Non-invasive intraocular pressure monitoring with a contact lens engineered with a nanostructured polymeric sensing film
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Contact lenses have been functionalized with electronics and photonic crystals to report on the concentrations of analytes in tear fluid.
“Contact lenses have been functionalized with electronics and photonic crystals to report on the concentrations of analytes in tear fluid.59”
From Wearables in Medicine (2018) · cites this paper as [59]
Cites
First steps toward noninvasive intraocular pressure monitoring with a sensing contact lens
Leonardi, M., Leuenberger, P., Bertrand, D., Bertsch, A., & Renaud, P. (2004) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-0015 · Cited by 244 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Yetisen, A. K., Martinez‐Hurtado, J. L., Ünal, B., Khademhosseini, A., & Butt, H. (2018) · Advanced Materials · doi:10.1002/adma.201706910 · Cited by 569 · see citing works
Contact Lens Sensors in Ocular Diagnostics
Farandos, N. M., Yetisen, A. K., Monteiro, M. J., Lowe, C. R., & Yun, S. H. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400504 · Cited by 466 · see citing works
- Authors
- Laukhin, V., Sánchez, I., Moya, A., Laukhina, E., Martin, R., Ussa, F., Rovira, C., Guimera, A., Villa, R., Aguiló, J., Pastor, J.-C., & Veciana, J.
- Affiliations
- Institució Catalana de Recerca i Estudis Avançats (ES)
- Universidad de Valladolid (ES)
- Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (ES)
- Consejo Superior de Investigaciones Científicas (ES)
- Corresponding author
- Laukhin, Vladimir
- Veciana, Jaume
- Venue
- Sensors and Actuators A: Physical
- Publisher
- Elsevier BV
- Published
- 2011-11
- Volume
- 170
- Issue
- 1-2
- Pages
- 36-43
- ISSN
- 0924-4247 (ISSN-L)
- OpenAlex
- W2059279230
- Cited by
- 57
- References
- 1
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 5 · 2023: 1 · 2022: 6 · 2021: 8 · 2020: 4 · 2019: 4 · 2018: 3 · 2017: 2 · 2016: 2 · 2015: 2 · 2014: 9 · 2013: 2 · 2012: 5
- FWCI
- 3.03
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Sensors and Actuators A Physical (publishedVersion)
- Funders
- Johns Hopkins University
- European Commission
- Generalitat de Catalunya
- Universitat de Barcelona
- Instituto de Salud Carlos III
- European Regional Development Fund
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Ocular Surface and Contact Lens
- Keywords
- intraocular pressure monitoring, contact lens sensor, piezoresistive sensors, corneal curvature, eye phantom, biocompatible sensors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review