The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Pre-flight calibration and initial data processing for the ChemCam laser-induced breakdown spectroscopy instrument on the Mars Science Laboratory rover
Open accessAbstract
The ChemCam instrument package on the Mars Science Laboratory rover, Curiosity, is the first planetary science instrument to employ laser-induced breakdown spectroscopy (LIBS) to determine the compositions of geological samples on another planet. Pre-processing of the spectra involves subtracting the ambient light background, removing noise, removing the electron continuum, calibrating for the wavelength, correcting for the variable distance to the target, and applying a wavelength-dependent correction for the instrument response. Further processing of the data uses multivariate and univariate comparisons with a LIBS spectral library developed prior to launch as well as comparisons with several on-board standards post-landing. The level-2 data products include semi-quantitative abundances derived from partial least squares regression. A LIBS spectral library was developed using 69 rock standards in the form of pressed powder disks, glasses, and ceramics to minimize heterogeneity on the scale of the observation (350–550 μm dia.). The standards covered typical compositional ranges of igneous materials and also included sulfates, carbonates, and phyllosilicates. The provenance and elemental and mineralogical compositions of these standards are described. Spectral characteristics of this data set are presented, including the size distribution and integrated irradiances of the plasmas, and a proxy for plasma temperature as a function of distance from the instrument. Two laboratory-based clones of ChemCam reside in Los Alamos and Toulouse for the purpose of adding new spectra to the database as the need arises. Sensitivity to differences in wavelength correlation to spectral channels and spectral resolution has been investigated, indicating that spectral registration needs to be within half a pixel and resolution needs to match within 1.5 to 2.6 pixels. Absolute errors are tabulated for derived compositions of each major element in each standard using PLS regression. Sources of errors are investigated and discussed, and methods for improving the analytical accuracy of compositions derived from ChemCam spectra are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Wavelet Tour of Signal Processing
(1999) · Elsevier eBooks · doi:10.1016/b978-0-12-466606-1.x5000-4 · Cited by 16,227
Independent component analysis, A new concept?
Comon, P. (1994) · Signal Processing · doi:10.1016/0165-1684(94)90029-9 · Cited by 8,205
Limits for qualitative detection and quantitative determination. Application to radiochemistry
Currie, L. A. (1968) · Analytical Chemistry · doi:10.1021/ac60259a007 · Cited by 4,553
Handbook of Laser‐Induced Breakdown Spectroscopy
Cremers, D. A., & Radziemski, L. J. (2006) · doi:10.1002/0470093013 · Cited by 2,374
Handbook of Chemometrics and Qualimetrics: Part A
(1998) · Data Handling in Science and Technology · doi:10.1016/s0922-3487(97)x8000-1 · Cited by 2,027
1994 COMPILATION OF WORKING VALUES AND SAMPLE DESCRIPTION FOR 383 GEOSTANDARDS
GOVINDARAJU, K. (1994) · Geostandards Newsletter · doi:10.1046/j.1365-2494.1998.53202081.x-i1 · Cited by 1,631
Hahn, D. W., & Omenetto, N. (2012) · Applied Spectroscopy · doi:10.1366/11-06574 · Cited by 1,497
GeoReM: A New Geochemical Database for Reference Materials and Isotopic Standards
Jochum, K. P., Nohl, U., Herwig, K., et al. (2005) · Geostandards and Geoanalytical Research · doi:10.1111/j.1751-908x.2005.tb00904.x · Cited by 1,452
1994 REPORT ON ZINNWALDITE ZW‐C ANALYSED BY NINETY‐TWO GIT‐IWG MEMBER‐LABORATORIES
GOVINDARAJU, K., RUBESKA, I., & PAUKERT, T. (1994) · Geostandards Newsletter · doi:10.1111/j.1751-908x.1994.tb00502.x · Cited by 1,138
Hahn, D. W., & Omenetto, N. (2010) · Applied Spectroscopy · doi:10.1366/000370210793561691 · Cited by 1,068
Multiway calibration. Multilinear PLS
Bro, R. (1996) · Journal of Chemometrics · doi:10.1002/(sici)1099-128x(199601)10:1<47::aid-cem400>3.0.co;2-c · Cited by 714
Cristoforetti, G., De Giacomo, A., Dell'Aglio, M., Legnaioli, S., Tognoni, E., Palleschi, V., & Omenetto, N. (2010) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2009.11.005 · Cited by 682
