The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Patterning piezoelectric thin film PVDF–TrFE based pressure sensor for catheter application
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sandham, J. D., Hull, R. D., Brant, R. F., Knox, L., Pineo, G. F., Doig, C. J., Laporta, D. P., Viner, S., Passerini, L., Devitt, H., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa021108 · Cited by 1,529
Flexible Dome and Bump Shape Piezoelectric Tactile Sensors Using PVDF-TrFE Copolymer
Li, C., Wu, P.-M., Lee, S., Gorton, A., Schulz, M. J., & Ahn, C. H. (2008) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2007.911375 · Cited by 245
Li, C., Wu, P., Shutter, L., & Narayan, R. K. (2010) · Applied Physics Letters · doi:10.1063/1.3299003 · Cited by 79
Thirty‐One Years of Clinical Experience with “Nuclear‐Powered” Pacemakers
Parsonnet, V., Driller, J., COOK, D., & Rizvi, S. (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00317.x · Cited by 49
Cited by
Trung, T. Q., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504244 · Cited by 2,160
Advances of flexible pressure sensors toward artificial intelligence and health care applications
Zang, Y., Zhang, F., Di, C.-A., & Zhu, D. (2015) · Materials Horizons · doi:10.1039/c4mh00147h · Cited by 1,272
Persano, L., Dagdeviren, C., Su, Y., Zhang, Y., Girardo, S., Pisignano, D., Huang, Y., & Rogers, J. A. (2013) · Nature Communications · doi:10.1038/ncomms2639 · Cited by 1,271
A review of piezoelectric polymers as functional materials for electromechanical transducers
Ramadan, K. S., Sameoto, D., & Evoy, S. (2014) · Smart Materials and Structures · doi:10.1088/0964-1726/23/3/033001 · Cited by 1,060
Piezoelectric Biomaterials for Sensors and Actuators
Chorsi, M. T., Curry, E. J., Chorsi, H. T., Das, R., Baroody, J., Purohit, P. K., Ilies, H., & Nguyen, T. D. (2019) · Advanced Materials · doi:10.1002/adma.201802084 · Cited by 865
Metadata
- Authors
- Sharma, T., Je, S.-S., Gill, B., & Zhang, J. X. J.
- Venue
- Sensors and Actuators A: Physical
- Publisher
- Elsevier BV
- Published
- 2012-04
- Volume
- 177
- Pages
- 87-92
- ISSN
- 0924-4247 (ISSN-L)
- OpenAlex
- W2036484700
- Cited by
- 316
- References
- 4
- FWCI
- 4.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.