First steps toward noninvasive intraocular pressure monitoring with a sensing contact lens
Open accessAbstract
PURPOSE: To present a novel and minimally invasive approach to intraocular pressure (IOP) monitoring based on a sensing contact lens. METHODS: The key element of this measurement method is a soft contact lens with an embedded microfabricated strain gauge allowing the measurement of changes in corneal curvature correlated to variations in IOP. A prototype of this sensing contact lens was adapted and tested on enucleated porcine eyes. To verify the measurement principle of the device, the posterior chamber of the pig eyes was cannulated and connected to a syringe pump and a pressure sensor for precise control of IOP. The measurements of the contact lens were then compared to the ones from the pressure sensor, while pressure variations were induced through the cannula. RESULTS: Enucleated porcine eyes were stimulated with increasing and decreasing ramps of IOP. Measurements from the sensing contact lens and from the pressure sensor showed very good correlation, proving the high potential of this new measurement principle. In this study, a typical signal from the sensing contact lens obtained during the experiments is presented and discussed. CONCLUSIONS: The sensing contact lens shows the potential for continuously monitoring IOP in enucleated porcine eyes. The ultimate step will be the validation of the system and the reproducibility of results in humans. The device is placed in the same way as a corrective contact lens, no anesthesia is required, and vision remains almost unimpaired. This device would allow minimally invasive IOP monitoring over prolonged periods, regardless of the patient's position and activity, thus opening up new diagnostic and therapeutic methods for the management of glaucoma.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The requirement for bulky and expensive equipment for signal measurements limits the use of smart contact lenses outside research laboratories or clinical settings by restricting users' external activities.
“(iv) the requirement for bulky and expensive equipment for signal measurements, which limits the use of smart contact lenses outside of research laboratories or clinical settings by restricting users’ external activities (14, 15, 20, 23).”
From Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays (2018) · cites this paper as [23]
Cites
Formulas for Stress and Strain
Roark, R. J., Young, W. C., & Plunkett, R. K. (1976) · Journal of Applied Mechanics · doi:10.1115/1.3423917 · Cited by 1,930 · see citing works
Asrani, S., Zeimer, R. C., Wilensky, J. T., Gieser, D. K., Vitale, S., & Lindenmuth, K. A. (2000) · Journal of Glaucoma · doi:10.1097/00061198-200004000-00002 · Cited by 902 · see citing works
Polyimides as biomaterials: preliminary biocompatibility testing
Richardson, R. R., Miller, J. A., & Reichert, W. M. (1993) · Biomaterials · doi:10.1016/0142-9612(93)90183-3 · Cited by 302 · see citing works
Miniature Passive Pressure Transensor for Implanting in the Eye
Collins, C. C. (1967) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1967.4502474 · Cited by 283 · see citing works
Diurnal Intraocular Pressure in Untreated Exfoliation and Primary Open-angle Glaucoma
Konstas, A. G. P. (1997) · Archives of Ophthalmology · doi:10.1001/archopht.1997.01100150184006 · Cited by 234 · see citing works
24-hour monitoring of intraocular pressure in glaucoma management: a retrospective review
Hughes, E. L., Spry, P., & Diamond, J. (2003) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2003.10.008 · Cited by 216 · see citing works
Polyimide-based microfluidic devices
Metz, S. W., Holzer, R., & Renaud, P. (2001) · Lab on a Chip · doi:10.1039/b103896f · Cited by 186 · see citing works
Self-citationIn vitro measurement of corneal strain, thickness, and curvature using digital image processing
Hjortdal, J., & Jensen, P. K. (1995) · Acta Ophthalmologica Scandinavica · doi:10.1111/j.1600-0420.1995.tb00004.x · Cited by 133 · see citing works
A soft contact lens with a MEMS strain gage embedded for intraocular pressure monitoring
Leonardi, M., Leuenberger, P., Bertrand, D., Bertsch, A., & Renaud, P. (2004) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.2003.1216947 · Cited by 81 · see citing works
Self-citationDevelopment of a Completely Encapsulated Intraocular Pressure Sensor
Walter, P., Schnakenberg, U., Bögel, G. V., Ruokonen, P., Krüger, C., Dinslage, S., LÜDTKE-HANDJERY, H.-C., Richter, H. A., Mokwa, W., Diestelhorst, M., et al. (2000) · Ophthalmic Research · doi:10.1159/000055626 · Cited by 67 · see citing works
Maurice, D. M. (1958) · British Journal of Ophthalmology · doi:10.1136/bjo.42.6.321 · Cited by 63 · see citing works
The effect of an artificially elevated intraocular pressure on the central corneal curvature
Lam, A. K. C. (1997) · Ophthalmic and Physiological Optics · doi:10.1016/s0275-5408(96)00033-6 · Cited by 63 · see citing works
Intraocular pressure measurement with instrumented contact lenses.
