Complications of vagal nerve stimulation for drug-resistant epilepsy
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
PURPOSE To longitudinally study surgical and hardware complications to vagal nerve stimulation (VNS) treatment in patients with drug-resistant epilepsy. METHODS In a longitudinal retrospective study, we analyzed surgical and hardware complications in 143 patients (81 men and 62 women) who between 1994 and 2010 underwent implantation of a VNS-device for drug-resistant epilepsy. The mean follow-up time was 62 ± 46 months and the total number of patient years 738. RESULTS 251 procedures were performed on 143 patients. 16.8% of the patients were afflicted by complications related to surgery and 16.8% suffered from hardware malfunctions. Surgical complications were: superficial infection in 3.5%, deep infection needing explantation in 3.5%, vocal cord palsy in 5.6%, which persisted in at least 0.7% for over one year, and other complications in 5.6%. Hardware-related complications were: lead fracture in 11.9% of patients, disconnection in 2.8%, spontaneous turn-off in 1.4% and stimulator malfunction in 1.4%. We noted a tendency to different survival times between the two most commonly used lead models as well as a tendency to increased infection rate with increasing number of stimulator replacements. CONCLUSION In this series we report on surgical and hardware complications from our 16 years of experience with VNS treatment. Infection following insertion of the VNS device and vocal cord palsy due to damage to the vagus nerve are the most serious complications related to the surgery. Avoiding unnecessary reoperations in order to reduce the appearances of these complications are of great importance. It is therefore essential to minimize technical malfunctions that will lead to additional surgery. Further studies are needed to evaluate the possible superiority of the modified leads.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Early Identification of Refractory Epilepsy
Kwan, P., & Brodie, M. J. (2000) · New England Journal of Medicine · doi:10.1056/nejm200002033420503 · Cited by 5,204
Vagus-nerve stimulation for the treatment of epilepsy
Ben-Menachem, E. (2002) · The Lancet Neurology · doi:10.1016/s1474-4422(02)00220-x · Cited by 560
Rydenhag, B., & Silander, H. C. (2001) · Neurosurgery · doi:10.1097/00006123-200107000-00007 · Cited by 177
Cited by
Dawson, J., Liu, C. Y., Francisco, G. E., Cramer, S. C., Wolf, S. L., Dixit, A., Alexander, J., Ali, R., Brown, B. L., Feng, W., et al. (2021) · The Lancet · doi:10.1016/s0140-6736(21)00475-x · Cited by 518
Nine-year prospective efficacy and safety of brain-responsive neurostimulation for focal epilepsy
Nair, D. R., Laxer, K. D., Weber, P. B., Murro, A. M., Park, Y. D., Barkley, G. L., Smith, B. J., Gwinn, R. P., Doherty, M. J., Noe, K. H., et al. (2020) · Neurology · doi:10.1212/wnl.0000000000010154 · Cited by 490
Toffa, D. H., Touma, L., El Meskine, T., Bouthillier, A., & Nguyen, D. K. (2020) · Seizure · doi:10.1016/j.seizure.2020.09.027 · Cited by 286
Vagus nerve stimulation: Surgical technique of implantation and revision and related morbidity
Giordano, F., Zicca, A., Barba, C., Guerrini, R., & Genitori, L. (2017) · Epilepsia · doi:10.1111/epi.13678 · Cited by 258
“Anyway, only a few patients manifested a permanent vocal cord palsy (<1%).(37,49) In the series by Ng, eight patients underwent lead revision through ultrasharp low-voltage cautery coupled with blunt dissection without any damage to the vagus nerve and any related complication.”
BackgroundHuman vagus nerve branching in the cervical region.
Hammer, N., Glätzner, J., Feja, C., Kühne, C., Meixensberger, J., Planitzer, U., Schleifenbaum, S., Tillmann, B. N., & Winkler, D. (2015) · PLOS ONE · doi:10.1371/journal.pone.0118006 · Cited by 88
“Undesirable side effects such as voice alterations, dyspnea [6,9,16], vocal cord palsy [16], neck and throat pain and coughing have been described in 17% of the patients treated with VNS [6].”
Background
Metadata
- Authors
- Kahlow, H., & Olivecrona, M.
- Venue
- Seizure
- Publisher
- Elsevier BV
- Published
- 2013-12
- Volume
- 22
- Issue
- 10
- Pages
- 827-833
- ISSN
- 1059-1311 (ISSN-L)
- OpenAlex
- W1761916815
- Cited by
- 132
- References
- 3
- FWCI
- 3.37
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Complications of vagal nerve stimulation for drug-resistant epilepsy. https://app.cochat.ai/papers/10.1016/j.seizure.2013.06.011
- The paper
- Kahlow, H., & Olivecrona, M. (2013). Complications of vagal nerve stimulation for drug-resistant epilepsy. Seizure. https://doi.org/10.1016/j.seizure.2013.06.011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.