The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Flexible polymeric dry electrodes for the long-term monitoring of ECG
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A direct comparison of wet, dry and insulating bioelectric recording electrodes
Searle, A., & Kirkup, L. (2000) · Physiological Measurement · doi:10.1088/0967-3334/21/2/307 · Cited by 725
Diffusion of Gases in Silicone Polymers: Molecular Dynamics Simulations
Charati, S. G., & Stern, S. A. (1998) · Macromolecules · doi:10.1021/ma980387e · Cited by 423
Cellular Micropatterns on Biocompatible Materials
Folch, A., & Toner, M. (1998) · Biotechnology Progress · doi:10.1021/bp980037b · Cited by 270
Sias, F. R. (1961) · Science · doi:10.1126/science.134.3495.2055 · Cited by 179
A dry electrophysiology electrode using CNT arrays
Ruffini, G., Dunne, S., Farrés, E., Marco‐Pallarés, J., Ray, C., Mendoza, E., Silva, S. R. P., & Grau, C. (2006) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2006.06.013 · Cited by 97
Fibre-Meshed Transducers Based Real Time Wearable Physiological Information Monitoring System
WIJESIRIWARDANA, R., Mitcham, K., & Dias, T. (2004) · International Symposium on Wearable Computers · doi:10.1109/iswc.2004.20 · Cited by 65
Mobile patient monitoring based on impedance-loaded SAW-sensors
Karilainen, A. O., Finnberg, T., Uelzen, T., Dembowski, K., & Müller, J. W. (2004) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1367487 · Cited by 30
Ambulatory cardiopulmonary data capture
Coyle, M. (2003) · International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology (MMB) · doi:10.1109/mmb.2002.1002333 · Cited by 23
New technologies for in-flight pasteless bioelectrodes.
Prutchi, D., & Sagi-Dolev, A. (1993) · PubMed · Cited by 2
Cited by
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Multifunctional Epidermal Electronics Printed Directly Onto the Skin
Yeo, W., Kim, Y., Lee, J., Ameen, A., Shi, L., Li, M., Wang, S., Ma, R., Jin, S. H., Kang, Z., et al. (2013) · Advanced Materials · doi:10.1002/adma.201204426 · Cited by 828
Flexible and Stretchable Electronics for Biointegrated Devices
Kim, D.-H., Ghaffari, R., Lu, N., & Rogers, J. A. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150018 · Cited by 749
Nanomaterial‐Enabled Stretchable Conductors: Strategies, Materials and Devices
Yao, S., & Zhu, Y. (2015) · Advanced Materials · doi:10.1002/adma.201404446 · Cited by 695
CNT/PDMS Composite Flexible Dry Electrodesfor Long-Term ECG Monitoring
Jung, H.-C., Moon, J.-H., Baek, D.-H., Lee, J.-H., Choi, Y.-Y., Hong, J.-S., & Lee, S.-H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2190288 · Cited by 434
Self-citation
Metadata
- Authors
- Baek, J.-Y., An, J.-H., Choi, J.-M., Park, K.-S., & Lee, S.-H.
- Venue
- Sensors and Actuators A: Physical
- Publisher
- Elsevier BV
- Published
- 2008-05
- Volume
- 143
- Issue
- 2
- Pages
- 423-429
- ISSN
- 0924-4247 (ISSN-L)
- OpenAlex
- W2039115600
- Cited by
- 340
- References
- 9
- FWCI
- 3.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flexible polymeric dry electrodes for the long-term monitoring of ECG. https://app.cochat.ai/papers/10.1016/j.sna.2007.11.019
- The paper
- Baek, J.-Y., An, J.-H., Choi, J.-M., Park, K.-S., & Lee, S.-H. (2008). Flexible polymeric dry electrodes for the long-term monitoring of ECG. Sensors and Actuators A: Physical. https://doi.org/10.1016/j.sna.2007.11.019
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.