Greene, M. E., & Gilman, B. G. (1974) · PubMed · Cited by 53 · see citing works
Cooper, R. L., Beale, D. G., Constable, I. J., & Grose, G. C. (1979) · British Journal of Ophthalmology · doi:10.1136/bjo.63.12.799 · Cited by 42 · see citing works
Svedbergh, B., Bäcklund, Y., Hök, B., & Rosengren, L. (1992) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.1992.tb04135.x · Cited by 38 · see citing works
Rota‐Bartelink, A., Pitt, A., & Story, I. H. (1996) · Journal of Glaucoma · doi:10.1097/00061198-199612000-00009 · Cited by 35 · see citing works
A scleral buckle pressure gauge for continuous monitoring of intraocular pressure
Wolbarsht, M. L., Wortman, J. J., Schwartz, B., & Cook, D. (1980) · International Ophthalmology · doi:10.1007/bf00136208 · Cited by 32 · see citing works
An Analysis of the Physical Forces Applied to a Corneal Contact Lens
Miller, D. S. (1963) · Archives of Ophthalmology · doi:10.1001/archopht.1963.00960050825018 · Cited by 20 · see citing works
Passive telemetry by harmonics detection
Schuylenbergh, K. V., & Puers, R. (2002) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.1996.656962 · Cited by 20 · see citing works
Nissen, O. I. (1977) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.1977.tb08273.x · Cited by 16 · see citing works
A theoretical design for a contact lens tonometer
Lee, D. A. (1988) · Medical Hypotheses · doi:10.1016/0306-9877(88)90109-0 · Cited by 8 · see citing works
Flagged first, then by citations
1 of the 22 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics
Kim, J., Kim, M., Lee, M.-S., Kim, K., Ji, S., Kim, Y.-T., Park, J., Na, K., Bae, K.-H., Kyun Kim, H., et al. (2017) · Nature Communications · doi:10.1038/ncomms14997 · Cited by 951 · see citing works
Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays
Park, J., Kim, J., Kim, S.-Y., Cheong, W. H., Jang, J., Park, Y.-G., Na, K., Kim, Y.-T., Heo, J. H., Lee, C. Y., et al. (2018) · Science Advances · doi:10.1126/sciadv.aap9841 · Cited by 671 · see citing works
Sang, M., Shin, J., Kim, K., & Yu, K. J. (2019) · Nanomaterials · doi:10.3390/nano9030374 · Cited by 509 · see citing works
Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes
Leonardi, M., Pitchon, E. M., Bertsch, A., Renaud, P., & Mermoud, A. (2009) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.2008.01404.x · Cited by 300 · see citing works
Self-citationA soft and transparent contact lens for the wireless quantitative monitoring of intraocular pressure
Kim, J., Park, J., Park, Y.-G., Cha, E., Ku, M., An, H. S., Lee, K., Huh, M., Kim, T., Kim, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00719-8 · Cited by 233 · see citing works
Mansouri, K., & Shaarawy, T. M. (2011) · British Journal of Ophthalmology · doi:10.1136/bjo.2010.192922 · Cited by 230 · see citing works
Recent Advances in Transparent Electronics with Stretchable Forms
Kim, K., Park, Y., Hyun, B. G., Choi, M., & Park, J. (2018) · Advanced Materials · doi:10.1002/adma.201804690 · Cited by 223 · see citing works
Chronically implanted pressure sensors: challenges and state of the field
Yu, L., Kim, B., & Meng, E. (2014) · Sensors · doi:10.3390/s141120620 · Cited by 200 · see citing works
Continuous 24-Hour Monitoring of Intraocular Pressure Patterns With a Contact Lens Sensor
Mansouri, K., Medeiros, F. A., Tafreshi, A., & Weinreb, R. N. (2012) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2012.2280 · Cited by 180 · see citing works
Materials for microfabricated implantable devices: a review
Scholten, K., & Meng, E. F. (2015) · Lab on a Chip · doi:10.1039/c5lc00809c · Cited by 161 · see citing works