Wiens, R. C., Maurice, S., Barraclough, B., Saccoccio, M., Barkley, W. C., Bell, J. F., Bender, S., Bernardin, J., Blaney, D., Blank, J., et al. (2012) · Space Science Reviews · doi:10.1007/s11214-012-9902-4 · Cited by 554
Self-citationMaurice, S., Wiens, R. C., Saccoccio, M., Barraclough, B., Gasnault, O., Forni, O., Mangold, N., Baratoux, D., Bender, S., Berger, G., et al. (2012) · Space Science Reviews · doi:10.1007/s11214-012-9912-2 · Cited by 483
Self-citationIndependent Component Analysis
Comon, P. (1992) · HAL (Le Centre pour la Communication Scientifique Directe) · Cited by 469
Identification of Carbonate-Rich Outcrops on Mars by the Spirit Rover
Morris, R. V., Ruff, S. W., Gellert, R., Ming, D. W., Arvidson, R. E., Clark, B. C., Golden, D. C., Siebach, K., Klingelhöfer, G., Schröder, C., et al. (2010) · Science · doi:10.1126/science.1189667 · Cited by 447
Characterization of Laser-Induced Breakdown Spectroscopy (LIBS) for Application to Space Exploration
Knight, A. K., Scherbarth, N. L., Cremers, D. A., & Ferris, M. J. (2000) · Applied Spectroscopy · doi:10.1366/0003702001949591 · Cited by 432
Chemistry and mineralogy of outcrops at Meridiani Planum
Clark, B. C., Morris, R. V., McLennan, S. M., Gellert, R., Jolliff, B., Knoll, A. H., Squyres, S. W., Lowenstein, T. K., Ming, D. W., Tosca, N. J., et al. (2005) · Earth and Planetary Science Letters · doi:10.1016/j.epsl.2005.09.040 · Cited by 400
Aguilera, J. A., & Aragón, C. (2004) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2004.08.003 · Cited by 370
A procedure for correcting self-absorption in calibration free-laser induced breakdown spectroscopy
Bulajic, D., Corsi, M., Cristoforetti, G., Legnaioli, S., Palleschi, V., Salvetti, A., & Tognoni, E. (2002) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/s0584-8547(01)00398-6 · Cited by 368
Clegg, S. M., Sklute, E., Dyar, M. D., Barefield, J. E., & Wiens, R. C. (2009) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2008.10.045 · Cited by 327
Self-citationMatrix Effects in the Detection of Pb and Ba in Soils Using Laser-Induced Breakdown Spectroscopy
Eppler, A. S., Cremers, D. A., Hickmott, D. D., Ferris, M. J., & Koskelo, A. C. (1996) · Applied Spectroscopy · doi:10.1366/0003702963905123 · Cited by 298
Sallé, B., Lacour, J.-L., Mauchien, P., Fichet, P., Maurice, S., & Manhès, G. (2006) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2006.02.003 · Cited by 238
Self-citationSirven, J.-B., Bousquet, B., Canioni, L., & Sarger, L. (2006) · Analytical Chemistry · doi:10.1021/ac051721p · Cited by 196
Sallé, B., Lacour, J.-L., Vors, E., Fichet, P., Maurice, S., Cremers, D. A., & Wiens, R. C. (2004) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2004.06.006 · Cited by 187
Self-citationPichavant, M., Kontak, D. J., Briqueu, L., Herrera, J. V., & Clark, A. H. (1988) · Contributions to Mineralogy and Petrology · doi:10.1007/bf00379742 · Cited by 174
Dudragne, L., Adam, P., & Amouroux, J. (1998) · Applied Spectroscopy · doi:10.1366/0003702981942654 · Cited by 167
Dyar, M. D., Tucker, J., Humphries, S. D., Clegg, S. M., Wiens, R. C., & Lane, M. D. (2010) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2010.11.016 · Cited by 136
Self-citationCalibration of the Mars Science Laboratory Alpha Particle X-ray Spectrometer
Campbell, J. L., Perrett, G. M., Gellert, R., Andrushenko, S. M., Boyd, N. I., Maxwell, J. A., King, P. L., & Schofield, C. D. M. (2012) · Space Science Reviews · doi:10.1007/s11214-012-9873-5 · Cited by 132
Optimization of laser-induced breakdown spectroscopy for rapid geochemical analysis
Tucker, J., Dyar, M. D., Schaefer, M. W., Clegg, S. M., & Wiens, R. C. (2010) · Chemical Geology · doi:10.1016/j.chemgeo.2010.07.016 · Cited by 126
Self-citationPichavant, M., Kontak, D. J., Valencia, J., & Clark, A. H. (1988) · Contributions to Mineralogy and Petrology · doi:10.1007/bf00379741 · Cited by 125
Fabre, C., Maurice, S., Cousin, A., Wiens, R. C., Forni, O., Sautter, V., & Guillaume, D. (2011) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2011.03.012 · Cited by 115
Self-citationRemote laser‐induced breakdown spectroscopy (LIBS) for lunar exploration
Lasue, J., Wiens, R. C., Clegg, S. M., Vaniman, D. T., Joy, K. H., Humphries, S. D., Mezzacappa, A., Melikechi, N., McInroy, R. E., & Bender, S. (2011) · Journal of Geophysical Research Atmospheres · doi:10.1029/2011je003898 · Cited by 106
