, R. T., Chirieac, L. R., D'Amico, T. A., Demmy, T. L., Ganti, A. K. P., et al. (2010) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2010.0056 · Cited by 730
Goldstraw, P., Ball, D., Jett, J. R., Le Chevalier, T., Lim, E., Nicholson, A. G., & Shepherd, F. A. (2011) · The Lancet · doi:10.1016/s0140-6736(10)62101-0 · Cited by 711
A review on segmentation of positron emission tomography images
Foster, B., Bagci, U., Mansoor, A., Xu, Z., & Mollura, D. J. (2014) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2014.04.014 · Cited by 370
Metadata
- Authors
- MacManus, M., Nestle, U., Rosenzweig, K. E., Carrio, I., Messa, C., Belohlavek, O., Danna, M., Inoue, T., Deniaud-Alexandre, E., Schipani, S., Watanabe, N., Dondi, M., & Jeremic, B.
- Venue
- Radiotherapy and Oncology
- Publisher
- Elsevier BV
- Published
- 2009-04
- Volume
- 91
- Issue
- 1
- Pages
- 85-94
- ISSN
- 0167-8140 (ISSN-L)
- OpenAlex
- W2080386114
- Cited by
- 367
- References
- 90
- FWCI
- 23.65
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.