Metrics to evaluate the performance of auto-segmentation for radiation treatment planning: A critical review
Open accessThe DOI matches its Crossref record; 67 of the 67 references it cites were found in a registry or an index.
Abstract
Advances in artificial intelligence-based methods have led to the development and publication of numerous systems for auto-segmentation in radiotherapy. These systems have the potential to decrease contour variability, which has been associated with poor clinical outcomes and increased efficiency in the treatment planning workflow. However, there are no uniform standards for evaluating auto-segmentation platforms to assess their efficacy at meeting these goals. Here, we review the most frequently used evaluation techniques which include geometric overlap, dosimetric parameters, time spent contouring, and clinical rating scales. These data suggest that many of the most commonly used geometric indices, such as the Dice Similarity Coefficient, are not well correlated with clinically meaningful endpoints. As such, a multi-domain evaluation, including composite geometric and/or dosimetric metrics with physician-reported assessment, is necessary to gauge the clinical readiness of auto-segmentation for radiation treatment planning.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
I.—COMPUTING MACHINERY AND INTELLIGENCE
TURING, A. M. (1950) · Mind · doi:10.1093/mind/lix.236.433 · Cited by 10,290
Computing Machinery and Intelligence (1950)
Turing, A. (2004) · The Essential Turing · doi:10.1093/oso/9780198250791.003.0017 · Cited by 6,118
Metrics for evaluating 3D medical image segmentation: analysis, selection, and tool
Taha, A. A., & Hanbury, A. (2015) · BMC Medical Imaging · doi:10.1186/s12880-015-0068-x · Cited by 2,920
Warfield, S. K., Zou, K. H., & Wells, W. M. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.828354 · Cited by 2,335
Statistical validation of image segmentation quality based on a spatial overlap index1
Zou, K. H., Warfield, S. K., Bharatha, A., Tempany, C. M. C., Kaus, M. R., Haker, S. J., Wells, W. M., Jolesz, F. A., & Kikinis, R. (2004) · Academic Radiology · doi:10.1016/s1076-6332(03)00671-8 · Cited by 1,849
Peters, L. J., O'Sullivan, B., Giralt, J., Fitzgerald, T. J., Trotti, A., Bernier, J., Bourhis, J., Yuen, K., Fisher, R., & Rischin, D. (2010) · Journal of Clinical Oncology · doi:10.1200/jco.2009.27.4498 · Cited by 812
Kachnic, L. A., Winter, K., Myerson, R. J., Goodyear, M. D., Willins, J., Esthappan, J., Haddock, M. G., Rotman, M., Parikh, P. J., Safran, H., et al. (2013) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2012.09.023 · Cited by 621
Radiotherapy Dose–Volume Effects on Salivary Gland Function
Deasy, J. O., Moiseenko, V., Marks, L., Chao, K. S. C., Nam, J., & Eisbruch, A. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.06.090 · Cited by 590
Rohlfing, T., Brandt, R., Menzel, R., & Maurer, C. R. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.11.010 · Cited by 573
Cardenas, C. E., Yang, J., Anderson, B. M., Court, L. E., & Brock, K. B. (2019) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2019.02.001 · Cited by 407
Vision 20/20: Perspectives on automated image segmentation for radiotherapy
Sharp, G., Fritscher, K. D., Pekar, V., Peroni, M., Shusharina, N., Veeraraghavan, H., & Yang, J. (2014) · Medical Physics · doi:10.1118/1.4871620 · Cited by 375
Clinical evaluation of atlas and deep learning based automatic contouring for lung cancer
Lustberg, T., van Soest, J., Gooding, M., Peressutti, D., Aljabar, P., van der Stoep, J., van Elmpt, W., & Dekker, A. (2018) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2017.11.012 · Cited by 368
Nikolov, S., Blackwell, S., Zverovitch, A., Mendes, R., Livne, M., De Fauw, J., Patel, Y., Meyer, C., Askham, H., Romera-Paredes, B., et al. (2021) · Journal of Medical Internet Research · doi:10.2196/26151 · Cited by 366
