Microwave reflective biosensor for glucose level detection in aqueous solutions
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This article presents the design and analysis of a real-time non-invasive microwave microfluidic sensor for measuring glucose concentration in aqueous solutions. The sensor is made of an open-ended microstrip transmission line loaded with a complementary split-ring resonator (CSRR). The CSRR shows a very intense electric field concentration at resonance, which is highly sensitive to the dielectric sample loading. A microfluidic channel is designed to deliver the glucose solutions to the sensitive area of the device. By applying liquid samples to the channel, a resonance frequency shift is detectable in the reflection coefficient (S11) of the device. This in turn leads to a change in the |S11|. Both of the frequency shift and Δ|S11| can be used to measure the glucose level in the solution. Mathematical models are developed based on the measurement results of the glucose-water solutions using the resonance frequency shift and Δ|S11|. The developed sensing models are then used for detecting the glucose levels down to physiological values using the designed biosensor. The results prove the potential compatibility of the proposed biosensor for human glycaemia monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement of tear glucose levels with amperometric glucose biosensor/capillary tube configuration
Yan, Q., Peng, B., Su, G., Cohan, B. E., Major, T. C., & Meyerhoff, M. E. (2011) · Analytical Chemistry · doi:10.1021/ac201700c · Cited by 185
Metadata
- Authors
- Ebrahimi, A., Scott, J., & Ghorbani, K.
- Venue
- Sensors and Actuators A: Physical
- Publisher
- Elsevier BV
- Published
- 2020-01
- Volume
- 301
- Pages
- 111662
- ISSN
- 0924-4247 (ISSN-L)
- OpenAlex
- W2988264568
- Cited by
- 223
- References
- 1
- FWCI
- 9.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microwave reflective biosensor for glucose level detection in aqueous solutions. https://app.cochat.ai/papers/10.1016/j.sna.2019.111662
- The paper
- Ebrahimi, A., Scott, J., & Ghorbani, K. (2020). Microwave reflective biosensor for glucose level detection in aqueous solutions. Sensors and Actuators A: Physical. https://doi.org/10.1016/j.sna.2019.111662
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.