Cited by 110Artificial Intelligence in Healthcare and EducationAdvanced Radiotherapy TechniquesRadiomics and Machine Learning in Medical Imaging

The DOI matches its Crossref record; 83 of the 85 references it cites were found in a registry or an index.

A joint ESTRO and AAPM guideline for development, clinical validation and reporting of artificial intelligence models in radiation therapy

Open access

Abstract

BACKGROUND AND PURPOSE: Artificial Intelligence (AI) models in radiation therapy are being developed with increasing pace. Despite this, the radiation therapy community has not widely adopted these models in clinical practice. A cohesive guideline on how to develop, report and clinically validate AI algorithms might help bridge this gap. METHODS AND MATERIALS: A Delphi process with all co-authors was followed to determine which topics should be addressed in this comprehensive guideline. Separate sections of the guideline, including Statements, were written by subgroups of the authors and discussed with the whole group at several meetings. Statements were formulated and scored as highly recommended or recommended. RESULTS: The following topics were found most relevant: Decision making, image analysis, volume segmentation, treatment planning, patient specific quality assurance of treatment delivery, adaptive treatment, outcome prediction, training, validation and testing of AI model parameters, model availability for others to verify, model quality assurance/updates and upgrades, ethics. Key references were given together with an outlook on current hurdles and possibilities to overcome these. 19 Statements were formulated. CONCLUSION: A cohesive guideline has been written which addresses main topics regarding AI in radiation therapy. It will help to guide development, as well as transparent and consistent reporting and validation of new AI tools and facilitate adoption.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.radonc.2024.110345

Cites

83 of 83 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 85 references

Research works printed but not linked: 6

  1. Fda, 2019, Proposed regulatory framework for modifications to artificial intelligence/machine learning (AI/ML)- based software as a medical device (SaMD). Food and Drug, Administration
  2. Holmes, 2023, Evaluating Large Language Models on a Highly-specialized Topic, Radiation Oncology Physics. Front, Oncol, 17, 1219326
  3. Huang, 2021, Virtual Patient-Specific Quality Assurance of IMRT Using UNet++: Classification, Gamma Passing Rates Prediction, and Dose Difference Prediction. Front, Oncol, %20;11
  4. Liu, Z, Wang, P, Li, Y, Holmes, J, Shu, P, Zhang, L, Liu, C, Liu, N, Zhu, D, Li, X, Li, Q, Patel, S. H., Sio, T. T, Liu, T, Liu, W. RadOnc-GPT: A Large Language Model for Radiation Oncology. arXiv:2309.10160 webpage visited 6-11-2023. · arXiv
  5. Prunaretty, 2023, A multi-centric evaluation of self-learning GAN based pseudo-CT generation software for low field pelvic magnetic resonance imaging. Front, Oncol, 13, 1245054
  6. van de, 2021, Artificial intelligence based treatment planning of radiotherapy for locally advanced breast cancer. Phys Imaging, Radiat Oncol, 20, 111

Cited by

Sorted by citations

Items 101–110 of 110

Metadata

Authors
Hurkmans, C., Bibault, J.-E., Brock, K. K., van Elmpt, W., Feng, M., David Fuller, C., Jereczek-Fossa, B. A., Korreman, S., Landry, G., Madesta, F., Mayo, C., McWilliam, A., Moura, F., Muren, L. P., El Naqa, I., Seuntjens, J., Valentini, V., & Velec, M.
Affiliations
  • Catharina Ziekenhuis (NL)
  • Hôpital Européen Georges-Pompidou (FR)
  • The University of Texas MD Anderson Cancer Center (US)
  • Maastricht University Medical Centre (NL)
  • University of California, San Francisco (US)
  • Aarhus University (DK)
  • LMU Klinikum (DE)
  • University Medical Center Hamburg-Eppendorf (DE)
  • University of Michigan (US)
  • University of Manchester (GB)
  • University Health Network (CA)
  • Università Cattolica del Sacro Cuore (IT)
  • University of Toronto (CA)
Corresponding author
Hurkmans, Coen
Venue
Radiotherapy and Oncology
Publisher
Elsevier BV
Published
2024-08
Volume
197
Pages
110345
ISSN
0167-8140 (ISSN-L)
OpenAlex
W4399327635
Cited by
110
References
85
Citations by year
2026: 56 · 2025: 46 · 2024: 7
FWCI
10.19
Type
journal article
Language
en
Open access
Locations
  • Radiotherapy and Oncology (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • TU/e Research Portal (publishedVersion, cc-by)
  • Digital Commons-TMC (Texas Medical Center) (submittedVersion)
  • Research Publications (Maastricht University) (submittedVersion, cc-by)
Funders
European SocieTy for Radiotherapy and Oncology
Topics
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiomics and Machine Learning in Medical Imaging
Keywords
artificial intelligence, radiotherapy, treatment planning, adaptive radiotherapy, image segmentation, patient-specific quality assurance, outcome prediction, AI ethics, clinical adoption of AI, Delphi consensus
MeSH terms
Algorithms, Artificial Intelligence, Delphi Technique, Humans, Radiotherapy, Radiotherapy Planning, Computer-Assisted, Radiation Oncology

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review