Self-citationAnderson, R. B., Morris, R. V., Clegg, S. M., Bell, J. F., III, Wiens, R. C., Humphries, S. D., Mertzman, S. A., Graff, T. G., & McInroy, R. E. (2011) · Icarus · doi:10.1016/j.icarus.2011.07.034 · Cited by 98
Self-citationBrennetot, R., Lacour, J.-L., Vors, E., Rivoallan, A., Vailhen, D., & Maurice, S. (2003) · Applied Spectroscopy · doi:10.1366/000370203322102816 · Cited by 86
Self-citationDell’Aglio, M., Giacomo, A. D., Gaudiuso, R., Pascale, O. D., Senesi, N., & Longo, S. (2010) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2010.09.018 · Cited by 75
Ceramic ChemCam Calibration Targets on Mars Science Laboratory
Vaniman, D. T., Dyar, M. D., Wiens, R. C., Ollila, A., Lanza, N., Lasue, J., Rhodes, J. M., Clegg, S. M., & NEWSOM, H. E. (2012) · Space Science Reviews · doi:10.1007/s11214-012-9886-0 · Cited by 72
Self-citationDetermination of Sulfur Content in Steel by Laser-Produced Plasma Atomic Emission Spectroscopy
Gonzcález, A., Ortiz, M. C. R., & Campos, J. (1995) · Applied Spectroscopy · doi:10.1366/0003702953965768 · Cited by 71
Anderson, R. B., Bell, J. F., III, Wiens, R. C., Morris, R. V., & Clegg, S. M. (2012) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2012.04.004 · Cited by 52
Self-citationBricklemyer, R. S., Brown, D. J., Barefield, J. E., & Clegg, S. M. (2011) · Soil Science Society of America Journal · doi:10.2136/sssaj2009.0244 · Cited by 47
Self-citationTextural and modal analyses of picritic basalts with ChemCam Laser‐Induced Breakdown Spectroscopy
Cousin, A., Sautter, V., Fabre, C., Maurice, S., & Wiens, R. C. (2012) · Journal of Geophysical Research Atmospheres · doi:10.1029/2012je004132 · Cited by 26
Self-citationCampbell, J. L., McDonald, A. M., Perrett, G. M., & Taylor, S. (2010) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2010.09.014 · Cited by 23
Gan, W. S. (2020) · Springer eBooks · doi:10.1007/978-981-10-5550-8_8 · Cited by 19
Jochum, K. P., Enzweiler, J., Mertz‐Kraus, R., & Xiao-hong, W. (2010) · Geostandards and Geoanalytical Research · doi:10.1111/j.1751-908x.2010.00931.x · Cited by 15
Geology of the Elizabethtown and Port Henry quadrangles
Kemp, J. F., & Ruedemann, R. (1910) · University of the State of New York eBooks · Cited by 13
Ollila, A., Blank, J. G., Wiens, R. C., Lasue, J., NEWSOM, H. E., Clegg, S. M., Cousin, A., & Maurice, S. (2011) · Lunar and Planetary Science Conference · Cited by 10
Self-citation
Cited by
Martian Fluvial Conglomerates at Gale Crater
Williams, R. M. E., Grotzinger, J. P., Dietrich, W. E., Gupta, S., Sumner, D. Y., Wiens, R. C., Mangold, N., Malin, M. C., Edgett, K. S., Maurice, S., et al. (2013) · Science · doi:10.1126/science.1237317 · Cited by 381
Self-citationThe SuperCam Instrument Suite on the NASA Mars 2020 Rover: Body Unit and Combined System Tests
Wiens, R. C., Maurice, S., Robinson, S. H., Nelson, A. E., Cais, P., Bernardi, P., Newell, R. T., Clegg, S., Sharma, S. K., Storms, S., et al. (2021) · Space Science Reviews · doi:10.1007/s11214-020-00777-5 · Cited by 337
Self-citationIn situ evidence for continental crust on early Mars
Sautter, V., Toplis, M. J., Wiens, R. C., Cousin, A., Fabre, C., Gasnault, O., Maurice, S., Forni, O., Lasue, J., Ollila, A., et al. (2015) · Nature Geoscience · doi:10.1038/ngeo2474 · Cited by 319
Self-citationGood practices in LIBS analysis: Review and advices
El Haddad, J., Canioni, L., & Bousquet, B. (2014) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2014.08.039 · Cited by 307
Elemental Geochemistry of Sedimentary Rocks at Yellowknife Bay, Gale Crater, Mars
McLennan, S. M., Anderson, R. B., Bell, J. F., Bridges, J. C., Calef, F., Campbell, J. L., Clark, B. C., Clegg, S., Conrad, P., Cousin, A., et al. (2014) · Science · doi:10.1126/science.1244734 · Cited by 306
Self-citation
Metadata
- Authors
- Wiens, R. C., Maurice, S., Lasue, J., Forni, O., Anderson, R. B., Clegg, S., Bender, S., Blaney, D., Barraclough, B. L., Cousin, A., Deflores, L., Delapp, D., Dyar, M. D., Fabre, C., Gasnault, O., Lanza, N., Mazoyer, J., Melikechi, N., Meslin, P.-Y., Newsom, H., Ollila, A., Perez, R., Tokar, R. L., & Vaniman, D.
- Venue
- Spectrochimica Acta Part B: Atomic Spectroscopy
- Publisher
- Elsevier BV
- Published
- 2013-04
- Volume
- 82
- Pages
- 1-27
- ISSN
- 0584-8547 (ISSN-L)
- OpenAlex
- W2082289296
- Cited by
- 328
- References
- 46
- FWCI
- 30.71
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.