Cited by 180Advanced Sensor and Energy Harvesting MaterialsDielectric materials and actuatorsSensor Technology and Measurement Systems

Progress and challenges in flexible capacitive pressure sensors: Microstructure designs and applications

Open access
Yuan, Hao, Zhang, Qiran, Zhou, Tong, Wu, Wenbo, Li, Haoran, Yin, Zhuopeng, Ma, Jinming, Jiao, Tifeng·2024·Chemical Engineering Journal

Integrity signals

Registry

Crossref · 10.1016/j.cej.2024.149926

Cites

140 of 140 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Under external forces, changes in internal crystal structure, electron distribution, or the shape and structure of the dielectric layer induce capacitance variations that correlate with applied pressure in capacitive perovskite mechanical sensors.

    “Under external forces, changes in the internal crystal structure, electron distribution, or the shape and structure of the dielectric layer induce capacitance variations that correlate with the applied pressure [61].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Yuan, H., Zhang, Q., Zhou, T., Wu, W., Li, H., Yin, Z., Ma, J., & Jiao, T.
Affiliations
Yanshan University (CN)
Corresponding author
  • Ma, Jinming
  • Jiao, Tifeng
Venue
Chemical Engineering Journal
Publisher
Elsevier BV
Published
2024-04
Volume
485
Pages
149926
ISSN
1385-8947 (ISSN-L)
OpenAlex
W4392112513
Cited by
180
References
140
Citations by year
2026: 77 · 2025: 73 · 2024: 30
FWCI
18.92
Type
journal article
Language
en
Open access
Locations
Chemical Engineering Journal (acceptedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Biomedical Engineering › Dielectric materials and actuators
  • Physical Sciences › Computer Science › Computer Networks and Communications › Sensor Technology and Measurement Systems
Keywords
capacitive pressure sensor, flexible electronics, microstructure design, dielectric layer, electrode design, sensitivity, linearity, response and recovery time, bioelectronics, soft robotics, health monitoring

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review