Vandewinckele, L., Claessens, M., Dinkla, A., Brouwer, C., Crijns, W., Verellen, D., & van Elmpt, W. (2020) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2020.09.008 · Cited by 321
Ohri, N., Shen, X., Dicker, A. P., Doyle, L. A., Harrison, A. S., & Showalter, T. N. (2013) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djt001 · Cited by 317
Object matching algorithms using robust Hausdorff distance measures
Sim, D., Kwon, O., & Park, R. (1999) · IEEE Transactions on Image Processing · doi:10.1109/83.748897 · Cited by 285
Abrams, R. A., Winter, K. A., Regine, W. F., Safran, H., Hoffman, J. P., Lustig, R., Konski, A. A., Benson, A. B., Macdonald, J. S., Rich, T. A., et al. (2012) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2010.11.039 · Cited by 278
Nikolov, S., Blackwell, S., Zverovitch, A., Mendes, R. L., Livne, M., Fauw, J. D., Patel, Y., Meyer, C., Askham, H., Romera‐Paredes, B., et al. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1809.04430 · Cited by 235
Vaassen, F., Hazelaar, C., Vaniqui, A., Gooding, M., van der Heyden, B., Canters, R., & van Elmpt, W. (2020) · Physics and Imaging in Radiation Oncology · doi:10.1016/j.phro.2019.12.001 · Cited by 204
Hatt, M., Lee, J. A., Schmidtlein, C. R., Naqa, I. E., Caldwell, C., De Bernardi, E., Lu, W., Das, S., Geets, X., Gregoire, V., et al. (2017) · Medical Physics · doi:10.1002/mp.12124 · Cited by 198
Teguh, D. N., Levendag, P. C., Voet, P. W. J., Al-Mamgani, A., Han, X., Wolf, T. K., Hibbard, L. S., Nowak, P., Akhiat, H., Dirkx, M. L. P., et al. (2011) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2010.07.009 · Cited by 194
QA makes a clinical trial stronger: Evidence-based medicine in radiation therapy
Weber, D. C., Tomsej, M., Melidis, C., & Hurkmans, C. W. (2012) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2012.08.008 · Cited by 194
Lee, A. W., Ng, W. T., Pan, J. J., Chiang, C.-L., Poh, S. S., Choi, H. C., Ahn, Y. C., AlHussain, H., Corry, J., Grau, C., et al. (2019) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2019.06.2540 · Cited by 183
Marks, L. B., Adams, R. D., Pawlicki, T., Blumberg, A. L., Hoopes, D., Brundage, M. D., & Fraass, B. A. (2013) · Practical Radiation Oncology · doi:10.1016/j.prro.2012.11.010 · Cited by 178
La Macchia, M., Fellin, F., Amichetti, M., Cianchetti, M., Gianolini, S., Paola, V., Lomax, A. J., & Widesott, L. (2012) · Radiation Oncology · doi:10.1186/1748-717x-7-160 · Cited by 172
Pathmanathan, A. U., van As, N. J., Kerkmeijer, L. G. W., Christodouleas, J., Lawton, C. A. F., Vesprini, D., van der Heide, U. A., Frank, S. J., Nill, S., Oelfke, U., et al. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2017.10.020 · Cited by 172
Vrtovec, T., Močnik, D., Strojan, P., Pernuš, F., & Ibragimov, B. (2020) · Medical Physics · doi:10.1002/mp.14320 · Cited by 171
Daisne, J., & Blumhofer, A. (2013) · Radiation Oncology · doi:10.1186/1748-717x-8-154 · Cited by 165
Steenbakkers, R. J. H. M., Duppen, J. C., Fitton, I., Deurloo, K. E. I., Zijp, L., Uitterhoeve, A. L. J., Rodrigus, P. T. R., Kramer, G. W. P., Bussink, J., Jaeger, K. D., et al. (2005) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2005.09.017 · Cited by 162
Fairchild, A. M., Straube, W. L., Laurie, F., & Followill, D. S. (2013) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2013.03.036 · Cited by 161
Boero, I. J., Paravati, A. J., Xu, B., Cohen, E. E. W., Mell, L. K., Le, Q., & Murphy, J. D. (2016) · Journal of Clinical Oncology · doi:10.1200/jco.2015.63.9898 · Cited by 149
Benefits of deep learning for delineation of organs at risk in head and neck cancer
van der Veen, J., Willems, S., Deschuymer, S., Robben, D., Crijns, W., Maes, F., & Nuyts, S. (2019) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2019.05.010 · Cited by 146
Polan, D. F., Brady, S. L., & Kaufman, R. A. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/17/6553 · Cited by 145
