CoChat

A review on liquid air energy storage: History, state of the art and recent developments

Open access
Borri, Emiliano, Tafone, Alessio, Romagnoli, Alessandro, Comodi, Gabriele · 2021 · Renewable and Sustainable Energy Reviews
Cited by 210

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Abstract

Abstract Liquid air energy storage (LAES) represents one of the main alternatives to large-scale electrical energy storage solutions from medium to long-term period such as compressed air and pumped hydro energy storage. Indeed, characterized by one of the highest volumetric energy density (≈200 kWh/m3), LAES can overcome the geographical constraints from which the actual mature large-scale electrical energy storage technologies suffer from. LAES is based on the concept that air can be liquefied, stored, and used at a later time to produce electricity. Although the liquefaction of air has been studied for over a century, the first concept of using cryogenics as energy storage was proposed for the first time in 1977 and rediscovered only in recent times. Indeed, the need for alternative energy vectors in the energy system attracted many researchers to discover the potential of the use of cryogenic media. This has brought the realization of a first LAES pilot plant and a growing number of studies regarding LAES systems. The main drawback of this technology is the low round-trip efficiency that can be estimated around 50–60% for large-scale systems. However, due to its thermo-mechanical nature, LAES is a versatile energy storage concept that can be easily integrated with other thermal energy systems or energy sources in a wide range of applications. Most of the literature published is based on thermodynamic and economic analysis focusing on different LAES configurations. This paper provides a collection of the papers published on LAES and it classifies the various studies conducted in different categories. Future perspectives show that hybrid LAES solutions with efficient design of the waste energy recovery sections are the most promising configuration to enhance the techno-economic performance of the stand-alone system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.rser.2020.110572

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Cited by

See all 210

Metadata

Authors
Borri, E., Tafone, A., Romagnoli, A., & Comodi, G.
Venue
Renewable and Sustainable Energy Reviews
Publisher
Elsevier BV
Published
2021-03
Volume
137
Pages
110572
ISSN
1364-0321 (ISSN-L)
OpenAlex
W3110670875
Cited by
210
References
25
FWCI
11.14
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A review on liquid air energy storage: History, state of the art and recent developments. https://app.cochat.ai/papers/10.1016/j.rser.2020.110572
The paper
Borri, E., Tafone, A., Romagnoli, A., & Comodi, G. (2021). A review on liquid air energy storage: History, state of the art and recent developments. Renewable and Sustainable Energy Reviews. https://doi.org/10.1016/j.rser.2020.110572

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.