Environmental benefits arising from demountable steel-concrete composite floor systems in buildings
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
This paper presents an assessment and quantification of the environmental impacts arising from different steel-concrete composite floor systems. In particular, a demountable composite floor system using pretensioned high-strength friction grip bolts as shear connectors is compared with three conventional composite floor systems that use welded shear studs as shear connectors. The first type promotes the end-of-life scenario of disassembly and reuse of structural elements, while the conventional systems are related to the current practices of waste management for building materials, i.e. demolition and recycling. To analyse these different structural systems and relative scenarios, a comparative Life Cycle Assessment investigating two entire life cycles of the materials is developed. Based on the evaluation of several impact categories, the building with demountable composite floor system is identified as the most environmentally friendly solution among all the considered structural solutions, and the saving of emissions and resources is quantified for each impact category.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The authors also discussed that the deconstruction of the demountable composite structure takes more time compared with demolition, which results in the emission of higher amounts of GHGs since the heavy machinery and equipment need to operate for longer periods (Brambilla et al., 2019).”
From Components reuse in the building sector – A systematic review (2020) · cites this paper as Brambilla et al., 2019
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The ecoinvent database version 3 (part I): overview and methodology
Wernet, G., Bauer, C., Steubing, B., Reinhard, J., Moreno-Ruiz, E., & Weidema, B. (2016) · The International Journal of Life Cycle Assessment · doi:10.1007/s11367-016-1087-8 · Cited by 5,564 · cited 2×
“4 [29] and processed with the software SimaPro [30] in accordance with the same”
BackgroundMethodSustainable Materials: with both eyes open
Cullen, J. M., Allwood, J. M., et al. (2012) · Cambridge University Engineering Department Publications Database · Cited by 573
Bolted shear connectors vs. headed studs behaviour in push-out tests
Pavlović, M., Marković, Z., Veljković, M., & Buđevac, D. (2013) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2013.05.003 · Cited by 536
Sustainable materials with both eyes open
(2013) · Choice Reviews Online · doi:10.5860/choice.50-3871 · Cited by 434
LCA databases focused on construction materials: A review
Martínez-Rocamora, A., Solís-Guzmán, J., & Marrero, M. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.12.243 · Cited by 307
Behavior of post-installed shear connectors under static and fatigue loading
Kwon, G., Engelhardt, M. D., & Klingner, R. E. (2009) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2009.09.012 · Cited by 271
Behavior of High-Strength Friction-Grip Bolted Shear Connectors in Sustainable Composite Beams
Liu, X., Bradford, M. A., & Lee, M. S. S. (2014) · Journal of Structural Engineering · doi:10.1061/(asce)st.1943-541x.0001090 · Cited by 186
Directive 2002/58/EC of the European Parliament and of the Council
(2016) · Fundamental Texts On European Private Law · doi:10.5040/9781782258674.0020 · Cited by 173
López-Mesa, B., Pitarch, Á. M., Tomás, A., & Navarro, T. G. (2008) · Building and Environment · doi:10.1016/j.buildenv.2008.05.017 · Cited by 145
Viability and performance of demountable composite connectors
Moynihan, M. C., & Allwood, J. M. (2014) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2014.03.008 · Cited by 123
Suwaed, A. S. H., & Karavasilis, T. L. (2017) · Journal of Bridge Engineering · doi:10.1061/(asce)be.1943-5592.0001080 · Cited by 101
Sustainable materials: With both eyes open
Bauer, S. (2012) · Materials Today · doi:10.1016/s1369-7021(12)70169-4 · Cited by 98
MARSHALL, W. T., Nelson, H. M., & Banerjee, H. (1971) · The Structural Engineer · Cited by 96
Recent research on composite beams with demountable shear connectors
Lam, D., Dai, X., Ashour, A. F., & Rehman, N. (2017) · Steel Construction · doi:10.1002/stco.201710016 · Cited by 49
Understanding the total life cycle cost implications of reusing structural steel
Yeung, J., Walbridge, S., Haas, C., & Saari, R. (2017) · Environment Systems and Decisions · doi:10.1007/s10669-016-9621-6 · Cited by 46
Pushout Tests with High Strength Bolt Shear Connectors
Dallam, L. N. (1966) · MOspace Institutional Repository (University of Missouri) · Cited by 32
The "Donor Skelet": Designing with reused structural concrete elements
Glias, A. (2013) · Research Repository (Delft University of Technology) · Cited by 22
Life Cycle Assessment of Tall Building Structural Systems
Trabucco, D., Wood, A., Vassart, O., Popa, N., & Davies, D. W. (2015) · AirIuav (Università Iuav di Venezia) · Cited by 18
Reuse of hollow core slabs from office buildings to residential buildings
Naber, N. (2012) · Research Repository (Delft University of Technology) · Cited by 6
Braendstrup, C. (2017) · Research Repository (Delft University of Technology) · Cited by 6
Environmental emissions and energy use from the structural steel erection process: a case study
Haney, J. H., Guggemos, A. A., Criswell, M., & Clevenger, C. (2007) · Digital Collections of Colorado (Colorado State University) · doi:10.25675/3.023596 · Cited by 3
Feidaki, E., & Vasdravellis, G. (2017) · ce/papers · doi:10.1002/cepa.251 · Cited by 3
Self-citationComparative structure cost of modern commercial buildings
Hicks, S. J., Lawson, R. M., Rackham, J. W., & Fordham, P. (2004) · doi:10.13140/rg.2.2.10468.58248 · Cited by 1
SERVICE-LOAD MODELLING OF DECONSTRUCTABLE COMPOSITE BEAMS WITH FRICTION-GRIP BOLTED SHEAR CONNECTION
Bradford, M. A. (2014) · Cross Connect (Southern Cross University) · Cited by 1
Deconstructable Steel-Concrete Shear Connection for Sustainable Composite Floor Systems
Wang, L., Brown, C., Webster, M. D., & Hajjar, J. F. (2014) · Cited by 1
Sustainable composite steel-concrete construction
Brambilla, G. (2018) · Cited by 1
Self-citation
Cited by
(2023) · Cambridge University Press eBooks · doi:10.1017/9781009157926 · Cited by 2,605
López Ruiz, L. A., Roca Ramón, X., & Gassó Domingo, S. (2020) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2019.119238 · Cited by 538
Giorgi, S., Lavagna, M., Wang, K., Osmani, M., Liu, G., & Campioli, A. (2022) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2022.130395 · Cited by 346
Self-citationLinks between circular economy and climate change mitigation in the built environment
Gallego-Schmid, A., Chen, H.-M., Sharmina, M., & Mendoza, J. M. F. (2020) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2020.121115 · Cited by 340
Minunno, R., O'Grady, T., Morrison, G. M., & Gruner, R. L. (2020) · Resources, Conservation and Recycling · doi:10.1016/j.resconrec.2020.104855 · Cited by 300
Metadata
- Authors
- Brambilla, G., Lavagna, M., Vasdravellis, G., & Castiglioni, C. A.
- Venue
- Resources, Conservation and Recycling
- Publisher
- Elsevier BV
- Published
- 2019-02
- Volume
- 141
- Pages
- 133-142
- ISSN
- 0921-3449 (ISSN-L)
- OpenAlex
- W2898593626
- Cited by
- 136
- References
- 28
- FWCI
- 3.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.