Validation of a computational platform for the analysis of the physiologic mechanisms of a human experimental model of hemorrhage
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Computational models of integrative physiology may serve as a framework for understanding the complex adaptive responses essential for homeostasis in critical illness and resuscitation and may provide insights for design of diagnostics and therapeutics. In this study a computer model of human physiology was compared to results obtained from experiments using Lower Body Negative Pressure (LBNP) analog model of human hemorrhage. LBNP has been demonstrated to produce physiologic changes in humans consistent with hemorrhage. The computer model contains over 4000 parameters that describe the detailed integration of physiology based upon basic physical principles and established biologic interactions. The LBNP protocol consisted of a 5 min rest period (0 mmHg) followed by 5 min of chamber decompression of the lower body to −15, −30, −45, and −60 mmHg and additional increments of −10 mmHg every 5 min until the onset of hemodynamic decompensation (n = 20). Physiologic parameters recorded include mean arterial pressure (MAP), cardiac output (CO), and venous oxygen saturation (SVO2; from peripheral venous blood), during the last 30 s at each LBNP level. The computer model analytic procedure recreates the investigational protocol for a virtual individual in an In Silico environment. After baseline normalization, the model predicted measurements for MAP, CO, and SVO2 were compared to those observed through the entire range of LBNP. Differences were evaluated using standard statistical performance error measurements (median performance error (PE) <5%). The simulation results closely tracked the average changes observed during LBNP. The predicted MAP fell outside the standard error measurement for the experimental data at only LBNP −30 mmHg while CO was more variable. The predicted SVO2 fell outside the standard error measurement for the experimental data only during the post-LBNP recovery point. However, the statistical median PE measurement was found to be within the 5% objective error measure (1.3% for MAP, −3.5% for CO, and 3.95% for SVO2). The computer model was found to accurately predict the experimental results observed using LBNP. The model should be explored as a platform for studying concepts and physiologic mechanisms of hemorrhage including its diagnosis and treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Parati, G., Casadei, R., Groppelli, A., Di Rienzo, M., & Mancia, G. (1989) · Hypertension · doi:10.1161/01.hyp.13.6.647 · Cited by 899
Circulation: Overall Regulation
Guyton, A. C., Coleman, T. G., & Granger, H. J. (1972) · Annual Review of Physiology · doi:10.1146/annurev.ph.34.030172.000305 · Cited by 870
Self-citationComputer Models for Designing Hypertension Experiments and Studying Concepts
Guyton, A. C., Montani, J.-P., Hall, J. E., & Manning, R. D. (1988) · The American Journal of the Medical Sciences · doi:10.1097/00000441-198804000-00018 · Cited by 20
Cited by
HumMod: A Modeling Environment for the Simulation of Integrative Human Physiology
Hester, R. L., Brown, A. J., Husband, L., Iliescu, R., Pruett, D., Summers, R., & Coleman, T. G. (2011) · Frontiers in Physiology · doi:10.3389/fphys.2011.00012 · Cited by 159
“We judge validity on the criteria established by Summers et al. (2009).”
Self-citationParvinian, B., Pathmanathan, P., Daluwatte, C., Yaghouby, F., Gray, R. A., Weininger, S., Morrison, T. M., & Scully, C. G. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.00220 · Cited by 44
“Summers et al. (2009) also recognized that whenever possible, model outputs should be compared with experimental outcomes for more consequential conclusions about model validity.”
MethodResultMechanisms of blood pressure salt sensitivity: new insights from mathematical modeling
Clemmer, J. S., Pruett, W. A., Coleman, T. G., Hall, J. E., & Hester, R. L. (2017) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00353.2016 · Cited by 41
Self-citationSimulating a virtual population's sensitivity to salt and uninephrectomy
Clemmer, J. S., Hester, R. L., & Pruett, W. A. (2018) · Interface Focus · doi:10.1098/rsfs.2016.0134 · Cited by 7
Self-citation
Metadata
- Authors
- Summers, R. L., Ward, K. R., Witten, T., Convertino, V. A., Ryan, K. L., Coleman, T. G., & Hester, R. L.
- Venue
- Resuscitation
- Publisher
- Elsevier BV
- Published
- 2009-12
- Volume
- 80
- Issue
- 12
- Pages
- 1405-1410
- ISSN
- 0300-9572 (ISSN-L)
- OpenAlex
- W2101137381
- Cited by
- 57
- References
- 3
- FWCI
- 2.77
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation of a computational platform for the analysis of the physiologic mechanisms of a human experimental model of hemorrhage. https://app.cochat.ai/papers/10.1016/j.resuscitation.2009.09.001
- The paper
- Summers, R. L., Ward, K. R., Witten, T., Convertino, V. A., Ryan, K. L., Coleman, T. G., & Hester, R. L. (2009). Validation of a computational platform for the analysis of the physiologic mechanisms of a human experimental model of hemorrhage. Resuscitation. https://doi.org/10.1016/j.resuscitation.2009.09.001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.