CNT/PDMS Composite Flexible Dry Electrodesfor Long-Term ECG Monitoring

Ha-Chul Jung, Jin-Hee Moon, Dong-Hyun Baek, Jae-Hee Lee, Yoon-Young Choi, Joung-Sook Hong, Sang-Hoon Lee·2012·IEEE Transactions on Biomedical Engineering

Abstract

We fabricated a carbon nanotube (CNT)/ polydimethylsiloxane (PDMS) composite-based dry ECG electrode that can be readily connected to conventional ECG devices, and showed its long-term wearable monitoring capability and robustness to motion and sweat. While the dispersion of CNTs in PDMS is challenging, we optimized the process to disperse untreated CNTs within PDMS by mechanical force only. The electrical and mechanical characteristics of the CNT/PDMS electrode were tested according to the concentration of CNTs and its thickness. The performances of ECG electrodes were evaluated by using 36 types of electrodes which were fabricated with different concentrations of CNTs, and with a differing diameter and thickness. The ECG signals were obtained by using electrodes of diverse sizes to observe the effects of motion and sweat, and the proposed electrode was shown to be robust to both factors. The CNT concentration and diameter of the electrodes were critical parameters in obtaining high-quality ECG signals. The electrode was shown to be biocompatible from the cytotoxicity test. A seven-day continuous wearability test showed that the quality of the ECG signal did not degrade over time, and skin reactions such as itching or erythema were not observed. This electrode could be used for the long-term measurement of other electrical biosignals for ubiquitous health monitoring including EMG, EEG, and ERG.

Integrity signals

Registry

Crossref · 10.1109/tbme.2012.2190288

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The high viability (exceeding 95%) of skin fibroblast cells and negligible side effects on examinees confirmed the good biocompatibility of CNT/PDMS dry electrodes.

    “The high viability (exceeding 95%) of the skin fibroblast cells and negligible side effects on examinees confirmed the good biocompatibility of CNT/PDMS dry electrodes.”

    From Nanomaterial-Enabled Wearable Sensors for Healthcare (2018) · cites this paper as [94]

  • Only preliminary experiments were performed on biocompatibility of nanomaterials for wearable applications.

    “For example, only preliminary experiments were performed on biocompatibility of nanomaterials for wearable applications.[94,95,205]”

    From Nanomaterial-Enabled Wearable Sensors for Healthcare (2018) · cites this paper as [94]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Jung, H.-C., Moon, J.-H., Baek, D.-H., Lee, J.-H., Choi, Y.-Y., Hong, J.-S., & Lee, S.-H.
Affiliations
  • Korea University (KR)
  • Soongsil University (KR)
Venue
IEEE Transactions on Biomedical Engineering
Published
2012-05
Volume
59
Issue
5
Pages
1472-1479
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2140236254
Cited by
434
References
32
Citations by year
2026: 16 · 2025: 21 · 2024: 37 · 2023: 30 · 2022: 36 · 2021: 40 · 2020: 55 · 2019: 53 · 2018: 34 · 2017: 26 · 2016: 24 · 2015: 28 · 2014: 24 · 2013: 8 · 2012: 2
FWCI
11.29
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
Keywords
flexible electrodes, CNT dispersion, motion robustness, biocompatibility, cytotoxicity, skin reactions, ubiquitous health monitoring, electromyography, EEG, ERG
MeSH terms
Adult, Clothing, Dimethylpolysiloxanes, Electrocardiography, Electrodes, Female, Humans, Male, Materials Testing, Monitoring, Ambulatory, Nanotubes, Carbon

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review