Recent Progress in Wireless Sensors for Wearable Electronics
Park, Y., Lee, S.-I., & Park, J. (2019) · Sensors · doi:10.3390/s19204353 · Cited by 161 · see citing works
Printing Flexible and Hybrid Electronics for Human Skin and Eye‐Interfaced Health Monitoring Systems
Kim, K., Kim, B., & Lee, C. H. (2019) · Advanced Materials · doi:10.1002/adma.201902051 · Cited by 146 · see citing works
Biomechanical analysis of the keratoconic cornea
Gefen, A., Shalom, R., Elad, D., & Mandel, Y. (2008) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2008.07.002 · Cited by 145 · see citing works
Agnifili, L., Mastropasqua, R., Frezzotti, P., Fasanella, V., Motolese, I., Pedrotti, E., Iorio, A. D., Mattei, P. A., Motolese, E., & Mastropasqua, L. (2014) · Acta Ophthalmologica · doi:10.1111/aos.12408 · Cited by 142 · see citing works
A Miniature-Implantable RF-Wireless Active Glaucoma Intraocular Pressure Monitor
Chow, E. Y., Chlebowski, A. L., & Irazoqui, P. P. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2081364 · Cited by 138 · see citing works
Lab‐on‐a‐Contact Lens: Recent Advances and Future Opportunities in Diagnostics and Therapeutics
Zhu, Y., Li, S., Li, J., Falcone, N., Cui, Q., Shah, S., Hartel, M. C., Yu, N., Young, P., de Barros, N. R., et al. (2022) · Advanced Materials · doi:10.1002/adma.202108389 · Cited by 123 · see citing works
Recent Advances in Smart Contact Lenses
Kim, J., Cha, E., & Park, J. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201900728 · Cited by 118 · see citing works
Xue, N., Chang, S., & Lee, J. (2012) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2012.2206072 · Cited by 110 · see citing works
Intraocular Pressure Monitoring Sensors
Katuri, K. C., Asrani, S., & Ramasubramanian, M. K. (2007) · IEEE Sensors Journal · doi:10.1109/jsen.2007.912539 · Cited by 108 · see citing works
Moraes, C. G. D., Jasien, J. V., Simon‐Zoula, S., Liebmann, J. M., & Ritch, R. H. (2016) · Ophthalmology · doi:10.1016/j.ophtha.2015.11.020 · Cited by 106 · see citing works
How to Measure Intraocular Pressure: An Updated Review of Various Tonometers
Brusini, P., Salvetat, M. L., & Zeppieri, M. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10173860 · Cited by 106 · see citing works
BCLA CLEAR – Contact lens technologies of the future
Jones, L., Hui, A., Phan, C., Read, M., Azar, D. T., Buch, J. R., Ciolino, J. B., Naroo, S. A., Pall, B., Romond, K., et al. (2021) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2021.02.007 · Cited by 100 · see citing works
Tear cytokines in acute and chronic ocular allergic inflammation
Cook, E. B. (2004) · Current Opinion in Allergy and Clinical Immunology · doi:10.1097/00130832-200410000-00018 · Cited by 98 · see citing works
Koutsonas, A., Walter, P., Roessler, G. F., & Plange, N. (2015) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.14-14925 · Cited by 96 · see citing works
Nanotechnology in ophthalmology
Zarbin, M. A., Montemagno, C. D., Leary, J. F., & Ritch, R. H. (2010) · Canadian Journal of Ophthalmology · doi:10.3129/i10-090 · Cited by 96 · see citing works
24-h monitoring devices and nyctohemeral rhythms of intraocular pressure
Aptel, F., Weinreb, R. N., Chiquet, C., & Mansouri, K. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.07.002 · Cited by 93 · see citing works
Mottet, B., Aptel, F., Romanet, J.-P., Hubanova, R., Pépin, J.-L., & Chiquet, C. (2013) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2013.5297 · Cited by 94 · see citing works
Smart Contact Lenses for Healthcare Monitoring and Therapy
