CryoEM maps are full of potential
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Electron microscopy is based on elastic scattering due to Coulomb forces between the incident electrons and the sample; thus, electron scattering is dependent on the charge distribution in the sample. Unlike atomic scattering factors for X-rays, electron scattering factors for some atoms are strongly dependent on scattering angle, and the scattering factor for ionic oxygen is negative at low scattering angle. This phenomenon can result in a significant negative contribution to Coulomb potential maps by oxygen and can result in deviations in the positions of positive map features from atomic centers. An important factor that can also complicate the interpretation of cryoEM maps is the exquisite sensitivity of macromolecules to damage from electron irradiation, especially the carboxylates of acidic amino acids. Ideally, when compared with electron density maps derived by X-ray crystallography, Coulomb potential maps can provide additional details about the electrostatic environment and charge state of atoms. Enhancements in model building, refinement and computational simulation will be required to realize the full potential of EM-derived maps to reveal deeper insight into the electronic structure and functional properties of macromolecular complexes and their interactions with binding partners, ligands, cofactors and drugs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
EMRinger: side chain–directed model and map validation for 3D cryo-electron microscopy
Barad, B. A., Echols, N., Wang, R. Y.-R., Cheng, Y., DiMaio, F., Adams, P. D., & Fraser, J. S. (2015) · Nature Methods · doi:10.1038/nmeth.3541 · Cited by 886
Electron crystallography of ultrathin 3D protein crystals: atomic model with charges
Yonekura, K., Kato, K., Ogasawara, M., Tomita, M., & Toyoshima, C. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1500724112 · Cited by 190 · cited 3×
“These effects were also noted by the Toyoshima group in their MicroED analysis of catalase microcrystals (see Figure 1 of [14]).”
BackgroundInfluential
Cited by
Improvement of cryo-EM maps by density modification
Terwilliger, T. C., Ludtke, S. J., Read, R. J., Adams, P. D., & Afonine, P. V. (2020) · Nature Methods · doi:10.1038/s41592-020-0914-9 · Cited by 288
Structure of the bacterial ribosome at 2 Å resolution
Watson, Z. L., Ward, F. R., Méheust, R., Ad, O., Schepartz, A., Banfield, J. F., & Cate, J. H. (2020) · eLife · doi:10.7554/elife.60482 · Cited by 263
Direct calculation of cryo-EM and crystallographic model maps for real-space refinement
Urzhumtsev, A. G., Urzhumtseva, L. M., & Lunin, V. Y. (2022) · Acta Crystallographica Section D Structural Biology · doi:10.1107/s2059798322010907 · Cited by 9
Ligand identification in CryoEM and X-ray maps using deep learning
Karolczak, J., Przybyłowska, A., Szewczyk, K., Taisner, W., Heumann, J. M., Stowell, M. H. B., Nowicki, M., & Brzezinski, D. (2024) · Bioinformatics · doi:10.1093/bioinformatics/btae749 · Cited by 7
Borges, R. J., Salvador, G. H. M., Pimenta, D. C., dos Santos, L. D., Fontes, M. R. M., & Usón, I. (2022) · Nucleic Acids Research · doi:10.1093/nar/gkac029 · Cited by 5
Metadata
- Authors
- Marques, M. A., Purdy, M. D., & Yeager, M.
- Venue
- Current Opinion in Structural Biology
- Publisher
- Elsevier BV
- Published
- 2019-10
- Volume
- 58
- Pages
- 214-223
- ISSN
- 0959-440X (ISSN-L)
- OpenAlex
- W2965703627
- Cited by
- 66
- References
- 2
- FWCI
- 0.75
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CryoEM maps are full of potential. https://app.cochat.ai/papers/10.1016/j.sbi.2019.04.006
- The paper
- Marques, M. A., Purdy, M. D., & Yeager, M. (2019). CryoEM maps are full of potential. Current Opinion in Structural Biology. https://doi.org/10.1016/j.sbi.2019.04.006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.