Cited by 368Non-Invasive Vital Sign MonitoringECG Monitoring and AnalysisHeart Rate Variability and Autonomic Control

Signal Quality Indices for the Electrocardiogram and Photoplethysmogram: Derivation and Applications to Wireless Monitoring

Open access
Orphanidou, Christina, Bonnici, Timothy, Charlton, Peter, Clifton, David, Vallance, David, Tarassenko, Lionel·2014·IEEE Journal of Biomedical and Health Informatics

Abstract

The identification of invalid data in recordings obtained using wearable sensors is of particular importance since data obtained from mobile patients is, in general, noisier than data obtained from nonmobile patients. In this paper, we present a signal quality index (SQI), which is intended to assess whether reliable heart rates (HRs) can be obtained from electrocardiogram (ECG) and photoplethysmogram (PPG) signals collected using wearable sensors. The algorithms were validated on manually labeled data. Sensitivities and specificities of 94% and 97% were achieved for the ECG and 91% and 95% for the PPG. Additionally, we propose two applications of the SQI. First, we demonstrate that, by using the SQI as a trigger for a power-saving strategy, it is possible to reduce the recording time by up to 94% for the ECG and 93% for the PPG with only minimal loss of valid vital-sign data. Second, we demonstrate how an SQI can be used to reduce the error in the estimation of respiratory rate (RR) from the PPG. The performance of the two applications was assessed on data collected from a clinical study on hospital patients who were able to walk unassisted.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jbhi.2014.2338351

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Wearables already assess PPG signal quality in order to determine whether heart rate values are accurate.

    “Wearables already assess PPG signal quality in order to determine whether HR values are accurate [86].”

    From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [86]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Orphanidou, C., Bonnici, T., Charlton, P., Clifton, D., Vallance, D., & Tarassenko, L.
Affiliations
  • University of Oxford (GB)
  • King's College London (GB)
  • John Radcliffe Hospital (GB)
Venue
IEEE Journal of Biomedical and Health Informatics
Published
2014
Volume
19
Issue
3
Pages
1-1
ISSN
  • 2168-2194 (ISSN-L)
  • 2168-2208
OpenAlex
W2049755262
Cited by
368
References
17
Citations by year
2026: 27 · 2025: 31 · 2024: 29 · 2023: 36 · 2022: 50 · 2021: 47 · 2020: 37 · 2019: 29 · 2018: 28 · 2017: 28 · 2016: 22 · 2015: 4
FWCI
9.34
Type
journal article
Language
en
Open access
Locations
  • IEEE Journal of Biomedical and Health Informatics (publishedVersion)
  • PubMed (publishedVersion)
  • Research Portal (King's College London) (submittedVersion, other-oa)
Funders
Engineering and Physical Sciences Research Council (EP/F058845/1, EP/H019944/1)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
Keywords
signal quality index, electrocardiogram, photoplethysmogram, wearable sensors, wireless monitoring, heart rate estimation, respiratory rate estimation, hospitalized patients
MeSH terms
Electrocardiography, Heart Rate, Humans, Signal Processing, Computer-Assisted, Databases, Factual, Photoplethysmography, Respiratory Rate, Wireless Technology

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review