Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 366

The DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.

“Identifying the hospitalised patient in crisis”—A consensus conference on the afferent limb of Rapid Response Systems

Open access
DeVita, Michael A., Smith, Gary B., Adam, Sheila K., Adams-Pizarro, Inga, Buist, Michael, Bellomo, Rinaldo, Bonello, Robert, Cerchiari, Erga, Farlow, Barbara, Goldsmith, Donna, Haskell, Helen, Hillman, Kenneth, Howell, Michael, Hravnak, Marilyn, Hunt, Elizabeth A., Hvarfner, Andreas, Kellett, John, Lighthall, Geoffrey K., Lippert, Anne, Lippert, Freddy K., Mahroof, Razeen, Myers, Jennifer S., Rosen, Mark, Reynolds, Stuart, Rotondi, Armando, Rubulotta, Francesca, Winters, Bradford·2010·Resuscitation

Abstract

BACKGROUND Most reports of Rapid Response Systems (RRS) focus on the efferent, response component of the system, although evidence suggests that improved vital sign monitoring and recognition of a clinical crisis may have outcome benefits. There is no consensus regarding how best to detect patient deterioration or a clear description of what constitutes patient monitoring. METHODS A consensus conference of international experts in safety, RRS, healthcare technology, education, and risk prediction was convened to review current knowledge and opinion on clinical monitoring. Using established consensus procedures, four topic areas were addressed: (1) To what extent do physiologic abnormalities predict risk for patient deterioration? (2) Do workload changes and their potential stresses on the healthcare environment increase patient risk in a predictable manner? (3) What are the characteristics of an "ideal" monitoring system, and to what extent does currently available technology meet this need? and (4) How can monitoring be categorized to facilitate comparing systems? RESULTS AND CONCLUSIONS The major findings include: (1) vital sign aberrations predict risk, (2) monitoring patients more effectively may improve outcome, although some risk is random, (3) the workload implications of monitoring on the clinical workforce have not been explored, but are amenable to study and should be investigated, (4) the characteristics of an ideal monitoring system are identifiable, and it is possible to categorize monitoring modalities. It may also be possible to describe monitoring levels, and a system is proposed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.resuscitation.2009.12.008

Cites

57 of 57 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 57 references

Cited by

See all 366

Metadata

Authors
DeVita, M. A., Smith, G. B., Adam, S. K., Adams-Pizarro, I., Buist, M., Bellomo, R., Bonello, R., Cerchiari, E., Farlow, B., Goldsmith, D., Haskell, H., Hillman, K., Howell, M., Hravnak, M., Hunt, E. A., Hvarfner, A., Kellett, J., Lighthall, G. K., Lippert, A., Lippert, F. K., Mahroof, R., Myers, J. S., Rosen, M., Reynolds, S., Rotondi, A., Rubulotta, F., & Winters, B.
Venue
Resuscitation
Publisher
Elsevier BV
Published
2010-04
Volume
81
Issue
4
Pages
375-382
ISSN
0300-9572 (ISSN-L)
OpenAlex
W2032916871
Cited by
366
References
57
FWCI
26.70
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: “Identifying the hospitalised patient in crisis”—A consensus conference on the afferent limb of Rapid Response Systems. https://app.cochat.ai/papers/10.1016/j.resuscitation.2009.12.008
The paper
DeVita, M. A., Smith, G. B., Adam, S. K., Adams-Pizarro, I., Buist, M., Bellomo, R., Bonello, R., Cerchiari, E., Farlow, B., Goldsmith, D., Haskell, H., Hillman, K., Howell, M., Hravnak, M., Hunt, E. A., Hvarfner, A., Kellett, J., Lighthall, G. K., Lippert, A., . . . Winters, B. (2010). “Identifying the hospitalised patient in crisis”—A consensus conference on the afferent limb of Rapid Response Systems. Resuscitation. https://doi.org/10.1016/j.resuscitation.2009.12.008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.