Liu, X., Ye, Y., Ge, Y., Qu, J., Liedberg, B., Zhang, Q., & Wang, Y. (2024) · ACS Nano · doi:10.1021/acsnano.3c12072 · Cited by 89 · see citing works
Wearable and Implantable Intraocular Pressure Biosensors: Recent Progress and Future Prospects
Yang, C., Huang, X., Li, X., Yang, C., Zhang, T., Wu, Q., Liu, D., Lin, H., Chen, W., Hu, N., et al. (2021) · Advanced Science · doi:10.1002/advs.202002971 · Cited by 86 · see citing works
A microscale optical implant for continuous in vivo monitoring of intraocular pressure
Lee, J. O., Park, H., Du, J., Balakrishna, A., Chen, O., Sretavan, D. W., & Choo, H. (2017) · Microsystems & Nanoengineering · doi:10.1038/micronano.2017.57 · Cited by 88 · see citing works
An, H., Chen, L., Liu, X., Zhao, B., Zhang, H., & Wu, Z. (2019) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2019.04.050 · Cited by 88 · see citing works
Interleukin-6 inhibition in the management of non-infectious uveitis and beyond
Karkhur, S., Hasanreisoğlu, M., Vigil, E. M., Halim, M. S., Hassan, M., Plaza, C., Nguyen, N. V., Afridi, R., Tran, A. N. T., Diana, V., et al. (2019) · Journal of Ophthalmic Inflammation and Infection · doi:10.1186/s12348-019-0182-y · Cited by 84 · see citing works
Photonic crystal-based smart contact lens for continuous intraocular pressure monitoring
Maeng, B., Chang, H., & Park, J. (2020) · Lab on a Chip · doi:10.1039/c9lc01268k · Cited by 84 · see citing works
Xu, J., Cui, T., Hirtz, T., Qiao, Y., Li, X., Zhong, F., Han, X., Yang, Y., Zhang, S., & Ren, T. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c02991 · Cited by 82 · see citing works
Efficacy of a Contact Lens Sensor for Monitoring 24-H Intraocular Pressure Related Patterns
Mansouri, K., Weinreb, R. N., & Liu, J. H. K. (2015) · PLoS ONE · doi:10.1371/journal.pone.0125530 · Cited by 80 · see citing works
Moraes, C. G. D., Mansouri, K., Liebmann, J. M., & Ritch, R. H. (2018) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2018.1746 · Cited by 77 · see citing works
24-hour Intraocular Pressure Fluctuation Monitoring Using an Ocular Telemetry Sensor
Smedt, S. D., Mermoud, A., & Schnyder, C. C. (2011) · Journal of Glaucoma · doi:10.1097/ijg.0b013e31821dac43 · Cited by 76 · see citing works
Analysis of Continuous 24-Hour Intraocular Pressure Patterns in Glaucoma
Mansouri, K., Liu, J. H. K., Weinreb, R. N., Tafreshi, A., & Medeiros, F. A. (2012) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.12-10569 · Cited by 74 · see citing works
Konstas, A. G. P., Kahook, M. Y., Araie, M., Katsanos, A., Quaranta, L., Rossetti, L. M., Holló, G., Detorakis, Ε. T., Oddone, F., Mikropoulos, D. G., et al. (2018) · Advances in Therapy · doi:10.1007/s12325-018-0812-z · Cited by 74 · see citing works
Cavitas Sensors: Contact Lens Type Sensors & Mouthguard Sensors
Mitsubayashi, K., & Arakawa, T. (2016) · Electroanalysis · doi:10.1002/elan.201600083 · Cited by 71 · see citing works
Intraocular pressure variations: Causes and clinical significance
Sit, A. J. (2014) · Canadian Journal of Ophthalmology · doi:10.1016/j.jcjo.2014.07.008 · Cited by 69 · see citing works
Ophthalmic Sensors and Drug Delivery
Savariraj, A. D., Salih, A. E., Alam, F., Elsherif, M., AlQattan, B., Khan, A. A., Yetisen, A. K., & Butt, H. (2021) · ACS Sensors · doi:10.1021/acssensors.1c00370 · Cited by 68 · see citing works
Liu, W., Du, Z., Duan, Z., Li, L., & Shen, G. (2024) · Nature Communications · doi:10.1038/s41467-024-49907-5 · Cited by 68 · see citing works
Zhang, Y., Chen, Y., Man, T., Huang, D., Li, X., Zhu, H., & Li, Z. (2019) · Microsystems & Nanoengineering · doi:10.1038/s41378-019-0078-x · Cited by 67 · see citing works
