Characterisation of titanium oxide layers using Raman spectroscopy and optical profilometry: Influence of oxide properties
Open accessThe DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
This study evaluates the use of a combination of Raman spectroscopy and optical profilometry as a surface characterisation technique for the examination of oxide layers grown on titanium metal substrates. The titanium oxide layers with thickness of up to 8 µm, were obtained using a low-pressure oxygen microwave plasma treatment of the titanium metal substrate. The effect of the microwave plasma processing conditions (input power, pressure and treatment time) on the Raman bandwidth, intensity and peak position was evaluated. Also, the effect of these processing conditions on the surface roughness parameters (Sa, Sdq, Ssk and Sku) of the oxide layers was investigated. Analysis of the peak positions of Eg and A1g modes indicated that the effects of input power and chamber pressure was to induce a shift towards the lower frequency with increasing input power and pressure (1–2 kPa). The intensity of the Raman bands was found to be dependent on the morphology and surface chemistry of the oxide layer. The intensity of Raman band (A1g), was found to be particularly influenced by the average surface roughness (Sa) and the crystallite size. Exponential and polynomial relations were found to correlate with these properties. A two-latent variable Partial Least Squares Regression model developed on Raman spectral data could predict surface roughness with a coefficient of determination (R2) of approx. 0.87 when applied to the testing of an independent set of titanium oxide test coatings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Photolysis of Water at a Semiconductor Electrode
FUJISHIMA, A., & HONDA, K. (1972) · Nature · doi:10.1038/238037a0 · Cited by 34,169
Probing Single Molecules and Single Nanoparticles by Surface-Enhanced Raman Scattering
Nie, S., & Emory, S. R. (1997) · Science · doi:10.1126/science.275.5303.1102 · Cited by 10,238
The Scherrer Formula for X-Ray Particle Size Determination
Patterson, A. L. (1939) · Physical Review · doi:10.1103/physrev.56.978 · Cited by 9,152 · cited 1×
“The average crystallite size of the samples treated with various input power, pressure and time was estimated from the most intense (110) XRD peak using the Scherrer equation [38,39]: τ = (kλ)/ (β”
MethodSingle Molecule Detection Using Surface-Enhanced Raman Scattering (SERS)
Kneipp, K., Wang, Y., Kneipp, H., Perelman, L. T., Itzkan, I., Dasari, R. R., & Feld, M. S. (1997) · Physical Review Letters · doi:10.1103/physrevlett.78.1667 · Cited by 6,816
Scherrer after sixty years: A survey and some new results in the determination of crystallite size
Langford, J. I., & Wilson, A. J. C. (1978) · Journal of Applied Crystallography · doi:10.1107/s0021889878012844 · Cited by 3,903 · cited 1×
“The average crystallite size of the samples treated with various input power, pressure and time was estimated from the most intense (110) XRD peak using the Scherrer equation [38,39]: τ = (kλ)/ (β”
MethodSurface modification of titanium, titanium alloys, and related materials for biomedical applications
LIU, X., CHU, P., & DING, C. (2004) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2004.11.001 · Cited by 3,487 · cited 1×
“The physical methods include the use of thermal treatment, thermal spraying, physical vapour deposition and ion implantation techniques, while the chemical oxidation methods include the use of sol–gel treatment, electrochemical treatments (anodic oxidation) and chemical vapour deposition (CVD) [2].”
MethodTheory of the oxidation of metals
Cabrera, N., & Mott, N. F. (1949) · Reports on Progress in Physics · doi:10.1088/0034-4885/12/1/308 · Cited by 2,986
Spectroscopy of Single Hemoglobin Molecules by Surface Enhanced Raman Scattering
Xu, H., Bjerneld, E. J., Käll, M., & Börjesson, L. (1999) · Physical Review Letters · doi:10.1103/physrevlett.83.4357 · Cited by 2,362
The one phonon Raman spectrum in microcrystalline silicon
Richter, H., Wang, Z. P., & Ley, L. (1981) · Solid State Communications · doi:10.1016/0038-1098(81)90337-9 · Cited by 2,348
Raman spectrum of anatase, TiO 2
Ohsaka, T., Izumi, F., & Fujiki, Y. (1978) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1250070606 · Cited by 2,327
Metadata
- Authors
- Ekoi, E. J., Gowen, A., Dorrepaal, R., & Dowling, D. P.
- Venue
- Results in Physics
- Publisher
- Elsevier BV
- Published
- 2019-03
- Volume
- 12
- Pages
- 1574-1585
- ISSN
- 2211-3797 (ISSN-L)
- OpenAlex
- W2912374369
- Cited by
- 168
- References
- 42
- FWCI
- 10.08
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterisation of titanium oxide layers using Raman spectroscopy and optical profilometry: Influence of oxide properties. https://app.cochat.ai/papers/10.1016/j.rinp.2019.01.054
- The paper
- Ekoi, E. J., Gowen, A., Dorrepaal, R., & Dowling, D. P. (2019). Characterisation of titanium oxide layers using Raman spectroscopy and optical profilometry: Influence of oxide properties. Results in Physics. https://doi.org/10.1016/j.rinp.2019.01.054
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.