The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Iontronic pressure sensor with high sensitivity and linear response over a wide pressure range based on soft micropillared electrodes
Abstract
Electronic skins and flexible pressure sensors are important devices for advanced healthcare and intelligent robotics. Sensitivity is a key parameter of flexible pressure sensors. Whereas introducing surface microstructures in a capacitive-type sensor can significantly improve its sensitivity, the signal becomes nonlinear and the pressure response range gets much narrower, significantly limiting the applications of flexible pressure sensors. Here, we designed a pressure sensor that utilizes a nanoscale iontronic interface of an ionic gel layer and a micropillared electrode, for highly linear capacitance-to-pressure response and high sensitivity over a wide pressure range. The micropillars undergo three stages of deformation upon loading: initial contact (0-6 kPa) and structure buckling (6-12 kPa) that exhibit a low and nonlinear response, as well as a post-buckling stage that has a high signal linearity with high sensitivity (33.16 kPa-1) over a broad pressure range of 12-176 kPa. The high linearity lies in the subtle balance between the structure compression and mechanical matching of the two materials at the gel-electrode interface. Our sensor has been applied in pulse detection, plantar pressure mapping, and grasp task of an artificial limb. This work provides a physical insight in achieving linear response through the design of appropriate microstructures and selection of materials with suitable modulus in flexible pressure sensors, which are potentially useful in intelligent robots and health monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396 · cited 1×
“…human-machine interfaces, and internet of things, high-performance flexible tactile sensors or electronic skins have gained increasing attention [1–3], and have been reported to be potentially useful in application scenarios such as tactile perception for robots [4], and pulse wave detection…”
Coding and use of tactile signals from the fingertips in object manipulation tasks
Johansson, R. S., & Flanagan, J. R. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2621 · Cited by 2,063
Advances of flexible pressure sensors toward artificial intelligence and health care applications
Zang, Y., Zhang, F., Di, C.-A., & Zhu, D. (2015) · Materials Horizons · doi:10.1039/c4mh00147h · Cited by 1,272
User-interactive electronic skin for instantaneous pressure visualization
Wang, C., Hwang, D., Yu, Z., Takei, K., Park, J., Chen, T., Ma, B., & Javey, A. (2013) · Nature Materials · doi:10.1038/nmat3711 · Cited by 1,182
Gait Analysis Using Wearable Sensors
Tao, W., Liu, T., Zheng, R., & Feng, H. (2012) · Sensors · doi:10.3390/s120202255 · Cited by 1,165
Conductive Fiber‐Based Ultrasensitive Textile Pressure Sensor for Wearable Electronics
Lee, J., Kwon, H., Seo, J., Shin, S., Koo, J. H., Pang, C., Son, S., Kim, J. H., Jang, Y. H., Kim, D. E., et al. (2015) · Advanced Materials · doi:10.1002/adma.201500009 · Cited by 1,152
Recent Progress in Electronic Skin
Wang, X., Dong, L., Zhang, H., Yu, R., Pan, C., & Wang, Z. L. (2015) · Advanced Science · doi:10.1002/advs.201500169 · Cited by 976
A Sensitive and Biodegradable Pressure Sensor Array for Cardiovascular Monitoring
Boutry, C. M., Nguyen, A., Lawal, Q. O., Chortos, A., Rondeau‐Gagné, S., & Bao, Z. (2015) · Advanced Materials · doi:10.1002/adma.201502535 · Cited by 647
Emerging Technologies of Flexible Pressure Sensors: Materials, Modeling, Devices, and Manufacturing
Huang, Y., Fan, X., Chen, S., & Zhao, N. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201808509 · Cited by 543
Cited by
Shi, Z., Meng, L., Shi, X., Li, H., Zhang, J., Sun, Q., Liu, X., Chen, J., & Liu, S. (2022) · Nano-Micro Letters · doi:10.1007/s40820-022-00874-w · Cited by 282
Self-citationYuan, H., Zhang, Q., Zhou, T., Wu, W., Li, H., Yin, Z., Ma, J., & Jiao, T. (2024) · Chemical Engineering Journal · doi:10.1016/j.cej.2024.149926 · Cited by 180
Metadata
- Authors
- Lu, P., Wang, L., Zhu, P., Huang, J., Wang, Y., Bai, N., Wang, Y., Li, G., Yang, J., Xie, K., Zhang, J., Yu, B., Dai, Y., & Guo, C. F.
- Venue
- Science Bulletin
- Publisher
- Elsevier BV
- Published
- 2021-06
- Volume
- 66
- Issue
- 11
- Pages
- 1091-1100
- ISSN
- 2095-9273 (ISSN-L)
- OpenAlex
- W3128825830
- Cited by
- 268
- References
- 34
- FWCI
- 10.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Iontronic pressure sensor with high sensitivity and linear response over a wide pressure range based on soft micropillared electrodes. https://app.cochat.ai/papers/10.1016/j.scib.2021.02.019
- The paper
- Lu, P., Wang, L., Zhu, P., Huang, J., Wang, Y., Bai, N., Wang, Y., Li, G., Yang, J., Xie, K., Zhang, J., Yu, B., Dai, Y., & Guo, C. F. (2021). Iontronic pressure sensor with high sensitivity and linear response over a wide pressure range based on soft micropillared electrodes. Science Bulletin. https://doi.org/10.1016/j.scib.2021.02.019
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.