Cheng, S., Gu, Z., Zhou, L., Hao, M., An, H., Song, K., Wu, X., Zhang, K., Zhao, Z., Dong, Y., et al. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.765987 · Cited by 64 · see citing works
Continuous Monitoring of Intraocular Pressure
Sit, A. J. (2009) · Journal of Glaucoma · doi:10.1097/ijg.0b013e3181862490 · Cited by 64 · see citing works
Wearable Smart Contact Lenses for Continual Glucose Monitoring: A Review
Elsherif, M., Moreddu, R., Alam, F., Salih, A. E., Ahmed, I., & Butt, H. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2022.858784 · Cited by 64 · see citing works
Monitoring intraocular pressure for 24 h
Liu, J. H. K., & Weinreb, R. N. (2011) · British Journal of Ophthalmology · doi:10.1136/bjo.2010.199737 · Cited by 60 · see citing works
Tolerability of 24-Hour Intraocular Pressure Monitoring of a Pressure-sensitive Contact Lens
Lorenz, K., Korb, C. A., Herzog, N., Vetter, J. M., Elflein, H. M., Keilani, M. M., & Pfeiffer, N. (2013) · Journal of Glaucoma · doi:10.1097/ijg.0b013e318241b874 · Cited by 58 · see citing works
Laukhin, V., Sánchez, I., Moya, A., Laukhina, E., Martin, R., Ussa, F., Rovira, C., Guimera, A., Villa, R., Aguiló, J., et al. (2011) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2011.05.021 · Cited by 57 · see citing works
A new rebound tonometer for home monitoring of intraocular pressure
Rosentreter, A., Jablonski, K. S., Mellein, A. C., Gaki, S., Hueber, A., & Dietlein, T. S. (2011) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-011-1785-7 · Cited by 54 · see citing works
Polyimide/SU-8 catheter-tip MEMS gauge pressure sensor
Hasenkamp, W., Forchelet, D., Pataky, K. A., Villard, J., van Lintel, H., Bertsch, A., Wang, Q., & Renaud, P. (2012) · Biomedical Microdevices · doi:10.1007/s10544-012-9661-8 · Cited by 55 · see citing works
Self-citationSoft medical microrobots: Design components and system integration
Field, R. D., Anandakumaran, P. N., & Sia, S. K. (2019) · Applied Physics Reviews · doi:10.1063/1.5124007 · Cited by 54 · see citing works
Polymeric Materials for Eye Surface and Intraocular Applications
Karayilan, M., Clamen, L., & Becker, M. L. (2021) · Biomacromolecules · doi:10.1021/acs.biomac.0c01525 · Cited by 54 · see citing works
Continuous IOP Fluctuation Recording in Normal Tension Glaucoma Patients
Pajic, B., Pajic-Eggspuehler, B., & Haefliger, I. O. (2011) · Current Eye Research · doi:10.3109/02713683.2011.608240 · Cited by 53 · see citing works
Strain-rate sensitivity of porcine and ovine corneas.
Elsheikh, A., Kassem, W., & Jones, S. (2011) · PubMed · Cited by 53 · see citing works
Hubanova, R., Aptel, F., Chiquet, C., Mottet, B., & Romanet, J. (2014) · Acta Ophthalmologica · doi:10.1111/aos.12241 · Cited by 51 · see citing works
A contact lens promising for non-invasive continuous intraocular pressure monitoring
Pang, Y., Li, Y., Wang, X.-F., Chen-jie, Q., Yang, Y., & Ren, T.-L. (2019) · RSC Advances · doi:10.1039/c8ra10257k · Cited by 51 · see citing works
Prototype of a Nanostructured Sensing Contact Lens for Noninvasive Intraocular Pressure Monitoring
Sánchez, I., Laukhin, V. N., Moya, A., Martín, R., Ussa, F., Laukhina, E. E., Guimerà‐Brunet, A., Villa, R., Rovira, C., Aguiló, J., et al. (2011) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.10-7064 · Cited by 48 · see citing works
Nanomedicine for the treatment of retinal and optic nerve diseases
Zarbin, M. A., Montemagno, C. D., Leary, J. F., & Ritch, R. H. (2012) · Current Opinion in Pharmacology · doi:10.1016/j.coph.2012.10.003 · Cited by 47 · see citing works
Is 24-hour Intraocular Pressure Monitoring Necessary in Glaucoma?