Šegedin, B., & Petrič, P. (2016) · Radiology and Oncology · doi:10.1515/raon-2016-0023 · Cited by 142
Measuring the similarity of target volume delineations independent of the number of observers
Kouwenhoven, E., Giezen, M., & Struikmans, H. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/9/018 · Cited by 138
Evaluation of Automatic Atlas-Based Lymph Node Segmentation for Head-and-Neck Cancer
Stapleford, L. J., Lawson, J. D., Perkins, C., Edelman, S., Davis, L. W., McDonald, M. W., Waller, A. F., Schreibmann, E., & Fox, T. H. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.09.023 · Cited by 136
Mir, R., Kelly, S. M., Xiao, Y., Moore, A. J., Clark, C. H., Clementel, E., Corning, C., Ebert, M. A., Hoskin, P., Hurkmans, C., et al. (2020) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2020.05.038 · Cited by 132
Hansen, C. R., Crijns, W., Hussein, M., et al. (2020) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2020.09.033 · Cited by 131
Interobserver variability in radiation therapy plan output: Results of a single-institution study
Berry, S. L., Boczkowski, A., Ma, R., Mechalakos, J., & Hunt, M. A. (2016) · Practical Radiation Oncology · doi:10.1016/j.prro.2016.04.005 · Cited by 128
Hanna, G. G., Hounsell, A. R., & O’Sullivan, J. M. (2010) · Clinical Oncology · doi:10.1016/j.clon.2010.05.006 · Cited by 126
Automatic Segmentation of Whole Breast Using Atlas Approach and Deformable Image Registration
Reed, V. K., Woodward, W. A., Zhang, L., Strom, E. A., Perkins, G. H., Tereffe, W., Oh, J., Yu, T. K., Bedrosian, I., Whitman, G. J., et al. (2008) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2008.07.001 · Cited by 121
Clinical implementation of deep learning contour autosegmentation for prostate radiotherapy
Cha, E., Elguindi, S., Onochie, I., Gorovets, D. J., Deasy, J. O., Zeléfsky, M. J., & Gillespie, E. F. (2021) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2021.02.040 · Cited by 119
Self-citationDosimetric Evaluation of Automatic Segmentation for Adaptive IMRT for Head-and-Neck Cancer
Tsuji, S. Y., Hwang, A., WEINBERG, V. K., Yom, S. S., Quivey, J. M., & Xia, P. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.06.012 · Cited by 116
Voet, P. W. J., Dirkx, M. L. P., Teguh, D. N., Hoogeman, M. S., Levendag, P. C., & Heijmen, B. J. M. (2011) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2010.11.017 · Cited by 115
Tao, C., Yi, J., Chen, N., Ren, W., Cheng, J. C., Tung, S. Y., Kong, L., Lin, S., Pan, J.-J., Zhang, G.-S., et al. (2015) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2015.05.012 · Cited by 104
Gooding, M. J., Smith, A. J., Tariq, M., Aljabar, P., Peressutti, D., van der Stoep, J., Reymen, B., Emans, D., Hattu, D., van Loon, J., et al. (2018) · Medical Physics · doi:10.1002/mp.13200 · Cited by 89
Kaderka, R., Gillespie, E. F., Mundt, R. C., Bryant, A. K., Sanudo-Thomas, C. B., Harrison, A. L., Wouters, E. L., Moiseenko, V., Moore, K. L., Atwood, T. F., et al. (2018) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2018.07.013 · Cited by 84
Self-citationEvaluation of an automatic segmentation algorithm for definition of head and neck organs at risk
Thomson, D. J., Boylan, C., Liptrot, T., Aitkenhead, A. H., Lee, L. W., Yap, B. K., Sykes, A. J., Rowbottom, C. G., & Slevin, N. J. (2014) · Radiation Oncology · doi:10.1186/1748-717x-9-173 · Cited by 75
Mak, R. H., Endres, M. G., Paik, J. H., Sergeev, R. A., Aerts, H., Williams, C. L., Lakhani, K. R., & Guinan, E. C. (2019) · JAMA Oncology · doi:10.1001/jamaoncol.2019.0159 · Cited by 67
Recommendations on how to establish evidence from auto-segmentation software in radiotherapy
Valentini, V., Boldrini, L., Damiani, A., & Muren, L. P. (2014) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2014.09.014 · Cited by 64
Lin, D., Lapen, K., Sherer, M. V., Kantor, J., Zhang, Z., Boyce, L. M., Bosch, W., Korenstein, D., & Gillespie, E. F. (2020) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2020.04.011 · Cited by 59
