CoChat

Comparison of the Between the Flags calling criteria to the MEWS, NEWS and the electronic Cardiac Arrest Risk Triage (eCART) score for the identification of deteriorating ward patients

Open access
Green, Malcolm, Lander, Harvey, Snyder, Ashley, Hudson, Paul, Churpek, Matthew, Edelson, Dana · 2018 · Resuscitation
Cited by 149

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Introduction: Traditionally, paper based observation charts have been used to identify deteriorating patients, with emerging recent electronic medical records allowing electronic algorithms to risk stratify and help direct the response to deterioration. Objective(s): We sought to compare the Between the Flags (BTF) calling criteria to the Modified Early Warning Score (MEWS), National Early Warning Score (NEWS) and electronic Cardiac Arrest Risk Triage (eCART) score. Design and Participants: Multicenter retrospective analysis of electronic health record data from all patients admitted to five US hospitals from November 2008-August 2013. Main outcome measures: Cardiac arrest, ICU transfer or death within 24 hours of a score Results: Overall accuracy was highest for eCART, with an AUC of 0.801 (95% CI 0.799–0.802), followed by NEWS, MEWS and BTF respectively (0.718 [0.716–0.720]; 0.698 [0.696–0.700]; 0.663 [0.661–0.664]). BTF criteria had a high risk (Red Zone) specificity of 95.0% and a moderate risk (Yellow Zone) specificity of 27.5%, which corresponded to MEWS thresholds of >=4 and >=2, NEWS thresholds of >=5 and >=2, and eCART thresholds of >=12 and >=4, respectively. At those thresholds, eCART caught 22 more adverse events per 10,000 patients than BTF using the moderate risk criteria and 13 more using high risk criteria, while MEWS and NEWS identified the same or fewer. Conclusion(s): An electronically generated eCART score was more accurate than commonly used paper based observation tools for predicting the composite outcome of in-hospital cardiac arrest, ICU transfer and death within 24 hours of observation. The outcomes of this analysis lend weight for a move towards an algorithm based electronic risk identification tool for deteriorating patients to ensure earlier detection and prevent adverse events in the hospital.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.resuscitation.2017.10.028

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 149

Metadata

Authors
Green, M., Lander, H., Snyder, A., Hudson, P., Churpek, M., & Edelson, D.
Venue
Resuscitation
Publisher
Elsevier BV
Published
2018-02
Volume
123
Pages
86-91
ISSN
0300-9572 (ISSN-L)
OpenAlex
W2770006511
Cited by
149
References
2
FWCI
10.87
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of the Between the Flags calling criteria to the MEWS, NEWS and the electronic Cardiac Arrest Risk Triage (eCART) score for the identification of deteriorating ward patients. https://app.cochat.ai/papers/10.1016/j.resuscitation.2017.10.028
The paper
Green, M., Lander, H., Snyder, A., Hudson, P., Churpek, M., & Edelson, D. (2018). Comparison of the Between the Flags calling criteria to the MEWS, NEWS and the electronic Cardiac Arrest Risk Triage (eCART) score for the identification of deteriorating ward patients. Resuscitation. https://doi.org/10.1016/j.resuscitation.2017.10.028

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.