Ultrasound assisted deep eutectic solvent based microextraction-slotted quartz tube-flame atomic absorption spectrometry for the determination of cadmium
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
This study made use of the unique extraction properties of deep eutectic solvents (DESs) to determine trace levels of cadmium by slotted quartz tube flame atomic absorption spectrometry (SQT-FAAS). Ultrasound assisted (UA)-DES was applied in this study to improve the detection limit. The optimum extraction conditions were 1:2 ratio of choline chloride and phenol as DES, 0.50 mL DES volume, 1.0 mL emulsifier agent volume and 10 s of manual mixing. The linear calibration range of the optimum method was between 1.0 and 50 μg L−1. Combining the DES extraction method and SQT-FAAS gave 0.35 and 1.2 μg L− 1 as the limits of detection and quantitation (LOD and LOQ), respectively. The sensitivity was improved by about 80 folds when compared with the conventional FAAS system. Accuracy and applicability of the method were also checked using celery and apple samples, and the recovery results calculated were close to 100%, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Extraction techniques with deep eutectic solvents
Cunha, S. C., & Fernandes, J. O. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.05.001 · Cited by 760
Yilmaz, E., & Soylak, M. (2016) · Talanta · doi:10.1016/j.talanta.2016.08.001 · Cited by 177
Zounr, R. A., Tuzen, M., Deligonul, N., & Khuhawar, M. Y. (2018) · Food Chemistry · doi:10.1016/j.foodchem.2018.01.167 · Cited by 127
Dadfarnia, S., Haji Shabani, A. M., & Kamranzadeh, E. (2009) · Talanta · doi:10.1016/j.talanta.2009.02.004 · Cited by 97
Panhwar, A. H., Tuzen, M., & Kazi, T. G. (2018) · Talanta · doi:10.1016/j.talanta.2017.09.079 · Cited by 95
Li, X., Wang, M., Zhao, J., Guo, H., Gao, X., Xiong, Z., & Zhao, L. (2019) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2019.01.018 · Cited by 52
Cited by
Pacheco-Fernández, I., González-Martín, R., e Silva, F. A., Freire, M. G., & Pino, V. (2021) · Analytica Chimica Acta · doi:10.1016/j.aca.2020.08.022 · Cited by 69
“Abbreviations [C10Guþ] decylguanidinium [C4C4Imþ] dibutylimidazolium [C4Guþ] butylguanidinium [C4MImþ] butylmethylimidazolium [C5MImþ] pentylmethylimidazolium [Cholþ] cholinium [N4444þ ] tetrabutylammonium [Ni(BeIm)42þ] tetra(N-benzylimidazolium)nickelate(II) [Ni(C4Im)42þ] tetra(N-butylimidazolium)nickelate(II) [NTf2e…”
BackgroundMethodInfluentialElencovan, V., Joseph, J., Yahaya, N., Abdul Samad, N., Raoov, M., Lim, V., & Zain, N. N. M. (2022) · Food Chemistry · doi:10.1016/j.foodchem.2021.130835 · Cited by 53
Akramipour, R., Golpayegani, M. R., Ghasemi, M., Noori, N., & Fattahi, N. (2019) · New Journal of Chemistry · doi:10.1039/c9nj00979e · Cited by 44
Zhao, W., Jing, X., Tian, Y., & Feng, C. (2020) · Microchemical Journal · doi:10.1016/j.microc.2020.105416 · Cited by 43
Luján, C. E., Lemos, A. A., Oviedo, M. N., Llaver, M., & Wuilloud, R. G. (2024) · Talanta · doi:10.1016/j.talanta.2023.125451 · Cited by 21
Metadata
- Authors
- Unutkan, T., Tışlı, B., Tekin, Z., Çetin, G., & Bakırdere, S.
- Venue
- Spectrochimica Acta Part B: Atomic Spectroscopy
- Publisher
- Elsevier BV
- Published
- 2019-05
- Volume
- 155
- Pages
- 1-3
- ISSN
- 0584-8547 (ISSN-L)
- OpenAlex
- W2922019790
- Cited by
- 22
- References
- 6
- FWCI
- 2.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasound assisted deep eutectic solvent based microextraction-slotted quartz tube-flame atomic absorption spectrometry for the determination of cadmium. https://app.cochat.ai/papers/10.1016/j.sab.2019.03.001
- The paper
- Unutkan, T., Tışlı, B., Tekin, Z., Çetin, G., & Bakırdere, S. (2019). Ultrasound assisted deep eutectic solvent based microextraction-slotted quartz tube-flame atomic absorption spectrometry for the determination of cadmium. Spectrochimica Acta Part B: Atomic Spectroscopy. https://doi.org/10.1016/j.sab.2019.03.001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.