The DOI matches its Crossref record.
Diffusion of Gases in Silicone Polymers: Molecular Dynamics Simulations
Abstract
Diffusion coefficients of He, O 2, N 2, CO 2, and CH 4 at 300 K in four silicone polymers, namely, poly(dimethylsiloxane) (PDMS), poly(propylmethylsiloxane), poly((trifluoropropyl)methylsiloxane), and poly(phenylmethylsiloxane), have been estimated by molecular dynamics (MD) simulations. The estimated diffusion coefficients decrease with increasing size of the polymer side chains and of the penetrant molecules, as was also found experimentally. The estimated diffusion coefficient for He in PDMS is consistent with its experimental value. The values of the estimated diffusion coefficients for the other gas/silicone systems considered in this study are within ± 40−60% of the corresponding experimental values. The MD simulations revealed two types of motions of the penetrant molecules: (1) “jumps” from one cavity in a silicone matrix to another, and (2) “oscillating motions” inside cavities. The lengths of the jumps are of the order of 8−15 Å, whereas the oscillating motions are of the order of ≤5 Å. The total timeframe for the execution of a jump is about 5 ps (5 × 10 -12 s). The number of jumps and the average length of a jump of a penetrant molecule inside a silicone matrix decrease as the size of the molecule and of the polymer side chain increase. Some problems associated with the estimation of gas diffusion coefficients in polymers by MD simulations are also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Continuous perfusion microfluidic cell culture array for high‐throughput cell‐based assays
Hung, P. J., Lee, P. J., Sabounchi, P., Lin, R., & Lee, L. P. (2005) · Biotechnology and Bioengineering · doi:10.1002/bit.20289 · Cited by 522
3D Printing PDMS Elastomer in a Hydrophilic Support Bath via Freeform Reversible Embedding
Hinton, T. J., Hudson, A., Pusch, K., Lee, A., & Feinberg, A. W. (2016) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.6b00170 · Cited by 437
CNT/PDMS Composite Flexible Dry Electrodesfor Long-Term ECG Monitoring
Jung, H.-C., Moon, J.-H., Baek, D.-H., Lee, J.-H., Choi, Y.-Y., Hong, J.-S., & Lee, S.-H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2190288 · Cited by 434
Cell Culture in 3-Dimensional Microfluidic Structure of PDMS (polydimethylsiloxane)
Leclerc, E., Sakai, Y., & Fujii, T. (2003) · Biomedical Microdevices · doi:10.1023/a:1024583026925 · Cited by 324
Oxygen control with microfluidics
Brennan, M. D., Rexius-Hall, M. L., Elgass, L. J., & Eddington, D. T. (2014) · Lab Chip · doi:10.1039/c4lc00853g · Cited by 188
Metadata
- Authors
- Charati, S. G., & Stern, S. A.
- Venue
- Macromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-07-28
- Volume
- 31
- Issue
- 16
- Pages
- 5529-5535
- ISSN
- 0024-9297 (ISSN-L)
- 1520-5835
- OpenAlex
- W2052234083
- Cited by
- 423
- References
- 0
- FWCI
- 7.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diffusion of Gases in Silicone Polymers: Molecular Dynamics Simulations. https://app.cochat.ai/papers/10.1021/ma980387e
- The paper
- Charati, S. G., & Stern, S. A. (1998). Diffusion of Gases in Silicone Polymers: Molecular Dynamics Simulations. Macromolecules. https://doi.org/10.1021/ma980387e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.