Mansouri, K., Weinreb, R. N., & Medeiros, F. A. (2013) · Seminars in Ophthalmology · doi:10.3109/08820538.2013.771201 · Cited by 47 · see citing works
Self-tonometry in Glaucoma Management—Past, Present and Future
Liang, S. Y. ‐., Lee, G. A., & Shields, D. (2009) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2009.04.006 · Cited by 45 · see citing works
Advances in telemetric continuous intraocular pressure assessment
Kakaday, T., Hewitt, A. W., Voelcker, N. H., Li, J., & Craig, J. E. (2009) · British Journal of Ophthalmology · doi:10.1136/bjo.2008.144261 · Cited by 42 · see citing works
Wireless Communication and Power Harvesting in Wearable Contact Lens Sensors
Yuan, M., Das, R., McGlynn, E., Ghannam, R., Abbasi, Q. H., & Heidari, H. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3055077 · Cited by 42 · see citing works
Shinmei, Y., Nitta, T., Saito, H., Ohguchi, T., Kijima, R., Chin, S., & Ishida, S. (2016) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.16-19220 · Cited by 41 · see citing works
BioMEMS for medicine: On-chip cell characterization and implantable microelectrodes
Cheung, K. C., & Renaud, P. (2006) · Solid-State Electronics · doi:10.1016/j.sse.2006.03.023 · Cited by 40 · see citing works
Self-citation(2018) · Cambridge University Press eBooks · doi:10.1017/9781316286210.003 · Cited by 40 · see citing works
Estimation of 24-Hour Intraocular Pressure Peak Timing and Variation Using a Contact Lens Sensor
Liu, J. H. K., Mansouri, K., & Weinreb, R. N. (2015) · PLoS ONE · doi:10.1371/journal.pone.0129529 · Cited by 39 · see citing works
Hamzah, J. C., Daka, Q., & Azuara‐Blanco, A. (2019) · Eye · doi:10.1038/s41433-019-0669-7 · Cited by 39 · see citing works
Wearable Contact Lens Sensor for Non-Invasive Continuous Monitoring of Intraocular Pressure
Dou, Z., Tang, J., Liu, Z., Sun, Q., Wang, Y., Li, Y., Yuan, M., Wu, H., Wang, Y., Pei, W., et al. (2021) · Micromachines · doi:10.3390/mi12020108 · Cited by 38 · see citing works
Mansouri, K., Medeiros, F. A., & Weinreb, R. N. (2015) · Clinical and Experimental Ophthalmology · doi:10.1111/ceo.12567 · Cited by 37 · see citing works
Flow stabilization in wearable microfluidic sensors enables noise suppression
Araci, I. E., Ağaoğlu, S., Lee, J. Y., Yepes, L. R., Diep, P., Martini, M., & Schmidt, A. (2019) · Lab on a Chip · doi:10.1039/c9lc00842j · Cited by 37 · see citing works
Can the SENSIMED Triggerfish® lens data be used as an accurate measure of intraocular pressure?