Self-citationTechnology assessment of automated atlas based segmentation in prostate bed contouring
Hwee, J., Louie, A. V., Gaede, S., Bauman, G. S., D'Souza, D. P., Sexton, T., Lock, M. I., Ahmad, B., & Rodrigues, G. (2011) · Radiation Oncology · doi:10.1186/1748-717x-6-110 · Cited by 58
McCarroll, R. E., Beadle, B. M., Balter, P. A., Burger, H., Cárdenas, C., Dalvie, S., Followill, D. S., Kisling, K. D., Mejia, M. B. A., Naidoo, K., et al. (2018) · Journal of Global Oncology · doi:10.1200/jgo.18.00055 · Cited by 55
Evaluation of atlas‐based auto‐segmentation software in prostate cancer patients
Greenham, S., Dean, J., Fu, C. K. K., Goman, J., Mulligan, J., Tune, D., Sampson, D., Westhuyzen, J., & McKay, M. J. (2014) · Journal of Medical Radiation Sciences · doi:10.1002/jmrs.64 · Cited by 51
Fung, N. T. C., Hung, W. M., Sze, C.-K., Lee, M. C. H., & Ng, W. T. (2019) · Medical dosimetry · doi:10.1016/j.meddos.2019.06.002 · Cited by 49
Tetar, S., Bruynzeel, A. M. E., Bakker, R., Jeulink, M., Slotman, B. J., Oei, S. S., Haasbeek, C. J. A., Jong, K. D., Senan, S., & Lagerwaard, F. J. (2018) · Cureus · doi:10.7759/cureus.2236 · Cited by 48
Dalah, E. Z., Moraru, I., Paulson, E. S., Erickson, B. A., & Li, X. A. (2014) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2014.02.035 · Cited by 47
Zhu, M., Bzdusek, K., Brink, C., Eriksen, J. G., Hansen, O., Jensen, H. A., Gay, H. A., Thorstad, W. L., Widder, J., Brouwer, C. L., et al. (2013) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2013.08.007 · Cited by 46
Challenges for Quality Assurance of Target Volume Delineation in Clinical Trials
Chang, A. T. Y., Tan, L. T., Duke, S. L., & Ng, W. T. (2017) · Frontiers in Oncology · doi:10.3389/fonc.2017.00221 · Cited by 40
Self-citationMulti-Institutional Target Delineation in Oncology Group (2010) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-010-9341-2 · Cited by 37
Auto-segmentation of low-risk clinical target volume for head and neck radiation therapy
Yang, J., Beadle, B. M., Garden, A. S., Gunn, G. B., Rosenthal, D. I., Ang, K. K., Frank, S. J., Williamson, R., Balter, P. A., Court, L. E., et al. (2013) · Practical Radiation Oncology · doi:10.1016/j.prro.2013.03.003 · Cited by 34
Duke, S. L., Tan, L. T., Jensen, N. B. K., Rumpold, T., de Leeuw, A. A. C., Kirisits, C., Lindegaard, J. C., Tanderup, K., Pötter, R., Nout, R. A., et al. (2020) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2020.02.017 · Cited by 33
Self-citationChristiaens, M., Collette, S., Overgaard, J., Grégoire, V., Kaźmierska, J., Castadot, P., Giralt, J., Grant, W., Tomsej, M., Bar-Deroma, R., et al. (2017) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2017.04.019 · Cited by 27
Machine Learning Applications for Head and Neck Imaging
Maleki, F., Le, W., Sananmuang, T., Kadoury, S., & Forghani, R. (2020) · Neuroimaging Clinics of North America · doi:10.1016/j.nic.2020.08.003 · Cited by 19
Interactive image segmentation for radiation treatment planning
Elliott, P. J., Knapman, J. M., & Schlegel, W. (1992) · IBM Systems Journal · doi:10.1147/sj.314.0620 · Cited by 19
Autosegmentation of Images in Radiation Oncology
Chaney, E. L., & Pizer, S. M. (2009) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2009.02.014 · Cited by 11
Gautam, A., Weiss, E., Williamson, J. F., Ford, J. C., Sleeman, W. C., Jan, N., Saraiya, S., Orton, M. D., Zhang, L., & Murphy, M. J. (2013) · Medical Physics · doi:10.1118/1.4813955 · Cited by 5
Metadata
- Authors
- Sherer, M. V., Lin, D., Elguindi, S., Duke, S., Tan, L.-T., Cacicedo, J., Dahele, M., & Gillespie, E. F.
- Venue
- Radiotherapy and Oncology
- Publisher
- Elsevier BV
- Published
- 2021-07
- Volume
- 160
- Pages
- 185-191
- ISSN
- 0167-8140 (ISSN-L)
- OpenAlex
- W3160604201
- Cited by
- 239
- References
- 67
- FWCI
- 23.48
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.