Vitish‐Sharma, P., Acheson, A. G., Stead, R. E., Sharp, J. A. H., Abbas, A., Hovan, M., Maxwell‐Armstrong, C., Guo, B., & King, A. J. (2017) · Acta Ophthalmologica · doi:10.1111/aos.13456 · Cited by 35 · see citing works
Wu, K. Y., Mina, M., Carbonneau, M., Marchand, M., & Tran, S. D. (2023) · Micromachines · doi:10.3390/mi14101915 · Cited by 34 · see citing works
Meeting an unmet need in glaucoma: continuous 24-h monitoring of intraocular pressure
Mansouri, K., & Weinreb, R. N. (2012) · Expert Review of Medical Devices · doi:10.1586/erd.12.14 · Cited by 34 · see citing works
Tojo, N., Otsuka, M., Miyakoshi, A., Fujita, K., & Hayashi, A. (2014) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-014-2666-7 · Cited by 34 · see citing works
Cytokines and chemokines in immune-based ocular surface inflammation
Enríquez‐de‐Salamanca, A., & Calonge, M. (2008) · Expert Review of Clinical Immunology · doi:10.1586/1744666x.4.4.457 · Cited by 34 · see citing works
Fundamentals and Advances in Tonometry
Nuyen, B., & Mansouri, K. (2015) · Asia-Pacific Journal of Ophthalmology · doi:10.1097/apo.0000000000000118 · Cited by 33 · see citing works
High-sensitive microfluidic contact lens sensor for intraocular pressure visualized monitoring
Yuan, M., Liu, Z., Wu, X., Gou, H., Zhang, Y., Ning, X., Li, W., Yao, Z., Wang, Y., Pei, W., et al. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114250 · Cited by 33 · see citing works
Corneal thickness after overnight wear of an intraocular pressure fluctuation contact lens sensor
Freiberg, F. J., Lindell, J., Thederan, L., Leippi, S., Shen, Y., & Klink, T. (2012) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.2012.02495.x · Cited by 33 · see citing works
Evaluation of a Contact Lens-Embedded Sensor for Intraocular Pressure Measurement
Twa, M. D., Roberts, C. J., Karol, H. J., Mahmoud, A. M., Weber, P. A., & Small, R. H. (2010) · Journal of Glaucoma · doi:10.1097/ijg.0b013e3181c4ac3d · Cited by 32 · see citing works
State-of-the-Art in Smart Contact Lenses for Human–Machine Interaction
Xia, Y., Khamis, M., Fernández, F. A., Heidari, H., Butt, H., Ahmed, Z., Wilkinson, T., & Ghannam, R. (2022) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2022.3224683 · Cited by 34 · see citing works
Wearable dual-element intraocular pressure contact lens sensor
Karunaratne, I. K., Lee, C. H. C., Or, P. W., Wei, Y., Chong, I. T., Yang, Y., Yu, M., & LAM, D. C. C. (2021) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2021.112580 · Cited by 31 · see citing works
Pressure-Triggered Microfluidic Contact Lens for Ocular Drug Delivery
Du, Z., Zhao, G., Wang, A., Sun, W., & Mi, S. (2022) · ACS Applied Polymer Materials · doi:10.1021/acsapm.2c01118 · Cited by 31 · see citing works
A wireless intraocular pressure monitoring device with a solder-filled microchannel antenna
Varel, Ç., Shih, Y.-C., Otis, B. P., Shen, T. S., & Böhringer, K. F. (2014) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/24/4/045012 · Cited by 30 · see citing works
A capacitor-based sensor and a contact lens sensing system for intraocular pressure monitoring
Chiou, J., Huang, Y.-C., & Yeh, G. (2015) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/26/1/015001 · Cited by 30 · see citing works
A wearable contact lens sensor for noninvasive in-situ monitoring of intraocular pressure
Fan, Y., Tu, H., Zhao, H., Wei, F. H., Yang, Y., & Ren, T. (2020) · Nanotechnology · doi:10.1088/1361-6528/abca5f · Cited by 30 · see citing works
Current methods and new approaches to assess aqueous humor dynamics
Toris, C. B., Gagrani, M., & Ghate, D. A. (2021) · Expert Review of Ophthalmology · doi:10.1080/17469899.2021.1902308 · Cited by 30 · see citing works
Development of ciprofloxacin-loaded contact lenses using fluorous chemistry
Qin, G., Zhu, Z., Li, S., McDermott, A. M., & Cai, C. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.01.046 · Cited by 30 · see citing works
Noninvasive intraocular pressure monitoring: Current insights
De Smedt, S. (2015) · Clinical ophthalmology · doi:10.2147/opth.s53772 · Cited by 29 · see citing works
Faschinger, C., & Mossböck, G. (2010) · Der Ophthalmologe · doi:10.1007/s00347-010-2198-4 · Cited by 29 · see citing works
Wearable electronic devices for glaucoma monitoring and therapy
Zhang, W., Huang, L., Weinreb, R. N., & Cheng, H. (2021) · Materials & Design · doi:10.1016/j.matdes.2021.110183 · Cited by 27 · see citing works
An unpowered, wireless contact lens pressure sensor for point-of-care glaucoma diagnosis
Yan, J. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090698 · Cited by 27 · see citing works
Automated Detection and Quantification of Circadian Eye Blinks Using a Contact Lens Sensor
Gisler, C., Ridi, A., Hennebert, J., Weinreb, R. N., & Mansouri, K. (2015) · Translational Vision Science & Technology · doi:10.1167/tvst.4.1.4 · Cited by 27 · see citing works
Assessing Efficacy of Canaloplasty Using Continuous 24-Hour Monitoring of Ocular Dimensional Changes
Rękas, M., Danielewska, M. E., Byszewska, A., Petz, K., Wierzbowska, J., Wierzbowski, R., & Iskander, D. R. (2016) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.16-19185 · Cited by 26 · see citing works
New technologies for measuring intraocular pressure
Garcia-Sanchez, J., Martínez-de-la-Casa, J. M., Morales‐Fernández, L., Saenz-Frances, F., Santos-Bueso, E., García-Sáenz, S., & Mendez-Hernandez, C. D. (2015) · Progress in brain research · doi:10.1016/bs.pbr.2015.06.003 · Cited by 26 · see citing works
Aptel, F., Musson, C., Zhou, T., Lesoin, A., & Chiquet, C. (2016) · Journal of Glaucoma · doi:10.1097/ijg.0000000000000604 · Cited by 26 · see citing works
Split-ring resonator-based sensors on flexible substrates for glaucoma monitoring
Ekinci, G., Çalıkoğlu, A., Solak, S. N., Yalcinkaya, A. D., Dündar, G., & Torun, H. (2017) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2017.10.054 · Cited by 26 · see citing works
The importance of and potential for continuous monitoring of intraocular pressure
McMonnies, C. W. (2016) · Clinical and Experimental Optometry · doi:10.1111/cxo.12497 · Cited by 25 · see citing works
Advances and Challenges in Wearable Glaucoma Diagnostics and Therapeutics
Shean, R. S., Yu, N., Guntipally, S., Nguyen, V., He, X., Duan, S., Gokoffski, K. K., Zhu, Y., & Xu, B. Y. (2024) · Bioengineering · doi:10.3390/bioengineering11020138 · Cited by 25 · see citing works
- Authors
- Leonardi, M., Leuenberger, P., Bertrand, D., Bertsch, A., & Renaud, P.
- Affiliations
- École Polytechnique Fédérale de Lausanne (CH)
- Department of Ophthalmology, Hopita¯l Universitaire de Gene`ve, Gene`ve, Switzerland; and the
- Department of Physiology, Centre Me´dical Universitaire, Gene`ve, Switzerland.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2004-09-01
- Volume
- 45
- Issue
- 9
- Pages
- 3113
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2062231812
- Cited by
- 244
- References
- 22
- Citations by year
- 2026: 5 · 2025: 8 · 2024: 11 · 2023: 9 · 2022: 11 · 2021: 17 · 2020: 11 · 2019: 16 · 2018: 10 · 2017: 13 · 2016: 17 · 2015: 21 · 2014: 17 · 2013: 14 · 2012: 20
- FWCI
- 2.22
- Type
- journal article
- Language
- en
- Open access
- green
- infoscience.epfl.ch
- Locations
- Investigative Ophthalmology & Visual Science (publishedVersion)
- PubMed (publishedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Topics
- Health Sciences › Medicine › Ophthalmology › Glaucoma and retinal disorders
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Ocular Surface and Contact Lens
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal surgery and disorders
- Keywords
- intraocular pressure monitoring, strain gauges, corneal curvature, non-invasive pressure measurement, glaucoma management, porcine eyes, microfabricated sensors
- MeSH terms
- Animals, Contact Lenses, Intraocular Pressure, Monitoring, Physiologic, Swine, Tonometry, Ocular, Eye Enucleation, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review